Title: ISIPARK İÇ DIŞ TİC. A.Ş.
Address: Fatih Mah. 1188 Sk. No:13/A Sarnıç
E-Mail: generallife@generallife.com.tr
Type: Smart Room Thermostat
Model: HT301 SMART/HT301S SMART
Guarantee Period: 2 Years
Max. Time to Repair: 20 Days
Banderole and Serial Number:
Type: Smart Room Thermostat
Model: HT301 SMART/HT301S SMART
Isıpark reserves the rights of changing product specifications and user manuals.
*For all changes,you may visit generallife.com.tr
OPEN WINDOW DETECTION FEATURE
Your room thermostat measures sudden temperature changes in your house with
its open window detection feature and prevents unnecessary energy consumption
by turning off the heating/cooling unit.
The room thermostat is switched to heating mode while the detection is active. If a
decrease in room temperature of more than 5 degrees is detected within 15
minutes, the room thermostat switches to the alarm state and turns off the heating
The heating unit remains switched off for 10 minutes unless manual intervention is
performed on the room thermostat. A warning appears on the mobile application
that an open window has been detected. The heating unit is activated at the end of
10 minutes. If the room thermostat detects that the window is closed, the heating
unit continues to work. If the temperature continues to drop, the heating unit is
If the room Thermostat is operated in cooling mode, a sudden temperature rise is
This feature can be enabled/disabled from the room thermostat settings:
Press the “ON/OFF” button for 3 seconds while your device is turned off.
Press the “ON/OFF” button until the “ ” menu appears.
Press the “Up” or “Down” button while in the “ ” menu to choose the “ ” or
“ ” option and press the “ON/OFF” button.
To save the settings and exit, press the “ON/OFF” button until the device turns off.
The settings you have made are saved. Your device will work with the setting you
have made when you open it.
You can reset your Room Thermostat to its default factory settings. This operation
resets the mode temperature values, calibration setting, heating/cooling modes,
and hysteresis settings to the factory setting. To reset your room thermostat to
While your device is turned off, press the “ ”ON/OFF button for 3 seconds.
Press the “ON/OFF” button until the “ ” menu appears.
While in the “ ” menu, select the “ ” option by using the “+” or “-” buttons
and press the “ON/OFF” button.
Your device will be turned off and reset to factory settings.
While your Room Thermostat is on, keep pressing Weekly Program button the “ ”
At the first screen that appears, hour part will be blinking. You may set the time
with the “ ”Up and “ ”Down buttons.
After setting the time, the “Heating & Cooling Option” button needs to be pressed
once. For minute setting, minute part will be blinking. You may set the minute with
the “ ”Up and “ ”Down buttons.
After setting the minute, the “Settings” button needs to be pressed once to set the
Monday has set as the first day of the week and indicated with number “1".
Numbers indicate the following days respectively 2-Tuesday, 3-Wednesday, 4-
Thursday, 5-Friday, 6-Saturday and 7-Sunday
When setting is done, you may exit by pressing the “Weekly Program” button for 3
Your Room Thermostat has different modes. of them (Comfort Economy4 2 and
Mode) are preset modes. Other modes are manual mode and weekly program
In preset modes, temperature values are based on user's choices which have been
set in the beginning. Manual mode allows the Room Thermostat to operate within
the temperature which is required and set directly by user. Weekly Program mode
continues to work according to the weekly schedule determined by the user.
In order to change the temperature values of preset modes:
Press and hold the “Mode” button for 3 seconds while your Room Thermostat is
Comfort Mode temperature value will appear. You may adjust the temperature
value of Comfort Mode by pressing the “Up” and “Down” button .s
When setting is done, you may adjust the temperature value of Economy Mode
with the “Up” and “Down” button by pressing the “Mode” button again.s
You may exit the setting screen by pressing the “Mode” button 3 seconds.
In order to change the manual mode temperature, press the “Up” or “Down” button
while in the main screen. The Room Thermostat will switch to Manual Mode once
pressed the “Up” or “Down” button.
You may press the “Mode” button to switch to the other modes.
You may set the operating schedule of your Room Thermostat with weekly program
mode. 7 different temperature values can be set for each day in weekly
programming. These values can be set in temperature adjustment screens '' P0-P6''.
