Gossen Metrawatt Metrahit Outdoor Manual

Gossen Metrawatt Multimeter Metrahit Outdoor

Læs gratis den danske manual til Gossen Metrawatt Metrahit Outdoor (70 sider) i kategorien Multimeter. Denne vejledning er vurderet som hjælpsom af 18 personer og har en gennemsnitlig bedømmelse på 4.9 stjerner ud af 9.5 anmeldelser. Har du et spørgsmål om Gossen Metrawatt Metrahit Outdoor, eller vil du spørge andre brugere om produktet?

Side 1/70
SECULIFEHITAM HITMD
METRAHIT AM BASE, , , AM PRO AM TECH AM XTRA *
METRAHIT OUTDOOR
Advanced Multimeters / Special Multimeters
Operating Instructions
3-349-352-03
17/2.20
* These operating instructions also apply to the previous models METRAHIT BASE/PRO/TECH/X-TRA, now AM BASE/AM PRO/AM TECH/AM XTRA
2 GMC-I Messtechnik GmbH
Standard Equipment Contact Persons
Standard Equipment
1 Multimeter
1 Measurement cable set
2 Batteries
1 DAkkS calibration certificate
1 Abbreviated operating instructions
Detailed operating instructions for download from our website
at www.gossenmetrawatt.com
1) Clamp
function METRAHIT AM XTRA and AM PRO as from firmware version 3.04
2) For 15,400 measured values, sampling rate adjustable from 0.1 second to 9 hours
Function SECULIFE
HIT
AM
/
HIT
MD
METRA HIT
AM XTRA
/
OUTDOOR
METRA HIT
AM TECH
METRAHIT
AM PRO
METRAHIT
AM BASE
M687A/M687B M240A/M240O
M243A M242A M241A
V AC / Hz TRMS
(Ri 9 M)
& Filter
& Filter
& Filter
& Filter
V AC TRMS
(Ri = 1 M)
& Filter
& Filter
& Filter
& Filter
V AC+DC TRMS
(Ri 9 M) 
V DC ( 9 M)
... 1 MHz 5 V AC
— —
Duty cycle as % — —
Hz (V AC) ... 100 kHz ... 100 kHz ... 100 kHz ... 100 kHz ... 100 kHz
Bandwidth V AC
15 Hz ... 20 kHz 15 Hz ... 20 kHz 15 Hz ... 10 kHz 15 Hz ... 10 kHz
15 Hz ... 1 kHz
A AC / Hz TRMS 100 A
1/10/100 mA
1 A / 10 (16)
A
100 A
1/10/100 mA
1 A / 10 (16)
A
10/100 mA
1 A / 10 (16)
A
1 A / 10 (16)
A
A AC+DC TRMS
A DC
Fuse 10 A/1000 V 10 A/1000 V 10 A/1000 V 10 A/1000 V
Transformation
factor
1) 
A AC 1)
/ Hz
TRMS
mV/A
mA/A
mV/A
mA/A
mV/A
mA/A
mV/A
mA/A
mV/A
Ri = 1 M
A AC+DC
1)
TRM
S
mV/A
mA/A
mV/A
mA/A
mV/A
mA/A
mV/A
mA/A
mV/A
Ri = 1 M
1kHz
1kHz
1kHz
1kHz
1kHz
1kHz
1kHz
1kHz
A DC
1) mV/A
mA/A
mV/A
mA/A
mV/A
mA/A
mV/A
mA/A
mV/A
Ri = 1 M
Hz (A AC) ... 30 kHz ... 30 kHz ... 30 kHz ... 30 kHz ... 30 kHz
Resistance    
Continuity   
Diode ... 5,1 V 
Temperature TC (K) 
Temperature RTD
— —
Capacitance — —
MIN/MAX/data hold 
4 MBit memory 2) — —
IR Interface — —
Power pack
adapter socket — —
Protection IP65
OUTDOOR:
IP65
IP52 IP52 IP52
Antimicrobial
properties / —
Measuring
category
600 V CAT III
300 V CAT IV
1000 V CAT III
600 V CAT IV
1000 V CAT III
600 V CAT IV
1000 V CAT III
600 V CAT IV
1000 V CAT III
600 V CAT IV
Rubber holster — —
Measurement cable
set
KS17-2AMB/
KS17-2 KS17-2 KS17-2 KS17-2 KS17-2
DAkkS calibration
certificate

Hygiene Expertise — / — — —
Function SECULIFE
HIT
AM
/
HIT
MD
METRAHIT
AM XTRA
/
OUTDOOR
METRA HIT
AM TECH
METRAHIT
AM PRO
METRAHIT
AM BASE
M687A/M687B M240A/M240O
M243A M242A M241A


Produkt Specifikationer

Mærke: Gossen Metrawatt
Kategori: Multimeter
Model: Metrahit Outdoor

Har du brug for hjælp?

Hvis du har brug for hjælp til Gossen Metrawatt Metrahit Outdoor stil et spørgsmål nedenfor, og andre brugere vil svare dig