InSinkErator C1300 Manual


Læs gratis den danske manual til InSinkErator C1300 (7 sider) i kategorien Vanddispenser. Denne vejledning er vurderet som hjælpsom af 22 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 11.5 anmeldelser. Har du et spørgsmål om InSinkErator C1300, eller vil du spørge andre brugere om produktet?

Side 1/7
InSinkErator
Emerson Electric Co.
4700 21st Street
Racine, WI 53406-5093
USA
Sales/Service Tel: 800-845-8345
www.insinkerator.com/worldmap.html
InSinkErator
Suite 6, Building 6
Hatters Lane, Croxley Green Business Park
Watford WD18 8YH
United Kingdom
Sales Tel: (0) 1 923 297 880
Service Tel: (0) 800 389 3715
www.insinkerator.co.uk
InSinkErator
471 Mountain Highway
Bayswater Vic 3153, Australia
Sales Tel: 61 03 9720 5599
Service Tel: 1 300 136 205
www.insinkerator.com.au
Emerson Trading (Shanghai) Co., Ltd.
InSinkErator China Operations
11th Floor, Innov Tower
1801 Hong Mei Road, XuHui District
Shanghai 200233, P.R. China
Fax: 86-21-3367-8121
www.insinkerator.com.cn
Emerson Electric de Mexico, S.A. de C.V.
Calle 10 No. 145
Colonia San Pedro de los Pinos
Delegación Álvaro Obregón
Código Postal 01180
xico D.F.
Sales/Service Tel: 52 (55) 5809 5099
www.insinkerator.es
Emerson FZE
Jebel Ali Free Zone
InSinkErator – MEA
P.O. Box 17033
Dubai, United Arab Emirates
Sales Tel: 9714 8118282
Service Tel: 971 55 498 3985
Email: Mohamed.Karam@emerson.com
The Emerson logo is a trademark and service mark of Emerson Electric Co. Printed in U.S.A.
InSinkErator® may make improvements and/or changes in the specifications
at any time, in its sole discretion, without notice or obligation and further
reserves the right to change or discontinue models.
© 2016 InSinkErator, InSinkErator® is a business unit of Emerson Electric Co. All Rights Reserved.
44872 REV B
www.insinkerator.com/foodservice
Installation Manual
English
Manual de instalación
Espol
Manuel d’installation
Fraais
Manual de Instalão
Português
安装手册
中文
2
8
14
20
26
C1300-SS
H1300-1, -2
steaming
hot water
system
Installation
Manual
4 5
Electric Shock Hazard: To prevent electrical shock, disconnect power before servicing
unit. Use only a properly earthed (grounded) and polarized electric outlet.
Scalding Hazard: Do not allow water
to boil. May result in severe burns.
Only use mild cleaners to clean the tap
and plastic components.
Cleaners with acids, abrasives, alkaline,
and organic solvents will result in
deterioration of the plastic components
and void the warranty.
CLEANING THE TAP AND TANK
Anytime the steaming hot water tap is not used for
extended periods of time, unplug and drain unit. If
it is below freezing you will need to unplug the unit
and drain it.
Disconnect power from unit (unplug unit).
Push hot water tap lever and allow water
to flow until it is cool.
Shut the cold water tap off at the valve.
Disconnect tubes from the tank.
Unhook tank from wall.
Hold tank upside down and drain the
water into the sink.
Towel dry any water drippings from
tank area.
Reinstall tank to wall and
reconnect tubes.
Remove and discard filter cartridge,
if applicable.
To put back into working order, install
new filter cartridge (if applicable) and
turn on cold water supply at valve.
Depress the hot water dispenser faucet
lever and hold until water flows from the
spout. Reconnect the electrical cord.
Factory temperature pre-set is
200˚F (93˚C). To reset the
thermostat to 200°F (93°C), turn
the indicator one notch to the
right of vertical. After adjusting,
depress the tap handle for 20
seconds for water to re-heat to the
new setting.
To adjust water temperature, turn thermostat
dial on the front of the tank clockwise to
increase temperature or turn anticlockwise
to decrease temperature. Repeat if
necessary. All changes should be minimal.
Replace filter cartridge when there is an obvious
decrease in water flow to the tap or if there is an
objectionable taste or odor to the water.
When the inlet and outlet ports have been closed
and the filter’s internal pressure has been relieved,
water (about 2oz; 60ml) will discharge from vent line.
If the new filter cartridge cannot be inserted,
insert the old one and turn until it stops, remove it
and then retry the new cartridge.
The disposable filter cartridge MUST be replaced
every 6 months, at the rated capacity or sooner if a
noticeable reduction in flow rate occurs.
FILTER GUIDE AND REPLACEMENT
Filter replacement instructions:
Replace with an InSinkErator® filter.
Place pan or dish towel under the filter to
catch water drainage during change.
Slowly turn the cartridge anticlockwise
completely until it stops (1/4 turn).
Pull cartridge straight down and discard.
Insert new cartridge into filter head.
Top surface of cartridge will become
flush with the bottom of the filter head
when fully engaged.
Turn the cartridge clockwise until it stops
(1/4 turn).
Open tap to expel trapped air.
Run water for 3 minutes before usage.
SEASONAL STORAGE/DRAINAGE
CARE AND USE
approx.
200°F (93°C)
ADJUSTING THE THERMOSTAT
Personal Injury:
Regularly check for signs of corrosion by
examining the appearance of the dispensed water
every three (3) months.
If there is any discoloration or rusty appearance,
unplug and drain unit as described in the Seasonal
Storage/Drainage section on this page of the
manual.
If the water discoloration remains after draining
and refilling unit, discontinue use and contact an
authorized InSinkErator service agent.