In order to set the weekly schedule, press and hold the “Weekly Program“ button
for 3 seconds while your Room Thermostat is on. The “Hour, Minute and Day”
setting will appear. Press the Settings“ ” button until the “Weekly Program” menu
Days of the week will be blinking on the screen. You can initiate the weekly
program setting if you wish to set the same schedule for every day of the week.
Press the “Up“ button once if you wish to set the same schedule for the weekdays.
First five days of week will be blinking on the screen.
Press the “Up“ button once more if you wish to set the same schedule only for the
weekend. Last two days of the week will be blinking on the screen.
Press the “Up“ button one more time if you wish to set the same schedule for
every day of the week. 1st day of the week will be blinking on the screen. You can
switch between the days by pressing the “Up“ button. Press the “Down“ button in
order to switch to the previous day.
Press the “Weekly Program“ button once to set a schedule.
“P0” will be blinking on the screen. Set the temperature value of “P0” by pressing
the “Weekly Program“ button once more. The hour setting of “P0” cannot be
changed since it's factory setting.
Press the “Weekly Program” button again. Day indicator will be blinking. If you will
not change the day, press the “Weekly Program” button again and switch to the
“P1” setting by pressing the “Up” button.
First, hour setting will appear on the screen. Once you complete the hour setting,
adjust the minute setting by pressing the “Weekly Program” button. After the
minute setting, press the “Weekly Program” button to set the temperature value.
Follow the same steps for other schedule settings.
Once all changes made, press and hold the “Weekly Program” button for 3
Note: In order to check the weekly schedule which has been set without making any
changes, press the “Weekly Program” button once while your Room Thermostat is
on. Press the “Up” and “Down” buttons to see the days, press the “Mode” button to
see the settings between “P0-P6”.
ROOM THERMOSTAT WORKING LOGIC
Your room thermostat takes the average room temperature of the last 40 seconds
as the basis. If the room temperature goes above the hysteresis positive
temperature value you set, your room thermostat will stop the heating unit. If it goes
below the hysteresis negative temperature value, your room thermostat will start
the heating unit. Thus, it ensures that the room temperature remains within a
Your Room Thermostat takes the average room temperature of last 40 seconds as
basis. If the room temperature goes above the hysteresis positive temperature
value you set, your Room Thermostat will start the cooling unit. If it goes below the
hysteresis negative temperature value, your Room Thermostat will stop the cooling
unit. Thus, it ensures that the room temperature remains within a certain range.
Your Room Thermostat sends the last status signal to the Receiver every 3 minutes.
Thus, your Room Thermostat and Receiver work synchronously. If the signal cannot
reach to the Receiver from the Room Thermostat for 22 minutes, it perceives that
the connection is broken and stops the heating/cooling operation for safety
reasons. Likewise, in cases where the electricity comes back after a power failure,
the Receiver does not operate the heating/cooling unit until 'operate' signal reaches
from the Room Thermostat. However, in this case, if the Room Thermostat
continues to operate normally, it will continue to work properly without any need for
intervention since it sends a status signal to the Receiver every 3 minutes.
FREQUENTLY ASKED QUESTIONS
Is my Room Thermostat compatible with my heating/cooling unit?
If your heating/cooling unit has On-Off connections, your Room Thermostat is
compatible. You can find information about your heating/cooling unit from your
heating/cooling unit operating manual or from your heating/cooling unit service.
How will I connect my heating/cooling unit with my Receiver?
We recommend that the connection between the Receiver and heating/cooling unit
should be made by professionally qualified persons.
2x0.75 mm cable is sufficient for the Receiver – heating/cooling unit connection.
Connect one end of the cable pair to the room thermostat connection terminals
stated in the user manual of your heating/cooling unit.
Connect the other end of the cable pair to COM and NO inputs of the terminal inside
the Receiver as shown in the "RECEIVER WIRING DIAGRAM" section.
The direction of the cable ends does not matter.
DECL ARATI ON OF C ONFORM ITY
ISIPARK İÇ VE DIŞ TİC. İNŞ. ISITMA SİSTEMLERİ OTO. SAN.A.Ş.which Head Office and
production site is located on Fatih Mah. 1188 Sk.No:13/A Sarnıç - Gaziemir - İZMİR –
TÜRKİYE confirms and declares that the product marked with CE and its specifications below
is covered by the provisions of the mentioned directive.
