Dri-Eaz DriForce Manual
Dri-Eaz
Varmeapparat
DriForce
Læs nedenfor 📖 manual på dansk for Dri-Eaz DriForce (14 sider) i kategorien Varmeapparat. Denne guide var nyttig for 31 personer og blev bedømt med 4.7 stjerner i gennemsnit af 16 brugere
Side 1/14

07 00274- L F211, F211-AK, F211- 1 Legend Brands, Inc. BU
Owner’s Manual
DriForce™ InterAir Drying System
Models , F211-AK, F211- F211 BU
Legend Brands, Inc.
15180 Josh Wilson Road, Burlington, WA 98233
Phone: 800- -3030 Fax: 360- -7950 932 757 LegendBrandsRestoration.com
The DriForce InterAir Drying System allows the restorer to direct high-pressure air into wet walls,
behind cabinets, and into other hard- -reach structures with minimal disruption to materials. to
Provides fast, eective drying in all types of assemblies and materials.
Patents: www.LBpatents.com
R E A D A N D S A V E T H E S E I N S T R U C T I O N S
WARNING! To reduce the risk of re or electric shock, do
not use this fan with any solid-state speed control device.
WARNING! Unit must be grounded. Do not use with an ex-
tension cord. Connect only to an outlet provided with a
ground fault interrupting device.
WARNING! Do not touch grills when unit is operating.
NOTICE: Keep motor dry. For indoor use only.
NOTICE: Unplug when not in use or when moving unit.
WARNING: Do not allow children to play with or around the
unit. Be sure the unit is inaccessible to children when not
attended.
NOTICE: Always operate the unit on a stable, level surface
so it cannot fall and cause injury.
WARNING! Do not alter or modify your Dri-Eaz product in
any way. Use only replacement parts authorized by Legend
Brands Restoration, Inc. Modications or use of unapproved
parts could create a hazard and will void your warranty. Con-
tact your authorized Dri-Eaz distributor for assistance.
WARNING!
a) Do not operate any fan with a damaged cord or plug. Dis-
card fan or return to an authorized service facility for exami-
nation and/or repair.
Manifolds (×8)
Hose barbs (×5)
Crush-proof
hose (thirteen
7 ft./2 m sec-
tions)
Carry bags (×2)
DriForce muf-
er/lter
DriForce unit
Manifold T-con-
nectors (×2)
ADS tubing
(91 ft.)
Injectors (×100)
Manifold
endcaps (×4)
DRIFORCE AIR DRYING SYSTEM (ADS) COMPONENTS
WARNING
WARNING
WARNING
WARNING WARNING

07 00274- L F211, F211-AK, F211- 2 Legend Brands, Inc. BU
b) Do not run cord under carpeting. Do not cover cord with
throw rugs, runners, or similar coverings. Do not route cord
under furniture or appliances. Arrange cord away from trac
area and where it will not be tripped over.
WARNING: This product and other substances
that may become airborne from its use contain
chemicals, including lead and phthalates, known to
the State of California to cause cancer, birth defects, or
other reproductive harm. For more information, go to
P65Warnings.ca.gov
BEFORE YOU BEGIN
Warranty registration
Please visit to register your purchase. warranty.drieaz.com
Registration allows us to better assist you with using, main-
taining or servicing your equipment and to contact you in
case we have important safety information concerning your
Dri-Eaz product. If you determine service is required, have
your equipment model, serial number and original proof of
purchase available and call your distributor for assistance
with obtaining a return material authorization (RMA).
OPERATING INSTRUCTIONS
IMPORTANT: Extract standing water before attempting
to dry. Do NOT use the DriForce to extract standing wa-
ter of any kind.
Tools
Pencil, tape measure, razor knife, drywall taping knife,
small pry bar, nail puller, screw driver, a carpet awl, a drill
with a 3⁄16 bit. An electronic stud nder is also useful. in.
Preparing Walls, Cabinets and other As-
semblies for Drying
Walls
Wall drying using an inter-air drying system can be accom-
plished with or without baseboards present. After inspect-
ing walls, insulation, and baseboards, and after evaluating
paint nish considerations, proceed in the manner that de-
livers the most value to the customer.
Remove baseboard or cove base. First, use a razor knife to
score along the top of the base where it meets the wall, to
reduce damage to the painted surfaces and make a profes-
sional re-installation easier. When prying base away from
the wall, protect the wall surface by inserting a drywall
knife between the pry bar and the wall. Pull remaining
nails out of the wall, or through the back of the base-
board. Write a number on the wall and the corre-
sponding base so you will know where to reinstall it.
However, drying success can also be achieved by
making the wall penetrations immediately above the
top of baseboard and proceeding to dry with the base-
boards in place. This a necessary procedure where
there is a desire to save a wall with a tiled wall base,
when value is added by avoiding the detachment of
wall baseboards.
Making air access holes
Punch holes with a carpet awl use a drill with a or
3⁄16 bit. Create at least one hole between each set in.
of studs and about 2 in. above the oor. An electronic
stud nder can be used to locate studs and nd the
center of the cavity .
Larger holes are more time-consuming to patch, and may
decrease eciency by leaking air. Try to reduce the need
for later repairs by placing the holes behind the rubber
wainscoting or cove base, or behind trim that is easily rein-
stalled over the holes.
Steel Studs
Steel studs are common in commercial buildings. They are
set in a channel that can hold large volumes of water. To
access these areas, drill holes approximately ½ inch from
The DriForce and the Air Drying System can deliver air to struc-
tural cavities in walls, ceilings, under and above cabinets, and
many other areas.
The ADS connects to the DriForce blower outlet and attaches
to a manifold with a standard hose cu. Supply tubes run from
the manifold to injectors that are inserted into a wall or other
structural cavity.
ON/OFF
switch in
base (not
shown)
DRIFORCE BLOWER
Vacuum IN
Blower OUT
Wrap cord
around unit
when not in
use.
Produkt Specifikationer
Mærke: | Dri-Eaz |
Kategori: | Varmeapparat |
Model: | DriForce |
Har du brug for hjælp?
Hvis du har brug for hjælp til Dri-Eaz DriForce stil et spørgsmål nedenfor, og andre brugere vil svare dig
Varmeapparat Dri-Eaz Manualer

23 August 2024

20 August 2024

18 August 2024

17 August 2024

17 August 2024

16 August 2024

16 August 2024
Varmeapparat Manualer
- Varmeapparat Bestway
- Varmeapparat Jata
- Varmeapparat Cuisinart
- Varmeapparat Heidenfeld
- Varmeapparat AEG
- Varmeapparat Kent
- Varmeapparat Barbecook
- Varmeapparat Emerio
- Varmeapparat InfraNomic
- Varmeapparat Perel
- Varmeapparat Kogan
- Varmeapparat Fluval
- Varmeapparat Aduro
- Varmeapparat AustWood
- Varmeapparat VOX
Nyeste Varmeapparat Manualer

12 Juni 2025

12 Juni 2025

12 Juni 2025

12 Juni 2025

12 Juni 2025

12 Juni 2025

12 Juni 2025

12 Juni 2025

12 Juni 2025

12 Juni 2025