Læs gratis den danske manual til Doepfer A-143-2 (6 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 7 personer og har en gennemsnitlig bedømmelse på 5.0 stjerner ud af 4 anmeldelser. Har du et spørgsmål om Doepfer A-143-2, eller vil du spørge andre brugere om produktet?

Side 1/6
DOEPFERDOEPFERDOEPFERDOEPFER System A-100 Quad ADSR A-143-2
1
Fig. 1: A-143-2 Controls, Inputs and Outputs
1. Introduction
Module A-143-2 contains four independent ADSR-type
envelope generators. Each sub-unit has available the
controls Attack, , Decay Sustain and Release. The three-
position Range switch allows selection of the desired time
range (low - high - medium). The adjustable envelope time
ranges from several minutes to less than 100 microseconds.
On top of this each unit is equipped with three digital outputs
(high/low): "End of Attack (EOA)", "End of Decay (EOD)"
and "End of Release (EOR)". As soon as the criterion is
valid (e.g. end of decay state) the corresponding digital
outputs turns "high". These outputs can be used e.g. to
daisy-chain several ADSR units. For this the digital output in
question (EOA, EOD or EOR) has to be connected to the
Gate input of the following ADSR. Even automatically
running envelopes (pseudo LFOs) or so-called "quadrature
envelopes" with cyclical modulations of several ring-shaped,
daisy-chained ADSRs are possible.
In addition to the obligatory Gate (G) input for envelope
generators each unit has available a Retrigger (Rt) input.
The retrigger turns the direction to "upward" if the envelope
has already reached the decay state while the retrigger
pulse occurs. The Gate inputs 2, 3 and 4 are normalled to
Gate input 1, i.e. the Gate input 1 is connected to the
switching contacts of the other inputs. Thus only one Gate
signal at Gate input 1 can be used to trigger all four units
simultaneously.
The envelope outputs are displayed with LEDs.
Quad ADSR A-143-2 System A-100 DOEPFERDOEPFERDOEPFERDOEPFER
2
2. Basic Principles
Fig. 2 shows the basic function of each unit:
Fig. 2: Basic function
The positive edge of the gate input starts the envelope
signal and resets both the End of Attack (EOA)and "End
of Release (EOR)" output. The time required to reach the
maximum value of the envelope is defined by the attack
control. As soon as the envelope level reaches the sustain
level during the rising slope, the digital "End of Decay
(EOD)" output turns low. As the maximum value (about +8
V) is reached, the EOA output turns “high” and the so-called
Decay phase begins. In the decay phase the slope falls to
the Sustain level defined by the sustain control with a time
adjusted by the decay control. At the end of the decay
phase the envelope output remains at the sustain level until
the gate signal turns low. When the gate signal turns low the
EOD output turns high and the Release phase of the
envelope begins. The slope falls to zero with a time adjusted
by the release control. When the envelope level reaches
about +0.5V the EOR output turns high.
The retrigger behaviour of the A-143-2 is different compared
to other envelope generators. During the attack phase the
envelope cannot be retriggered or reset. During the decay
phase the envelope direction changes if a positive edge
appears at the retrigger input (i.e. the envelope changes
from decay to attack state).
Fig. 3: Retrigger behaviour


Produkt Specifikationer

Mærke: Doepfer
Kategori: Ikke kategoriseret
Model: A-143-2

Har du brug for hjælp?

Hvis du har brug for hjælp til Doepfer A-143-2 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Doepfer Manualer

Doepfer

Doepfer A-100 Manual

1 September 2024
Doepfer

Doepfer Dark Link Manual

21 August 2024
Doepfer

Doepfer A-196 Manual

20 August 2024
Doepfer

Doepfer A-134 Manual

20 August 2024
Doepfer

Doepfer A-135-2v Manual

19 August 2024
Doepfer

Doepfer A-145 Manual

19 August 2024
Doepfer

Doepfer A-101-2 Manual

19 August 2024
Doepfer

Doepfer A-99 Manual

19 August 2024
Doepfer

Doepfer A-103 Manual

19 August 2024
Doepfer

Doepfer A-165 Manual

18 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer