Læs gratis den danske manual til Hikvision DS-PDP18-HM (5 sider) i kategorien Alarmsystem. Denne vejledning er vurderet som hjælpsom af 24 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 12.5 anmeldelser. Har du et spørgsmål om Hikvision DS-PDP18-HM, eller vil du spørge andre brugere om produktet?

Side 1/5
DS-PDP18-HM
Wired Double PIR Detector
User Manual
EN50131-2-2:2021
Security Grade 2
Environment Class IV
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
UD33808B
User Manual Flow Chart
1 Appearance
2 Installation
Bracket Tamper
67.3 mm
141.6 mm
60.0 mm
Tamper Switch
LED Jumper
PIR Sensitivity Jumper
High and Low Mounting Adjustment Lever
H Model (default): 2.5 to 3 m (typical 2.7 m)
L Model: 0.8 to 1.2 m (typical 1 m)
LED OFF
Pet Immunity
LED ON (default)
Auto (default)
1.1 Unbox.
1.2 Check components.
Select the wiring type and
connect the detector to the
control panel.
2.1 Confirm environment.
2.2 Fix the device (Wall
mounting/Bracket mounting).
Check detection range
in H and L mode.
Check the indicator,
and the device is
powered on.
1 Appearance
3 Connect to
Control Panel
2 Installation
5 Detection Range
4 Power on
Installation Environment
Facing Direct
Strong Light
Source of
air currents
Facing reflective
surfaces
Areas with
moving objects
Surface that absorb heat or
rapid temperature change area
1Wall Mounting
2
13
1. Adjust the knob to the
unlock icon.
2. Press the button.
3. Remove the rear panel.
Wire Slot
4. Method 1 (Recommended):
Thread the cables through the
middle wire hole on the rear panel.
4
5
5. Fix the rear panel to the
corresponding position on the wall
with two screws. Remove the wiring
terminal and finish wiring.
Wire Terminal
6
6. Install the wiring terminal
back and fix the cables into
the wire slot.
7. Adjust the high and low
mounting adjustment lever,
and Install the front panel.
7
8. Adjust the knob to the lock icon.
8
Back of Wire hole
4
4. Method 2: Thread the
cables through the wire
hole on the rear panel.
2 Bracket Mounting
1
4. Install the bracket to the wall.
6. Remove the bracket tamper
cover on the front panel.
7. Connect the tamper cable to the front
panel, and fix the cable into the wire slot.
8. Adjust the high and low mounting
adjustment lever, and install the front panel.
45
6
78
1. Adjust the knob to the
unlock icon.
2. Press the button.
3. Remove the rear panel.
5. Install the wiring terminal back and fix the
cables into the wire slot. Thread the tamper
cable through the wire hole, and fix the rear
panel to the bracket with one screw.
Wire Slot
9
9. Adjust the knob to the lock icon.
2
3
Wire Slot