Læs gratis den danske manual til Davis DAV-6470 (5 sider) i kategorien Temperaturregulator. Denne vejledning er vurderet som hjælpsom af 16 personer og har en gennemsnitlig bedømmelse på 4.9 stjerner ud af 8.5 anmeldelser. Har du et spørgsmål om Davis DAV-6470, eller vil du spørge andre brugere om produktet?

Side 1/5
1
Soil Moisture Sensor & Multi-Purpose Temperature
Probe Installation Instructions
For Wireless Leaf & Soil Moisture/Temperature Stations
The WATERMARK Soil Moisture Sensor and the Multi-Purpose Temperature
Probe are for use with the Vantage Pro2 Wireless Leaf & Soil Moisture/Temperature
Station, #6345. Please refer to your Wireless Leaf & Soil Moisture/Temperature
Station manual for more information on how to install and use the sensors.
Installation Procedures
Connecting the Sensors
To extend the sensor cables, see “Extending Sensor Cables” on page 4.
To use a temperature probe for temperature compensation of a soil moisture
sensor, install the sensor pair in corresponding connectors: 1 & 1, 2 & 2, 3 &
3, and 4 & 4.
If no soil temperature probe is used, the station will use a default temp of
75°F (24°C) to compensate the soil moisture readings.
If you are installing a temperature probe that is not providing temperature
compensation for a soil moisture reading, do not use a connector that matches
to any installed soil moisture sensor.
If a soil moister / temperature sensor pair do not use matching connectors, the
soil moisture reading can be off as much as 1% for every 1
° °F (0.5 C) error in
the soil temperature.
1. Run the sensor cables up through the grommets on the bottom of the station
housing.
2. Connect soil moisture probes to the SOIL connectors.
3. Connect the temperature probes to the TEMP connectors.
Cable Clam
p
Mount
Leaf Wetness
Sensor Cable
Rubber
Grommets
SENSOR
SENSOR
SENSOR
SENSOR
SENSOR
INTERFACE
INTERFACE
INTERFACE
INTERFACE
INTERFACE
MODULE
MODULE
MODULE
MODULE
MODULE
Cable Clamp
Cable Clam
p
Screw
Temperature Moisture
1 2 3 4 1 2 3 4
Soil Moisture
Sensor Cable
Temperature
Probe Cable
Sensor Cables Enter Station
Housing Through Grommets
Connecting Sensor Cable to
Terminal Block


Produkt Specifikationer

Mærke: Davis
Kategori: Temperaturregulator
Model: DAV-6470

Har du brug for hjælp?

Hvis du har brug for hjælp til Davis DAV-6470 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Temperaturregulator Davis Manualer

Davis

Davis DAV-6470 Manual

24 August 2024

Temperaturregulator Manualer

Nyeste Temperaturregulator Manualer

Inkbird

Inkbird ITC-308-WIFI Manual

30 September 2025
Inkbird

Inkbird ITC-306T-WIFI Manual

29 September 2025
Gossen Metrawatt

Gossen Metrawatt R6000 Manual

26 September 2025
Emko

Emko ESM-9420 Manual

7 September 2025
SRS

SRS PTC10 Manual

3 September 2025
Fluke

Fluke 1504 Manual

2 September 2025
Daikin

Daikin KRCS01-8B Manual

11 August 2025
Daikin

Daikin BRC4C61 Manual

11 August 2025