Emos MD-510 Manual
Emos
Multimeter
MD-510
Læs gratis den danske manual til Emos MD-510 (72 sider) i kategorien Multimeter. Denne vejledning er vurderet som hjælpsom af 24 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 12.5 anmeldelser. Har du et spørgsmål om Emos MD-510, eller vil du spørge andre brugere om produktet?
Side 1/72

2202018000_31-M3252_00_01 90 × 180 mm
M3252 | MD-510
GB Digital Multimeter
CZ Digitální multimetr
SK Digitálny multimeter
PL Multimetr cyfrowy
HU Digitális multiméter
SI Digitalni multimeter
RS|HR|BA|ME Digitalni multimetar
DE Digitales Multimeter
UA Цифровий мультиметр
RO Multimetru digital
LT Skaitmeninis multimetras
LV Digitālais multimetrs
EE Digitaalne multimeeter
BG Цифров мултиметър
www.emos.eu
1
23
1

2
GB | Digital Multimeter
Read this instruction manual thoroughly before you begin using the MD-510. It contains
particularly important passages concerning occupational safety principles when using the
device. Such passages are highlighted. Reading the manual will prevent potential injury
by electric current or damage to the device. The multimeter was designed in accordance
with standard IEC-61010 which applies to electronic measuring devices within category
CAT III 600 V, pollution degree 2. The CAT III category is used to measure circuits powered
by a xed output power supply, such as a relay, socket, switchboards, power supplies,
short branching circuits and lighting systems in large buildings.
Warning
Use the MD-510 multimeter only in the manner specied below. Other uses may cause
damage to the device or injury to your health. Comply with the following instructions:
• Before measuring resistance, diodes or current, disconnect the circuits from power
supply and discharge high-voltage capacitors. Use the corresponding function for
the given measurement. Before pressing the SELECT button to change functions,
disconnect the testing conductors from the tested circuit.
• Make sure the device is undamaged before you begin using the multimeter. If
you nd obvious signs of damage on the body of the device, do not perform any
measurements! Check that the surface of the multimeter does not have scratches
and that the side joints are not coming apart.
• Also check the insulation on the measuring probes. Damaged insulation may result
in injury by electric current. Do not use damaged measuring probes!
• Do not measure voltages above 600 V! When making measurements, connect the
black conductor rst and the red conductor second. When disconnecting the testing
conductors, disconnect the red one rst.
• If you nd that the meter makes abnormal measurements, stop using it. The fuse may
be damaged. If you are unsure of the cause of the defect, contact a service centre.
• Do not measure voltages higher than listed on the front panel of the multimeter.
Risk of injury by electric current or damage to the multimeter!
• Check that the multimeter works properly before use. Test a circuit with known
electrical quantities.
• Before you connect the multimeter to a circuit you intend to measure, turn o the
power to the circuit.
• Do not use or store the multimeter in environments with high temperature, dustiness
or humidity. It is also not recommended to use the device in environments with
potential strong magnetic elds or risk of explosion or re.
• When replacing parts of the multimeter (e.g. batteries), use spare parts of the same
type and specications. Change parts only when the multimeter is disconnected
and turned o. Disconnect the testing conductors from the tested circuit before
opening the rear casing of the device.
• Do not alter or otherwise interfere with the internal circuitry of the multimeter!
• Be extra careful when measuring voltages higher than 30 V AC rms, 42 V peak or 60
V DC. Risk of injury by electric current!
• When using measuring tips, make sure you are holding them behind the nger
barriers.
• Do not perform measurements if the multimeter's casing is removed or loose.
• Once the at battery icon " " appears on the screen, replace the battery. Otherwise,
subsequent measurements may be inaccurate. Incorrect measurements may then
result in injuries by electric current!
Maintenance Instructions
Warning
Do not attempt to repair or modify the multimeter in any way if you are not qualied to
do so or do not have access to the necessary calibration equipment. Ensure that water
does not enter the interior of the multimeter – you could prevent injury by electric current!
• Disconnect the measuring tips from the tested circuit before opening the casing
of the multimeter.
• Regularly clean the body of the multimeter with a moist cloth and a mild detergent.
Perform cleaning only when the multimeter is disconnected and turned o.
• Do not use solvents or abrasive agents for cleaning!
• If you are not using the multimeter for an extended period of time, turn it o and
remove the batteries.
• Do not store the multimeter in places with high humidity and temperature or in
environments with strong magnetic elds!
Produkt Specifikationer
Mærke: | Emos |
Kategori: | Multimeter |
Model: | MD-510 |
Har du brug for hjælp?
Hvis du har brug for hjælp til Emos MD-510 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Multimeter Emos Manualer
5 September 2024
10 August 2024
7 August 2024
6 August 2024
2 August 2024
1 August 2024
1 August 2024
12 Juli 2024
17 Februar 2024
30 December 2023
Multimeter Manualer
- Amiko
- Meec Tools
- Aldi
- Draper
- Brymen
- Hager
- Maxwell
- Vimar
- Rohde & Schwarz
- Biltema
- Milwaukee
- Högert
- Klein Tools
- Extech
- TFA
Nyeste Multimeter Manualer
8 Juni 2025
7 Juni 2025
7 Juni 2025
6 Juni 2025
6 Juni 2025
6 Juni 2025
6 Juni 2025
6 Juni 2025
6 Juni 2025
3 Juni 2025