Læs gratis den danske manual til Fischer Amps ALC 161 II (4 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 12 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 6.5 anmeldelser. Har du et spørgsmål om Fischer Amps ALC 161 II, eller vil du spørge andre brugere om produktet?

Side 1/4
1
FISCHER AMPS
INNOVATIVE TECHNOLOGY FOR STAGE AND SOUND
MANUAL
Professional Rackmount Charger ALC 161 II
Dear customer,
You have decided to buy a
FISCHER AMPS
product. Thank you.
This product as well as the accompanying rechargeable batteries been developed according to the latest has
state- - -of the art of technology and will be steadily developed further as required. The Charger complies with the
European Safety Standards and VDE (Association of German Electrical Engineers) regulations.
Please read this manual carefully prior to the first use, you will get important information for use and safety
of the unit. These safety and operating instructions should be retained for future reference.
Should you have further questions, please do not hesitate to contact FISCHER AMPS.
BEFORE FIRST OPERATION:
When choosing your rechargeable batteries, ensure that they are suitable for fast charging. Particularly
older or very cheap batteries are often not admitted for this type of charging.
New rechargeable batteries
- If batteries are supplied in the unit are already charged. You should , the batteries re- charge all batteries
first before using them, since they discharge after a long storage time.
- The maximum capacity of the rechargeable battery is only achieved after several charging/discharging
cycles.
What you should note in general when working with NiCd and NiMH rechargeable batteries:
- Do not dispose of batteries in domestic waste, but take them to a battery collecting point.
- - Use nickel/metal hydride (NiMH) rechargeable batteries instead of nickel/cadmium (NiCd) batteries, since NiCd
cells contain environment-polluting and unhealthy heavy metals. NiMH batteries have a higher capacity and thus
longer operating times.
- Do not charge batteries in extreme cold or hot (> 40 °C) conditions.
- Always store a rechargeable battery in charged condition when the rechargeable battery is not used for a longer
period of time.
- - After a longer time of non use, recharge battery before use.
(NiMH batteries have a self- discharge rate of approx. 10 % per month when not used.)
2
Functional description of the FISCHER AMPS Chargers:
The 161 harger has or batteries each The FISCHER AMPS ALC C 4 charging chambers or 4 f AA AAA . new version
of the ALC 161 has 16 separate channels. Each of the charging chambers is controlled separately by 4 micro
controllers. After inserting the charging box with the batteries into the charging chamber, a voltage measuring
process detects whether the battery is extremely deep In this case, the battery is charged in refresh -discharged.
mode with a small amount of current until a voltage has been reached which allows fast charging. In fast charging
mode, the status LED of the corresponding charging chamber flashes red every seconds2 . A defective battery
which cannot be charged any more is therefore detected, because it does not reach the voltage required for fast
charging. In case of battery fault, the status LED of the charging chamber flashes every second. When a regularly
discharged battery is inserted, fast charging starts immediately.
In fast charging mode, the status LED of the charging flashes red every 2 seconds. After a qualifying period for
voltage stabilisation at the battery, the charging current is switched off for a short time and the voltage of the battery
is measured. After approx.. minutes of charging the controller detects if a AA15 - bor a AAA attery is inserted and
controls the charging current to 800mA for AA batteries and 400mA for AAA batteries .
When the charging processor detects that the battery is fully charged, the fast charging current is switched off and
the battery is kept full by means of trickle charging until it is removed, while the status LED lights red with short
OFF- cimpulses. The battery can remain in the harger without danger of overloading. When the batteries are not
needed for a longer time, switch o f the charger and reload the batteries to maximum capacity before use. This f
saves electric power and our environment.protects
A fully charged battery is detected as "charged" after approx. 10 to 15 min. when charged again (i. e.
switching on the Charger) and changeover to trickle charging mode is made.
Commissioning:
Power Cable:
Plug in the pole power cable into the mounting jack 3- at the rear connector panel of the Charger. unit iThe ncludes
a switching power supply with an input voltage of 100V to 240VAC with 47Hz to 63 ALC 161Hz. The ha pole s a 3-
power supply line and therefore has to be connected to a 3 pole plug with earthing. - Voltage adjustment of the
units is made automatically depending on the mains voltage. Inside the units are no exchangeable fuses.
The ALC161 wire fuse 1A -is fused with a fine in the mains input connector. The fuse holder at the mains -
input connector contain There are no further fuses inside the unit which could be replaced.s a spare fuse.
Switching on the Charger:
The mains switch with a blue LED is at the front of the Charger on the left. After switching to position “ON”, the blue
power LED lights. If the batteries have already been inserted the charging process start immediately. When , es
charging, the LEDs of the chambers with batteries light red every 2 seconds.