Emos M0400 Manual


Læs gratis den danske manual til Emos M0400 (21 sider) i kategorien Multimeter. Denne vejledning er vurderet som hjælpsom af 25 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 13 anmeldelser. Har du et spørgsmål om Emos M0400, eller vil du spørge andre brugere om produktet?

Side 1/21
2202013000_31-M0400_00_01 148 × 210 mm
www.emos.eu
M0400 | MD-410C
GB Digital Clamp Multimeter
CZ Digitální klešťový multimetr
SK Digitálny kliešťový multimeter
PL Multimetr cyfrowy cęgowy
HU Digitális lakatfogó multimeter
SI Digitalni kleščni multimeter
RS|HR|BA|ME Digitalni kliješta multimetar
DE Digitales Zangenmultimeter
UA Цифровий клещі мультиметр
RO Multimetri digital cleşte
LT Skaitmeninis skavas multimetras
LV Digitālais spaiļu multimetrs
EE Digitaalne klambriga multimeter
BG Цифров мултицет тип клещи
3
4 – COM terminal
Connecting terminal for the black (negative) testing conductor.
5 – terminal
Connecting terminal for the red (positive) testing conductor.
6 – HOLD button (hold the value on the screen)
Used to enter or exit hold value mode.
7 – SELECT button
1. Used to switch between diode testing and continuity testing, if the
turn switch in the position.
2. Used to switch between measuring direct current and alternating
current, when the turn switch is in the position.
8 – button
When in direct current measurement mode, the button can be used
to reset the screen before beginning measurement.
During other measurement modes, the button can be used to enter
or exit relative mode.
9 – Grip barrier
Designed to protect the ngers from contact with the tested conduc-
tor. Do not hold the device in places beyond this barrier.
10 – Jaws
Used to grip the conductor when measuring current.
Info for built-in buzzer:
Pressing any button is accompanied by a beep, if the button’s function
is currently active.
A minute before the device switches o automatically, the device will
beep several times. Shortly before switch-o, you will hear a long beep,
then the device turns o.
Measurement Accuracy
Accuracy is specied for the duration of one year after calibration and
only at temperature of 23°C ±5°C with relative humidity of up to 75 %.
Unless expressly specied otherwise, accuracy is specied in range
between 8 % to 100 %.
Accuracy is specied as follows:
± ([% of reading] + [number of least signicant digits])
DC Voltage
Range Resolution Accuracy
400 mV 0.1 mV ± (0.8 % + 5)
4 V 1 mV
± (1 % + 5)
40 V 10 mV
400 V 100 mV
600 V 1 V
Input impedance: 400 mV range: >100 MΩ
other ranges: 10 MΩ
Max. allowable input voltage: 600 V DC
AC Voltage
Range Resolution Accuracy
4 V 1 mV ± (1.2 % + 5)
40 V 10 mV
± (1.5 % + 5)400 V 100 mV
600 V 1 V
Input impedance: 10 MΩ
Frequency range: 40 Hz – 400 Hz
Max. allowable input voltage: 600 V ef.
Response: average, calibrated to the eective value of sine wave
Direct Current (DC)
Range Resolution Accuracy
400 A 0.1 A ± (2.5 % + 5)
Max. allowable input current: 400 A
Temperature coecient
0.1 × (specied accuracy) / °C (<18°C or >28°C)
Alternating Current (AC)
Range Resolution Accuracy
400 A 0.1 A ± (2.5 % + 5)
Frequency range: 50–60 Hz
Max. allowable input current: 400 A
Response: average, calibrated to the eective value of sine wave
Temperature coecient
0.1 × (specied accuracy) / °C (<18°C or >28°C)
Resistance
Range Resolution Accuracy
400 Ω 100 mΩ ± (1.2 % + 7)
4 kΩ 1 Ω
± (1.0 % + 5)40 kΩ 10 Ω
400 kΩ 100 Ω
4 MΩ 1 kΩ ± (1.2 % + 5)
40 MΩ 10 kΩ ± (1.5 % + 7)
Overload protection: 250 V peak
Circuit Continuity Test
Range Description Resolution Overload
protection
0.1 Ω
If resistance is lower
than approx. 30 Ω,
you will hear a buzzer.
250 V peak
Note:
If resistance is between 30 Ω and 150 Ω, the buzzer may or may not sound.
If resistance is higher than 150 Ω, the buzzer will not sound.
Diode Test
Range Description Resolution Overload
protection
1 mV
Displays approximate
voltage loss in
the current ow
direction; Voltage in
open circuit: approx.
2 V; Testing current:
approx 0.6 mA
250 V peak
Temperature Measurement
Range Resolution Accuracy
-20°C ~ 0°C
1°C
± (4 % + 5)
0°C ~ 400°C ± (1 % + 5)
400°C ~ 1 000°C ± (2 % + 5)
The stated accuracy is valid at ambient temperature stability of ±1°C.
If ambient temperature stability is ±5°C, the stated accuracy is valid
after 1 hour has passed.
Hold Measured Value Mode
Pressing the HOLD button holds the measured value on the screen.
A symbol will be displayed on the screen as an indicator.
If you want to cancel the mode, press the HOLD button again.
The symbol will disappear.
Using Relative Mode
Selecting relative mode makes meter save the current measured value
as a reference for subsequent measurements and resets the value on
the screen.
1. Press the button. The multimeter will enter relative mode
and saves the current measured value as a reference for subsequent
measurements. A symbol will appear on the screen as an indicator.
The screen will display zero.
2. When you make a new measurement, the screen will display the dif-
ference between the reference value and the newly measured value.
3. If you want to cancel relative mode, press the button again.
The icon will disappear.


Produkt Specifikationer

Mærke: Emos
Kategori: Multimeter
Model: M0400

Har du brug for hjælp?

Hvis du har brug for hjælp til Emos M0400 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Multimeter Emos Manualer

Emos

Emos M3216 Manual

5 September 2024
Emos

Emos M0400 Manual

10 August 2024
Emos

Emos M0320 Manual

7 August 2024
Emos

Emos M2092 Manual

6 August 2024
Emos

Emos MD-410 Manual

2 August 2024
Emos

Emos M0430 Manual

1 August 2024
Emos

Emos MD-220 Manual

1 August 2024
Emos

Emos M92A Manual

12 Juli 2024
Emos

Emos M0391 Manual

17 Februar 2024
Emos

Emos M0230 Manual

30 December 2023

Multimeter Manualer

Nyeste Multimeter Manualer

Draper

Draper 52320 Manual

8 Juni 2025
VOREL

VOREL 81780 Manual

7 Juni 2025
Brymen

Brymen BM878 Manual

7 Juni 2025
Brymen

Brymen BM789 Manual

6 Juni 2025
Draper

Draper 16232 Manual

6 Juni 2025
Draper

Draper 41822 Manual

6 Juni 2025
Draper

Draper 41820 Manual

6 Juni 2025
Brymen

Brymen BM805s Manual

6 Juni 2025
Brymen

Brymen BM785 Manual

6 Juni 2025
Brymen

Brymen BM239R Manual

3 Juni 2025