Læs gratis den danske manual til Gossen Metrawatt U1500 (22 sider) i kategorien Måleudstyr. Denne vejledning er vurderet som hjælpsom af 16 personer og har en gennemsnitlig bedømmelse på 4.5 stjerner ud af 8.5 anmeldelser. Har du et spørgsmål om Gossen Metrawatt U1500, eller vil du spørge andre brugere om produktet?

Side 1/22
Energy Management
110011110000110101010100 011010
Manual for the Use of
Peak Load Optimizing Systems U1500
Manual for the Use of Peak Load Optimizing Systems
2
Preface
Consumption costs for energy sources such as electrical power, gas and district heating, which are billed as a rule based
upon measured power values, can frequently be reduced significantly with only minimal technical efforts. It is precisely
for this reason that in-house energy management should include an assessment for determining whether or not the use
of modern load optimizing systems is practical and efficient.
Detailed knowledge regarding the power supply contract conditions offered by various utility companies, utilized
process sequences and how they can be influenced, and existing equipment and how it is controlled, is necessary for the
preparation of an optimization concept.
This manual is intended to provide decision makers and system technicians with a tool for discovering potential
savings, and for evaluating the efficiency of an optimizing system.
GMC-I MESSTECHNIK GMBH
Südwestpark 15
90449 Nürnberg; Germany
Phone: +49 911 / 8602-0
www.gossenmetrawatt.com
Table of Contents
1 BASICS ...................................................................................................................................................................... 3
1.1 T S C CARIFFS FOR PECIAL ONTRACTS USTOMERS .................................................................................................. 3
2 OPTIMIZING SYSTEMS ........................................................................................................................................ 6
2.1 R AANGE OF PPLICATIONS .................................................................................................................................... 6
2.2 TECHNOLOGY ...................................................................................................................................................... 6
3 FACILITY ANALYSIS .......................................................................................................................................... 10
3.1 A T S C BNALYZING THE ARIFF CHEDULE AND ONSUMPTION ILLING .................................................................... 11
3.2 A I P L CNALYZING THE MPORT ROFILE AND THE OAD URVE ................................................................................ 11
3.3 E AQUIPMENT NALYSIS ....................................................................................................................................... 13
3.4 D R P SETERMINING EALISTIC OTENTIAL AVINGS ................................................................................................. 14
4 TECHNICAL IMPLEMENTATION ................................................................................................................... 15
4.1 I CNSTALLING THE OMPONENTS .......................................................................................................................... 15
4.2 S P E P UIGNALS ROVIDED BY THE LECTRICAL OWER TILITY ................................................................................ 15
4.3 B C CUS AND ONTROL ABLES .............................................................................................................................. 16
4.4 R E EETROFITTING XISTING QUIPMENT ................................................................................................................ 16
4.5 D M F S T C P OEMAND ANAGEMENT AS A IRST TEP OWARDS OMPREHENSIVE LANT PTIMIZATION ......................... 16
5 CALCULATING AMORTIZATION TIME ........................................................................................................ 16
6 CONCLUSION ........................................................................................................................................................ 16
APPENDIX A TARIFF / CONSUMPTION CHECKLIST .................................................................................. 17
APPENDIX B EQUIPMENT CHECKLIST .......................................................................................................... 18
APPENDIX C ECONOMY CHECKLIST ............................................................................................................. 20


Produkt Specifikationer

Mærke: Gossen Metrawatt
Kategori: Måleudstyr
Model: U1500

Har du brug for hjælp?

Hvis du har brug for hjælp til Gossen Metrawatt U1500 stil et spørgsmål nedenfor, og andre brugere vil svare dig