Infratech 21-5080 Manual


Læs gratis den danske manual til Infratech 21-5080 (8 sider) i kategorien Varmeapparat. Denne vejledning er vurderet som hjælpsom af 13 personer og har en gennemsnitlig bedømmelse på 4.9 stjerner ud af 7 anmeldelser. Har du et spørgsmål om Infratech 21-5080, eller vil du spørge andre brugere om produktet?

Side 1/8
TABLE OF CONTEN
RE MANUAL
Warnings
Installation Instructio
Wiring Instructions 3
Bracket Spacing 4
Mounting Instructions 4-5
Replacement Element Installation 5
Replacement Parts 5-6
Heater Coverage Areas 6
General Notes 6
Maintenance Instructions 6
Trouble Shooting 7
Location Suggestions 7
Warranty 8
SAVE THIS MANUAL FOR FUTURE REFERENCE
2
MIN. 18" (45.7cm)
FROM SIDES AND
ENDS OF HEATER
MIN. 36" (91.4cm)
IN FRONT OF HEATER
MIN. 6" (15.2cm)
CLEARANCE
BEHIND HEATER
READ ALL INSTRUCTIONS BEFORE USING HEATER. Unit may be a source of possible shock. NEVER attempt to
service heater without disconnecting its power source. Source of possible ignition.
WARNING: If not installed, operated and maintained in accordance with the manufacturers instructions,
this product can expose you to chemicals including nickel, which are known to the State of California to
cause cancer. For more information go to www.P65Warnings.ca.gov.
High Temperature, risk of fire, keep electrical cords, drapery, furnishings and other combustibles at least 3' (0.9m)
from the front of heater and away from sides and rear.
WARNINGS
CAUTION
MOUNTING HEIGHT/CLEARANCES
“IMPORTANT INSTRUCTIONS”
“SAVE THESE INSTRUCTIONS”
For Wall-Mounting, do not install heater closer than
18" (45.7cm) from adjacent walls and 6" (15.2cm)
from ceiling and do not install less than 6' (1.8m)
if the heater is labeled as UL Listed and 8' (2.4m)
if the heater is labeled as UL/CUL Listed from floor,
while heater is set at a downward angle of 30 to
60 degrees.
For Ceiling- Mounting, do not install heater closer
than 18" (45.7cm) from adjacent walls and 6"
(15.2cm) from ceiling and do not install less than 6'
(1.8m) if the heater is labeled as UL Listed and 8'
(2.4m) if the heater is labeled as UL/CUL Listed from
floor, while heater is at a maximum 30 degrees.
Adjacent Heaters to be installed no less than 3'
(0.9m) apart.
Do NOT operate within 25' (7.6m) of flammable/
explosive material.
Never block heater.
Heaters greater than 240 Volts are for “Commercial
Use Only. Risk of fire. Do not use as a residential or
household heater.”
A means for disconnection of the appliance must
be incorporated in accordance with the local wiring
codes.
Do not use if the heating element is damaged or
cracked.
Not for use as a replacement for forced air/
ductless heating.
• Do not leave powered heaters unattended.
Do not run heaters for more than 4 hours at a time
without a 15-minute cool down period between uses.


Produkt Specifikationer

Mærke: Infratech
Kategori: Varmeapparat
Model: 21-5080

Har du brug for hjælp?

Hvis du har brug for hjælp til Infratech 21-5080 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Varmeapparat Infratech Manualer

Infratech

Infratech 21-5080 Manual

5 December 2024

Varmeapparat Manualer

Nyeste Varmeapparat Manualer

Lavex

Lavex 761AMLV75 Manual

15 Juni 2025
XPower

XPower A-12 Manual

15 Juni 2025
BEKO

BEKO RHO8323BT Manual

14 Juni 2025
XPower

XPower B-55 Manual

14 Juni 2025
XPower

XPower B-2 Manual

14 Juni 2025
XPower

XPower M-27 Manual

14 Juni 2025
XPower

XPower P-80 Manual

14 Juni 2025