PROG
AUTO
TYBOX
0h 2 4 6 8 10 1 2 14 1 6 18 20 22 2 4
1234567
i
P
R
OG
AUTO
h
2 4
6
8
10
1
2 1
4
16
18 20
22
24
TYBOX 610
Weekly programmable thermostat
Installation guide
DELTA DORE - Bonnemain
35270 COMBOURG - FRANCE
E-mail: deltadore@deltadore.com
- 2 -
Warnings Contents
Carefully read these instructions prior to installation.
The unit must be installed in compliance with current standards.
Always switch off the mains before installing or servicing the unit.
Do not attempt to repair the unit yourself; an after-sales service is available.
Check that the fastenings are suited to the surface to which the unit will be attached
(plasterboard, brick, etc.).
The diagrams provided have been simplified for greater clarity. Protections and other
accessories required by standards are not illustrated. The UTE NF C15-100 standard
and industry best practices must be complied with. Connected or nearby units must
not generate excessive interference (directive 2004/108/EC).
- 3 -
Fitting the thermostat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Connecting a boiler with thermostat input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Connecting a boiler without thermostat input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Controlling electric convectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Controlling a heat pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Activation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Correcting the temperature measured . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Automatic mode temperature display option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Setting the comfort temperature in heating mode . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Air conditioning function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Circulator anti-seizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Control time base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Restoring factory settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Summary table of configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Technical features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
- 5 -- 4 -
Fitting the thermostat
We recommend that you install your device:
- where there is easy access, such as a corridor, living room or entrance hall,
- on an interior wall at a height of 1.50m from the floor
Your appliance will also show you
the room temperature.
It is therefore recommended that
it be installed well removed from
any sources of heat (e.g. convec-
tors, chimney) and draughts (e.g.
doors, windows).
1
2
Remove the protective tab from the batteries.
Open the thermostat housing by pressing on clip
Unscrew the locking screw on the protective cover of the
connecting terminal box.
Mount the base using suitable screws and screw anchors or
fit into a flush-mounted box.
3 3
approx.
1.50 m
Partitions (mark ) that can
be removed with pliers
enable connecting wires to
be used, if required.
- 6 -
Connections
Connect receiver terminals 1 and 3 to both termi-
nals of the boiler thermostat input.
If necessary, remove the shunt connecting the
two thermostat input terminals.
If the boiler has a clock input, do not mistake it for
the thermostat input.
Connecting a boiler with thermostat input
1
2
3
- 7 -
Connect the control wires
(see the section on
Connections) and screw
back in the locking screw
for the protective cover
Fitting the batteries
Insert 2 LR03 1.5 V alkaline
batteries, making sure to
respect the battery polari-
ties.
Never use rechargeable
batteries.
Use only alkaline batteries.
Click
Reposition the front
cover of the thermostat
and push until it clicks
into place
thermostat
boiler
boiler thermostat
input
do not confuse with
the clock input (on
some boiler models)
wires to be
connected to the
thermostat
remove the
shunt
Example of a boiler
terminal box
- 9 -
1
2
3
1
2
3
1
2
3
Controlling a heat pump
Select cabling that is suitable for your heat pump or refer directly to the manufacturer's
specifications.
N
N
L
L
1
2
3
Controlling electric convectors
To control electrical convectors, you MUST
use a power contact switch that is suitable
for the total power to be controlled.
This power contactor switch must be fitted
into the electrical switchboard of your home.
- 8 -
Connecting a boiler without thermostat
input
If the boiler does not have a thermostat
input, you can directly control the circula-
tor which is located next to the boiler (the
pump enabling circulation of the hot water
into the radiators).
- Directly control the power supply to the
circulator using the thermostat.
N
L
1
2
3
thermostat
circulator
mains power
230 V/50 Hz
mains power
230 V/50 Hz
thermostat
power supply of
the contact
switch coil
contact switch (not supplied)
fitted in the electrical
switchboard
convector(s)
Heat pump
with thermostat input
and summer / winter Input
Heat pump
with thermostat heat input
and thermostat cool input
Heat pump
with thermostat input
and Summer / winter switch
Hydraulic kit Hydraulic kit Hydraulic kit
Underfloor
heating
output Summer /
winter switch
Underfloor
heating
output
Underfloor
heating
output
Summer /
winter switch
Geothermal OR Air source Geothermal OR Air source Geothermal OR Air source
Thermostat
input Thermostat
input
Summer /
winter switch
Summer /
winter Input
Thermostat
heat input
Commun
Thermostat
cool input
winterSummer
- 11 -
Configuration
To access the configuration menus, turn the knob to the position marked
Press OK to access menu CF01
The reference number of your device is displayed as well as the version number
- 10 -
Activation
Turn the knob to the position
The day numbers flash.
Press + or - to set the day, then
OK to confirm and go to the next
setting.
Repeat these steps to set the hours and minutes.
To exit the “time setting” mode, turn the selector knob.
Days
Hours Minutes
(1: Monday
7: Sunday)
Unit
reference
number
Unit version
(e.g.: 1.00)