ES 100 Power Supply 
 
24 Volt D.C. Power Supply 
 
General: 
The ES 100 Power Supply is a general purpose power supply providing 24 volt, 
full wave filtered DC power at a continuous current rating of 1.3 amps. 
 
Zones: 
The ES 100 contains as a standard feature two (2) zone capability. Each zone has 
one (1) set of control input terminals and one (1) set of output terminals. The 1.3 
amp output rating is applied to either zone as long as the continuous current draw 
does not exceed 1.3 amps (Example zone #1 may draw 1.0 amps however zone #2 
may not exceed 0.3amps. If zone #2 is not used then zone #1 is rated at 1.3 amps 
continuously. The control input may be used as either a dry contact or voltage 
input.   
 
Operation: 
Trigger input of the ES 100 Power supply will occur by a switch and/or relay. A 
Dry Contact input refers to a switch or relay contact that provides no external 
voltage to activate the Power Supply. Contacts can be either normally open 
contacts or normally closed contacts. These input contacts are connected to 
terminals #3 & #4 for zone #1 and terminals #7 & #8 for zone #2. Normally Open 
Contacts are use when the ES 8000 Series Exit Device is used in conjunction with 
this Power Supply. Normally Close Contacts are used when the DE9000 Delayed 
Egress Exit Device is used in conjunction with this Power Supply. A fire alarm 
system can be used as the normally open or normally closed contact to trigger the 
ES 8000 Series Exit Device or give constant power to the DE9000 Series Delayed 
Egress Exit Device. DORMA recommends using the normally closed contacts of 
the building’s fire alarm system to control the power being supplied to the 
DE9000 Delayed Egress Exit Device from the ES100 Power Supply. 
 
Voltage input refers to an external source of 24 VDC power required to activate 
the output terminals. To use zone #1 as a Voltage Input, connect the control 
voltage positive (+) wire to terminal #3 and the voltage negative (-) wire to 
terminal #2. The external source voltage must have a current rating of 0.045 amps 
per zone. Connect the output device such as ES8000 Series Exit Device with 
Electric Latch Retraction and DE9000 Series Delayed Egress Exit Device to 
terminals #1 and #2. When control voltage is present it will power the output 
terminals. To use zone #2 as a Voltage Input, connect the control voltage positive 
(+) wire to terminal #7 and the voltage negative (-) wire to terminal #6. The 
external source voltage must have a current rating of 0.045 amps per zone. 
Connect the output device such as ES8000 Series Exit Device with Electric Latch