Extech EX320 Manual


Læs gratis den danske manual til Extech EX320 (14 sider) i kategorien Multimeter. Denne vejledning er vurderet som hjælpsom af 26 personer og har en gennemsnitlig bedømmelse på 5.0 stjerner ud af 13.5 anmeldelser. Har du et spørgsmål om Extech EX320, eller vil du spørge andre brugere om produktet?

Side 1/14
User's Guide
Mini Multimeter
with Non-Contact Voltage Detector (NCV)
Model EX320
EX320-en-GB_V5.5 4/15 2
Introduction
Congratulations on your purchase of the Extech EX320 Meter. The EX320 offers AC/DC Voltage,
AC/DC Current, Resistance, Diode, Continuity, non-contact Voltage Detection. Proper use and care of
this meter will provide many years of reliable service.
Safety
This symbol adjacent to another symbol, terminal or operating device indicates
that the operator must refer to an explanation in the Operating Instructions to
avoid personal injury or damage to the meter.
This WARNING symbol indicates a potentially hazardous situation, which if not
avoided, could result in death or serious injury.
This CAUTION symbol indicates a potentially hazardous situation, which if not
avoided, may result damage to the product.
This symbol advises the user that the terminal(s) so marked must not be
connected to a circuit point at which the voltage with respect to earth ground
exceeds 600V.
This symbol adjacent to one or more terminals identifies them as being associated
with ranges that may, in normal use, be subjected to particularly hazardous
voltages. For maximum safety, the meter and its test leads should not be handled
when these terminals are energized.
This symbol indicates that a device is protected throughout by double insulation or
reinforced insulation.
SAFETY INSTRUCTIONS
This meter has been designed for safe use, but must be operated with caution. The rules listed
below must be carefully followed for safe operation.
1. NEVER apply voltage or current to the meter that exceeds the specified maximum:
Input Protection Limits
Function Maximum Input
V DC or V AC 600V AC and DC
mA AC/DC 500mA DC/AC
A AC/DC 10A DC/AC (for 30 seconds max. every 15
minutes
Resistance, Diode Test, Continuity 250V DC/AC
Temperature 250V DC/AC
2. USE EXTREME CAUTION when working with high voltages.
3. DO NOT measure voltage if the voltage on the "COM" input jack exceeds 600V above earth
ground.
4. NEVER connect the meter leads across a voltage sour
ce while the function switch is in the
current, resistance, or diode mode. Doing so can damage the meter.
5. ALWAYS discharge filter capacitors in power s
upplies and disconnect the power when making
resistance or diode tests.
6. ALWAYS turn off power and disconnect test leads before opening the covers to replace the fuse
or battery.
7. NEVER operate the meter unless the back cover and the battery and fuse covers are in place
and fastened securely.
8. If the equipment is used in a manner not specified by the manufacturer, the protection provided
by the equipment may be impaired.
WARNING
CAUTION
MAX
600V


Produkt Specifikationer

Mærke: Extech
Kategori: Multimeter
Model: EX320

Har du brug for hjælp?

Hvis du har brug for hjælp til Extech EX320 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Multimeter Extech Manualer

Extech

Extech 380942 Manual

22 December 2024
Extech

Extech MA440 Manual

28 August 2024
Extech

Extech EX355 Manual

27 August 2024
Extech

Extech EX623 Manual

27 August 2024
Extech

Extech MA443 Manual

27 August 2024
Extech

Extech MG302 Manual

23 August 2024
Extech

Extech Ex 830 Manual

17 August 2024
Extech

Extech Ex 810 Manual

14 August 2024
Extech

Extech EX 710 Manual

13 August 2024
Extech

Extech MA1500 Manual

12 August 2024

Multimeter Manualer

Nyeste Multimeter Manualer

Draper

Draper 52320 Manual

8 Juni 2025
VOREL

VOREL 81780 Manual

7 Juni 2025
Brymen

Brymen BM878 Manual

7 Juni 2025
Brymen

Brymen BM789 Manual

6 Juni 2025
Draper

Draper 16232 Manual

6 Juni 2025
Draper

Draper 41822 Manual

6 Juni 2025
Draper

Draper 41820 Manual

6 Juni 2025
Brymen

Brymen BM805s Manual

6 Juni 2025
Brymen

Brymen BM785 Manual

6 Juni 2025
Brymen

Brymen BM239R Manual

3 Juni 2025