Læs gratis den danske manual til Deltronic 32-8625 (1 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 28 personer og har en gennemsnitlig bedømmelse på 4.9 stjerner ud af 14.5 anmeldelser. Har du et spørgsmål om Deltronic 32-8625, eller vil du spørge andre brugere om produktet?

Side 1/1
32-8625 NARCOTIC GAS ALARM MANUAL
The gas alarm requires 2-3 minutes to warm up whenever it is powered up. During this period
the gas alarm may not respond (no alarm) to gas or a push-button test.
PLACEMENT
We recommend you to install the narcotic gas alarm close to where you sleep, or suspect the
gas to be dispersed from since most narcotic gases generally mixes well with air. This detec-
tor has been designed to detect primarily narcotic gas (Diethyl Ether etc.), which provokes
sleepiness and incapability to react as it inhibits some cerebral functions. The detection is
smoke, perfume etc. Please note that this alarm does not sense the presence of carbon monox-
ide (CO gas).
INSTALLATION
This gas alarm is design for easy and exible installation and comes complete with screws,
mounting bracket and cable/adaptor. Attach the mounting bracket to wall with the screws
provided then twist and lock the alarm into place (clockwise). Now plug alarm into a 12VDC
cigarette lighter receptacle using provided car adaptor or use the provided cable for a more
permanent installation. When the alarm is properly installed, green LED indicates the alarm
is receiving sufcient power and red LED ashes once per minute indicating proper opera-
tion. Wait for 2-3 minutes, then push and hold the test button for 5-10 seconds. If the alarm is
activated the unit is now ready to detect and protect.
AL TIGNMEN
MARKS
TESTING AND MAINTENANCE
Test alarm by using the test button at least once a week and always after long absences. Check
that the green light diode is active, indicating sufcient current supply. Also check that the
red light diode ashes every 40 seconds. Then press and hold the test button until the alarm
sounds. A simple condence check can be conducted by using a small disposable cigarette
lighter and pressing the lever normally used to maintain the ame without lighting it. If this is
then held close to the alarm, the red LED light will come on and the alarm will sound. Make
sure to air out the room after testing.
Vacuum unit regularly and use a cloth
to wipe the outside of the alarm. When
used in for example boats, caravans,
mobile homes etc. we recommend that
you store the gas alarm in normal room
temperature during the winter season,
this prolongs its life expectancy. A gas
alarm should be replaced after around 5
years, because the gas sensor thereafter
gradually changes sensitivity.
GAS SAFETY - GENERAL ADVICE
If alarm sounds, open all windows and doors to allow the gas to disperse. Don’t switch on/
off lighting, exhausting fan or any kind of electrical appliance to avoid explosion. Check all
the gas appliances, extinguish any open ames including cigarettes and turn off the gas supply
and check hose connectors and pipes for leakages. It’s crucial that the source(s) of the leak
is determined and appropriate repairs are made. Contact the supplier of the gas equipment or
the re brigade if the problem is not located. In case of immediate danger, always call the re
brigade from outside the building.
When leaving the room where the gas is used, always turn off any equipment and the gas
supply.
Do not make any changes in the gas installation without proper knowledge.
Let a specialist inspect your gas installations regularly.
Avoid sleeping in direct proximity to the gas installations.
GUARANTEE
We guarantee your new gas alarm for two years from the date of purchase by the end user; the
guarantee is limited to replacement of the product, repair of the product or replacement of the
product with repaired product at the discretion of the manufacturer.
We shall be under no obligation to repair, replace or refund units which are found to be
defective in any way due to unreasonable use or neglect, been tampered with, and modied or
subject to attempted repairs or exposed to extreme temperatures.
Ver. 080828
12V DC
PLUG IN
ALT.
PLUG IN
CIGARETTE LIGHTER
ADAPTOR
12V DC
POWER SOURCE


Produkt Specifikationer

Mærke: Deltronic
Kategori: Ikke kategoriseret
Model: 32-8625

Har du brug for hjælp?

Hvis du har brug for hjælp til Deltronic 32-8625 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Deltronic Manualer

Deltronic

Deltronic 32-8625 Manual

29 August 2024
Deltronic

Deltronic COG8 Manual

29 August 2024
Deltronic

Deltronic GLN 221 Manual

29 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer