Your Room Thermostat takes the average room temperature of last 40 seconds as
basis. If the room temperature goes above the hysteresis positive temperature
value you set, your Room Thermostat will start the cooling unit. If it goes below the
hysteresis negative temperature value, your Room Thermostat will stop the cooling
unit. Thus, it ensures that the room temperature remains within a certain range.
Your Room Thermostat sends the last status signal to the Receiver every 3 minutes.
Thus, your Room Thermostat and Receiver work synchronously. If the signal cannot
reach to the Receiver from the Room Thermostat for 22 minutes, it perceives that
the connection is broken and stops the heating/cooling operation for safety
reasons. Likewise, in cases where the electricity comes back after a power failure,
the Receiver do not operate the heating/cooling unit until 'operate' signal reaches
from the Room Thermostat.
However, in this case, if the Room Thermostat continues to operate normally, it will
continue to work properly without any need for intervention since it sends a status
signal to the Receiver every 3 minutes.
FREQUENTLY ASKED QUESTIONS
Is my Room Thermostat compatible with my heating/cooling unit?
If your heating / cooling unit has on-off connections, your Room Thermostat is
compatible. You can find information about your heating / cooling unit from your
heating / cooling unit operating manual or from your heating / cooling unit service.
How will I connect my heating/cooling unit with my Receiver?
We recommend that the connection between the Receiver and heating/cooling unit
should be made by professionally qualified persons.
2x0.75 mm cable is sufficient for the Receiver – heating/cooling unit connection.
Connect one end of the cable pair to the room thermostat connection terminals
stated in the user manual of your heating/cooling unit.
Connect the other end of the cable pair to COM and NO inputs of the terminal inside
the Receiver as shown in the "RECEIVER WIRING DIAGRAM" section.
The direction of the cable ends does not matter.
DECLARATION OF CONFORMITY
ISIPARK İÇ VE DIŞ TİC. İNŞ. ISITMA SİSTEMLERİ OTO. SAN.A.Ş.which Head Office
and production site is located on Fatih Mah. 1188 Sk.No:13/A Sarnıç - Gaziemir -
İZMİR – TÜRKİYE confirms and declares that the product marked with CE and its
specifications below is covered by the provisions of the mentioned directive.
The product manufactured by ISIPARK and mentioned above is connected
wirelessly at 2.4 Ghz internet and periodically shares the temperature and status
information with the server on the internet.
Radio and Telecommunications Terminal Equipment Regulation
2014/53/EU (ETSI EN 301 489-1 V2.2.3 (2019-11),
ETSI EN 301 489-17 V3.2.4 (2020-09), EN 300 220-1 V3.1.1,
EN 300 220-2 V3.2.1 (2018-06), EN 62479: 2010, EN 62368-1:2014+A11:2017)
Electromagnetic Compatibility Regulation 2014/30/EU
(ETSI EN 301 489-1 V2.2.3, ETSI EN 301 489-3 V2.1.1)
Low Voltage Directive 2014/35/EU (EN 60730-2-9)
Supplementary Information: Mentioned product can be used with combi boilers
with on / off output and compatibility with the directive only covers the product.
ISIPARK is not responsible for the compliance of the entire system with the
directive. This declaration does not apply when changes are made to the product
without obtaining our consent.
1- The warranty period starts from the invoice date and warranted against
manufacturing defects for 2 years.
2-Devices and apparatus are delivered to the customer in working condition in our
company. On-site commissioning is subject to a service fee.
3-The repair of the devices and apparatus covered by the warranty is carried out in
our company factory and should send by contracted transportation company. In on-
site services, the transportation and accommodation expenses of the service
personnel belong to the customer. The shift fee during transportation is added to
the service fee and collected in advance.
4-The maintenance of devices and apparatus is done in our company. For the
maintenance of the devices and apparatus, the round travel fares belongs to the
5-In case of malfunctioning of the devices and apparatus whose warranty period
continues, it is tested in our company whether the malfunction is caused by a
customer or manufacturer fault, and it is reported with a report issued by our
6-In case of detection of manufacturer-induced errors of devices and apparatus
whose warranty period continues, the customer can request a replacement or
repair of the devices and apparatus at full expense by the manufacturer, unless it's
higher than the product's price
7-In the event that the faults of the devices and apparatus whose warranty period
continues are determined as caused by the customer, all expenses would be belong
8-Customers should be aware of damages (if there is any) of product and warn
manufacturer since the day warranty duration starts.If customer do not warn
manufacturer with knowledge of damage, customer lose the rights of article 6.
9-Malfunctions resulting from the use of devices and apparatus contrary to the
matters stated in the User Manual are not covered by the warranty.
10-Devices and their apparatus are out of warranty if they are beaten, broken or
scratched by the customer.
11-Damages resulting from the use of devices and apparatus belonging to other
brands and models without the approval of the manufacturer are not covered by the
12-Battery leakage and errors due to rust, oxidation and liquid contact by working in
acidic / humid environments are not covered by the warranty.
13-When the product is not used for a long period (more than 15 days), remove the
batteries. Otherwise, malfunctions that will occur are out of warranty.
14-Damages that may occur during the transportation of devices and apparatus are
not covered by the warranty. Customers can take a transportation insurance.
15-Damages caused by mains voltage / faulty electrical installation are not covered
16-Devices and apparatuses are out of warranty for malfunctions caused by force
majeure such as fire, flood, earthquake etc.
