Dormakaba RCI 8375 Manual


Læs gratis den danske manual til Dormakaba RCI 8375 (4 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 15 personer og har en gennemsnitlig bedømmelse på 4.0 stjerner ud af 8 anmeldelser. Har du et spørgsmål om Dormakaba RCI 8375, eller vil du spørge andre brugere om produktet?

Side 1/4
INSTALLATION
RCI 8375
SURFACE MICROMAG® ELECTROMAGNETIC LOCKS
© 2020 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: sales_RCI@dormakaba.com
IS8375
PCN18041
R03-20GR-1
Pre-Installation Instructions
1. This product must be installed according to all applicable building
and life safety codes.
2. Due to the variety of mounting configurations available with this
product, a survey and assessment of the physical area in which
the product will be installed must be performed.
3. The door frame must be inspected and deemed structurally sound
prior to installation of the electromagnetic lock. The structural
integrity of the mounting surfaces must be strong enough to meet
or exceed the holding force of the product.
4. The product must be protected from potential damage due to
intruders or tampering.
5. The product should be installed in a location that will not hinder
or create a potential safety hazard to authorized personnel
accessing the protected area.
6. Because electromagnetic locks are used in a variety of applications
and different door frame configurations, an experienced installer
with knowledge of this product must make a determination of the
optimal mounting method for this specific application.
7. The components, hardware, installation instructions and mounting
template included with this product are intended for use on
outswinging doors.
8. Do not install this product on the exterior of buildings.
9. Do not use as a doorstop. This will void warranty.
10. Separate accessories not included with this product must be used
in the following applications:
Inswinging doors
Narrow head jamb situations or center-hung doors
Wherever there is insufficient space on the door
frame header to mount the lock
Glass or Herculite doors that do not have a door frame
Hollow metal or wood frames where the door stop is
not thick enough to allow the product to be installed
Wherever an obstruction in the door prevents
installation of the armature plate at a proper height
Doors that do not permit the armature plate to be
mounted low enough to meet the magnet surface
Refer to the page 4 Product Accessories Guide for further
information. Accessories may impact holding force.
11. Installation of this product should be done by an experienced
installer with knowledge of this product.
NOTE: It is highly recommended that thread locking compound be
applied to all screws during installation to reduce chance of screws
loosening over extended time.
PLEASE DELIVER ALL INSTALLATION INSTRUCTIONS TO
THE END-USER UPON COMPLETION OF THE INSTALLATION.
Fig. 1.
8375 Mounting
Plate Removal
Fig. 2 8375 Voltage Selection Jumper Setting
12VDC Operation 24VDC Operation
(Factory Setting)
Electromagnetic lock installations must conform to local fire codes, National
building codes and Life Safety Codes.
Mounting
Bracket
Releases captive
mounting screws
NOTE: All dormakaba electromagnetic locks must be powered with
filtered and regulated DC power supplies such as the DKPS Series UL
Listed power supply. dormakaba offers a full line of power supplies and
switching devices that are suitable for use with the 8375 Series locks.
To Ensure Instant Release All switching devices must be wired in
between the DC power source and the positive terminal of the lock in
Fig 3.
Switching the negative power supply line will not allow the lock to
release immediately. dormakaba electromagnetic locks contain MOV’s
for surge suppression and do not require any additional suppression to
be added during installation. The installation of diodes across the lock
input terminals will cause a delay in release.
Fig. 3 Power Connections
SWITCH
+
-
INCORRECT
CORRECT
+
-
SWITCH
FILTERED DC SUPPLY
FILTERED DC SUPPLY
Mount the electromagnetic lock to the door frame as outlined on the
installation template included with the product.
NOTE: During installation of the armature plate to the door it is essential
that the armature plate remains movable. The armature plate must be
allowed to pivot on the center-mounting bolt to allow proper alignment with
the magnet surface. If the plate is not aligned with the magnet surface, the
lock may lose holding force or not lock at all.
The head of the armature mounting bolt ships with a rubber washer affixed
to it. This washer should project slightly beyond the surface of the armature
plate. This is to allow the washer to expand when power is removed and
break the air vacuum between the plate and the magnet surface. If this
washer is removed or trimmed the lock will appear to have some holding
force even when power is removed.
For added safety, thread locking compound has been provided for the armature
plate bolt and the four captive electromagnetic lock mounting screws.
WARNING: Improper installation, maintenance, inspection or usage
of the product or any related accessories or parts may cause the
electromagnetic lock, armature plate and associated hardware to
disengage and fall, causing serious bodily injury and property damage.
dormakaba Canada Inc. and/or dormakaba USA Inc. will not be liable to
the installer, purchaser, end user or anyone else for damage or injury to
person or property due to improper installation, care, storage, handling,
maintenance, inspection, abuse, misuse or act of God or nature involving
this product or any related accessories or parts.
Route the power supply connecting wire through the door frame and into the
wire access hole in the top of the magnet housing. Connecting wire should
be of sufficient gauge for the lock being installed and the distance being run.
Installation Instructions
Inspection and Maintenance
This product and all related accessories or parts must be inspected
and maintained on a . Contacting surfaces of quarterly basis
the electromagnetic lock and armature plate must be kept free of
contaminating materials. Surfaces must be cleaned periodically with a
non-abrasive cleaner.
All mounting fasteners must be inspected on a quarterly basis.
When properly installed, the ends of the armature plate allow a slight
movement but the plate will feel secure when grasped at the bolt. There
should be no movement to the mounting bracket or housing of the
electromagnetic lock.
For added safety, thread locking compound has been provided for the
armature plate bolt and the four captive electromagnetic lock mounting
screws.
WARNING: Improper installation, maintenance, inspection or usage
of the product or any related accessories or parts may cause the
electromagnetic lock, armature plate and associated hardware to
disengage and fall, causing serious bodily injury and property damage.
PLEASE DELIVER ALL INSTALLATION INSTRUCTIONS TO THE
END-USER UPON COMPLETION OF THE INSTALLATION.
2


Produkt Specifikationer

Mærke: Dormakaba
Kategori: Ikke kategoriseret
Model: RCI 8375

Har du brug for hjælp?

Hvis du har brug for hjælp til Dormakaba RCI 8375 stil et spørgsmål nedenfor, og andre brugere vil svare dig