Side 1/7
Eastron SDM120-CTM User Manual
Zhejiang Eastron Electronic Co.,Ltd. Tel: 0086-573-83698881 Fax: 0086-573-83698883
Add: No.1369 Chengnan Road, Jiaxing, Zhejiang, 314001, China. Web: www.eastron.com.cn Email: sales@eastrongroup.com
SDM120CTM
Single-Phase Multifunction DIN Rail Meter
Measures kWh, kVArh, kW, kVAr, kVA, PF, Hz, dmd, V, A, etc.
Bi-directional measurement IMP & EXP
Two pulse outputs
Din rail mounting 35mm
1A or 5A CT connection
Better than Class 1 accuracy
User Manual V1.2
Eastron SDM120-CTM User Manual
Zhejiang Eastron Electronic Co.,Ltd. Tel: 0086-573-83698881 Fax: 0086-573-83698883
Add: No.1369 Chengnan Road, Jiaxing, Zhejiang, 314001, China. Web: www.eastron.com.cn Email: sales@eastrongroup.com
Application
The energy-meters are used to measure single-phase applications like residential, utility and Industrial. The unit
measures and displays various important electrical parameters. It equipped with a white back-lighted LCD screen
for prefect reading. As well as a RS485 communication port for remote reading and monitoring. Bi-directional
energy measurement makes it a good choice for solar PV energy metering. The compact design and din rail
installation provides an easy and economical solution for your metering demand.
PART 1 Specification
General Specifications
Voltage AC (Un) 230V
Voltage Range 176~276V AC
Base Current (Ib) 5A
Power consumption <2W/10VA
Frequency 50/ 60Hz(±10%)
AC voltage withstand 4KV for 1 minute
Impulse voltage withstand 6KV-1.2uS waveform
Overcurrent withstand 20Imax for 0.5s
Pulse output 1 0.001/0.01/0.1/1 kWh/imp (configurable)
Pulse output 2 1000imp/kWh (default)
Display LCD with white backlit
Max. Reading 999999 kWh
Accuracy
Voltage 0.5% of range maximum
Current 0.5% of nominal
Frequency 0.2% of mid-frequency
Power factor 1% of Unity
Active power 1% of range maximum
Reactive power 1% of range maximum
Apparent power 1% of range maximum
Active energy Class 1 IEC62053-21
Class B EN50470-1/3
Reactive energy Class 2 IEC62053-23
Environment
Operating temperature -25 to +55
Storage and transportation temperature -40 to +70
Reference temperature 23 2℃±