17-All of the devices and apparatuses, including all their parts, are under the
18-In case of malfunction of the devices and apparatuses within the warranty
period, the time spent during repairment period is added to the warranty period. The
repair period of the product cannot exceed 20 working days. This period starts from
the date of notification to the service station of the malfunction related to the
product or, in the absence of a service station, to the seller, dealer, agency,
representative, importer or manufacturer of the product. Consumer can report the
problem by; phone, fax, e-mail, registered and reply paid letter or a similar way.
However, in case of a conflict, responsibility of prove is belong to the customer. If
the malfunction of the product is not repaired within 20 working days, the
manufacturer-producer or importer; has to allocate another product with similar
features to the use of the consumer until the repair of the product is completed,
19-Although the consumer uses his/her repair rights,
-If the product breaks down for 4 times in a year or 6 times in warranty duration and
these problems effects main purpose of the product.
(starting from delivery time during warranty.)
- Exceeding the maximum time required for repair,
- In the event that the service station is not available, if it is determined that the
repair of the defect is not possible with the report prepared (in order) by one of the
seller, dealer, agency, representative, importer or manufacturer, a refund or a price
discount at the rate of defect can be requested.
20-The customer can make complaints and appeals to consumer courts or
consumer arbitration committees.
21-The warranty document must be kept by the customer during the warranty
period. If the document is lost, a second document will not be issued. In case of
loss, repair and replacement of devices and apparatus will be made for a fee.
OPEN WINDOW DETECTION FEATURE
If a window is left open, cold air will enter and the temperature in the room will drop
rapidly. In cooling systems, hot air will enter and the temperature in the room will
rise rapidly. The Room Thermostat, which detects this situation, tries to keep the
room temperature at the desired level by operating the heating or cooling system
more. The open window detection feature allows the Room Thermostat to operate
the heating/cooling system more efficiently in case the temperature in the room
This feature is used to save energy and to ensure more efficient operation of heating
and ccoling systems. Thanks to the open window detection feature, unnecessary
energy expenditure is prevented and allows the user to save energy costs.
When the Room Thermostat is in heating mode and the Open window detection
feature is active, if it detects a sudden drop in room temperature up to the degree
adjusted in the Set menu (factory setting 5 C) within 15 minutes, it switches to
alarm status, the open window icon flashes on the display of the Room Thermostat
and switches off the heating/cooling unit. The heating/cooling unit remains off for
the time adjusted in the Run Menu. If the Room Thermostat detects that the window
is closed or if a manual intervention is made on the Room Thermostat, the detection
is deactivated and heating/coolin unit continues to operate from where it left off. If
a sudden drop in ambient temperature is detected again, the Room Thermostat
If the Room Thermostat is operated in cooling mode, the sudden temperature rise in
This feature is active in factory setting.
It can be deactivated from the Room Thermostat settings.
To deactivate the open window detection feature:
Press the “ON/OFF” button for 3 seconds while your device is turned off.
Press the “ON/OFF” button until the “ ” menu appears.
While in the “ ” menu, turn the button to left. The “ ” option will appear.
To save the settings and exit, press the “ON/OFF” button until the device turns off.
The settings you have made are saved. Your device will work with the setting you
have made when you open it.
OPEN WINDOW DETECTION OPERATION SETTINGS
Set Menu allows you to set the value of the sudden temperature change (celsius)
required for your Room Thermostat to activate the open window detection feature.
The factory setting of the required sudden temperature change value is 5 C. This
value can be adjusted between 2 C and 10 C.
To change the open window operating temperature:
Press and hold the button for 3 seconds while the device is switched off.
Press the button until the “ ” menu appears.
In the “ ” menu that appears, adjust the operating temperature by turning the
button to the right or left.
To save the settings and exit, press the button until the device switches off.
The settings you have made have been saved. Once you turn on your device, it will
operate with the changed settings.
Run Menu allows you to set the off time of the heating/cooling unit while the open
window detection feature of your Room Thermostat is active. The factory setting
for off time is 10 minutes.
Press and hold the button for 3 seconds while your device is switched off.
Press the button until the “ ” menu appears.
Set the operating time of the open window detection feature by turning the button
to the right or left in the “ ” menu.
To save the settings and exit, press the button until the device switches off.
The settings you have made have been saven. Once you turn on your device, it will
operate with the changed settings.
You can reset your Room Thermostat to its default factory settings. This operation
resets the calibration setting, heating/cooling modes and hysteresis settings to
factory setting. To reset your Room Thermostat to factory setting:
While your device is turned off, press and hold the button for 3 seconds.
Press the button until the “ ” menu appears.
While in the “ “ menu, turn the button to right or left in order to select “ “
option and press the button.
Your device will be turned off and reset to factory settings.
ROOM THERMOSTAT WORKING LOGIC
Your room thermostat takes the average room temperature of last 40 seconds as
basis. If the room temperature goes above the hysteresis positive temperature
value you set, your Room Thermostat will stop the heating unit. If it goes below the
hysteresis negative temperature value, your Room Thermostat will start the heating
unit. Thus, it ensures that the room temperature remains within a certain range.
ISIPARK reserves the rights of changing product specifications and user manuals.
* For all changes, you may visit generallife.com.tr
Type: Smart Room Thermostat
Model: HT25 SMART/HT25S SMART
Title: ISIPARK İÇ DIŞ TİC. A.Ş.
Adress: Fatih Mah. 1188 Sk. No:13/A Sarnıç Gaziemir İzmir-TÜRKİYE
E-mail: generallife@generallife.com.tr
Type: Smart Room Thermostat
Model: HT25 SMART/HT25S SMART
Max. Time to Repair: 20 Days