The product manufactured by ISIPARK and mentioned above is connected wirelessly at 2.4
Ghz internet and periodically shares the temperature and status information with the server
Radio and Telecommunications Terminal Equipment Regulation
2014/53/EU (ETSI EN 301 489-1 V2.2.3 (2019-11),
ETSI EN 301 489-17 V3.2.4 (2020-09), EN 300 220-1 V3.1.1,
EN 300 220-2 V3.2.1 (2018-06), EN 62479: 2010, EN 62368-1:2014+A11:2017)
Electromagnetic Compatibility Regulation 2014/30/EU
(ETSI EN 301 489-1 V2.2.3, ETSI EN 301 489-3 V2.1.1)
Low Voltage Directive 2014/35/EU (EN 60730-2-9)
Supplementary Information: Mentioned product can be used with combi boilers with on / off
output and compatibility with the directive only covers the product. ISIPARK is not
responsible for the compliance of the entire system with the directive. This declaration does
not apply when changes are made to the product without obtaining our consent.
1- The warranty period starts from the invoice date and warranted against manufacturing
2-Devices and apparatus are delivered to the customer in working condition in our company.
On-site commissioning is subject to a service fee.
3-The repair of the devices and apparatus covered by the warranty is carried out in our
company factory and should send by contracted transportation company. In on-site
services, the transportation and accommodation expenses of the service personnel belong
to the customer. The shift fee during transportation is added to the service fee and collected
4-The maintenance of devices and apparatus is done in our company. For the maintenance of
the devices and apparatus, the round travel fares belongs to the customer.
5-In case of malfunctioning of the devices and apparatus whose warranty period continues,
it is tested in our company whether the malfunction is caused by a customer or manufacturer
fault, and it is reported with a report issued by our company.
6-In case of detection of manufacturer-induced errors of devices and apparatus whose
warranty period continues, the customer can request a replacement or repair of the devices
and apparatus at full expense by the manufacturer, unless it's higher than the product's price
7-In the event that the faults of the devices and apparatus whose warranty period continues
are determined as caused by the customer, all expenses would be belong to the customer.
8-Customers should be aware of damages (if there is any) of product and warn manufacturer
since the day warranty duration starts.If customer do not warn manufacturer with
knowledge of damage, customer lose the rights of article 6.
9-Malfunctions resulting from the use of devices and apparatus contrary to the matters
stated in the User Manual are not covered by the warranty.
10-Devices and their apparatus are out of warranty if they are beaten, broken or scratched by
11-Damages resulting from the use of devices and apparatus belonging to other brands and
models without the approval of the manufacturer are not covered by the warranty.
12-Battery leakage and errors due to rust, oxidation and liquid contact by working in acidic /
humid environments are not covered by the warranty.
: HT301 SMART/HT301S SMART
13-When the product is not used for a long period (more than 15 days), remove the batteries.
Otherwise, malfunctions that will occur are out of warranty.
14-Damages that may occur during the transportation of devices and apparatus are not
covered by the warranty. Customers can take a transportation insurance.
15-Damages caused by mains voltage / faulty electrical installation are not covered by the
16-Devices and apparatuses are out of warranty for malfunctions caused by force majeure
such as fire, flood, earthquake etc.
17-All of the devices and apparatuses, including all their parts, are under the warranty of our
18-In case of malfunction of the devices and apparatuses within the warranty period, the
time spent during repairment period is added to the warranty period. The repair period of the
product cannot exceed 20 working days. This period starts from the date of notification to the
service station of the malfunction related to the product or, in the absence of a service
station, to the seller, dealer, agency, representative, importer or manufacturer of the product.
Consumer can report the problem by; phone, fax, e-mail, registered and reply paid letter or a
similar way. However, in case of a conflict, responsibility of prove is belong to the customer. If
the malfunction of the product is not repaired within 20 working days, the manufacturer-
producer or importer; has to allocate another product with similar features to the use of the
consumer until the repair of the product is completed,
19-Although the consumer uses his/her repair rights,
-If the product breaks down for 4 times in a year or 6 times in warranty duration and these
problems effects main purpose of the product.
(starting from delivery time during warranty.)
- Exceeding the maximum time required for repair,
- In the event that the service station is not available, if it is determined that the repair of the
defect is not possible with the report prepared (in order) by one of the seller, dealer, agency,
representative, importer or manufacturer, a refund or a price discount at the rate of defect can
20-The customer can make complaints and appeals to consumer courts or consumer
21-The warranty document must be kept by the customer during the warranty period. If the
document is lost, a second document will not be issued. In case of loss, repair and
replacement of devices and apparatus will be made for a fee.