Property Damage: Do not use an extension cord set with
the dispenser. (A standard grounded outlet within 30"
(760mm) of the dispenser is required under the sink.)
FILL TANK & THEN CONNECT POWER
NOTICE
Check all connections to ensure they
are tight and that there are no leaks.
Plug in instant hot water tank. Ensure that
green light on front of tank is illuminated.
(H1300 model only).
Water will be cold at first.
Allow 12-15 minutes for water to reach target
temperature.
Gurgling or hissing is normal during the initial
heating cycle.
A
B
From water
supply line To tap
From water
supply line
To tap
INSTALLING FILTRATION (OPTIONAL)
See Filtration System Installation Instructions for details and specifications
Plug
From filter or
water supply line
NOTICE
NOTICE
A
B
C
D
Mount tank vertically; DO NOT over-tighten screws.
Pre-drill 1/8" (3mm) pilot holes at marks.
Turn screws into pre-drilled holes,
leaving 1/4" (6.35mm) exposed.
Hang the tank on the screws.
Tighten the screws with only 1/2
turn clockwise.
Screws provided are for use in wood studs or
cabinets only. Use wall anchors (not supplied)
for installation into plasterboard.
CONNECTING TAP TO TANK
MOUNTING THE TANK
Select a spot under the sink to mount
tank vertically within reach of both
plumbing and electrical connections.
The tank should be within 16" (400mm) or
less of tap water lines and within
30" (760mm) or less of a standard earth
(grounded) outlet.
While holding tank in place on the spot
selected for installation, use a pencil to
mark locations for 2 hanging screws.
Property Damage: Tank must be located within
16" " (400mm) of tap and within 30 (760mm) or
less of a standard earth (grounded) outlet. DO NOT
extend plumbing or electrical lines.
Without depressing the grey button,
place the snap-connect fitting at the
end of the tube onto the left blue
plastic fitting on the tank, pushing until
it clicks into place. (1)
Slip the large white tube over
barbed middle fitting and slide down
approximately 1/2" (13mm). (2)
Slip the small white tube over the
far right smooth fitting and slide down
approximately 1/2" (13mm). (3)
Visually check for pinched or
crimped tubes.
Hose clamps are not needed for any of the connections.
Tank must be
mounted level
to ensure
proper operation.
Leave 1/4" (6.4mm)
for hanging tank.
Property Damage: Pinched or blocked water lines
may cause damage to the water tank. Check to
make sure tubes are connected properly and are
pushed on as mentioned.
3 5
4
(1) (2) (3
)
NOTICE
NOTICE
A
A
B
Personal Injury: Do not locate filter above an
outlet or other electrical device. Install head and bracket
so that connections require no stretching, kinking or
pinching of tubing.
Separate cartridge from filter head.
Mark hole locations for filter head
and bracket in a spot that allows
for filter replacement.
Drill 1/8" (3mm) starter holes and attach
bracket to wall with wood screws, turning
until snug.
Insert cartridge into filter head. Top surface
of cartridge will become flush with bottom
of filter head when fully engaged.
Screws provided are for use in wood
studs or cabinets only. Use wall anchors
(not included) for installation into drywall.
Property Damage: Tube runs need to form to the
cabinets contours to allow storage space with no sharp
bends. Tubes need clean, perpendicular,
burr-free cuts to ensure a true fit.
Determine length of tubing required,
then cut to length making sure the cut is
perpendicular and burr-free.
Insert a white 1/4" (6.35mm) tube into
inlet side of filter head until it stops.
Press in again to ensure a secure fit.
Insert the other white 1/4" (6.35mm) tube
into outlet side of filter head until it stops.
Press in again to ensure a secure fit.
Property Damage: Do not extend the lines farther
than the 16" (40cm) provided. Ensure tube(s) and
“Y” connnector are securely fit.
Insert the copper tubes(s) from the
dispenser into “Y” quick-connector using
the plug for hot-only models.
Connect the " (6.35mm) tube white 1/4
from the right outlet on the filter head into
the quick-connect fitting until it stops.
Press in again to ensure a secure fit.
To remove tube(s) or plug from quick-connector,
depress the release ring and gently pull away.
It is normal for approximately 2 oz. (60ml). of water
to discharge when filter is removed.
Connect remaining white 1/4"
(6.35mm) tube to incoming water
supply line.
Scalding Hazard: The faucet dispenses near-boiling
(210ºF; 98ºC) water which can instantly cause scalds or
burns. Use care when operating this appliance.
Turn on the water supply.
Depress the dispenser’s handle HOT
and hold it until water flows from the
spout (approximately 1 to 2 minutes).
For the F-1000S and F-1000, flush
2.25 gallons (8.5L) through filter before
use (approximately 3 minutes). For the
F-2000S and F-2000, flush 3 gallons (11.4L)
through filter before use (approximately 4
minutes).
Check all connections to ensure they are
tight and that there are no leaks.
6
7
FINAL WATER CONNECTION
Property Damage: Join remaining tube
to cold water supply only.
Install a T-fitting onto the cold (not included)
water supply line.
Install a dedicated water control valve
(not included) with 1/4" (6.35mm)
compression fitting.
At the end of the 1/4" (6.35mm) tube white
from the quick-connector, slide the supplied
brass nut and ferrule over the tube and then
push in the brass tube insert.
Insert the 1/4" (6.35mm) tube into the white
1/4" (6.35mm) compression fitting
and tighten.
With Filter System
A
NOTICE
1/4 "
(6.35mm)
Plastic
Tube
Brass
Nut Brass
Insert
Ferrule
Property Damage: Join remaining tube
to cold water supply only.
Install a T-fitting (not included) onto the cold
water supply line.
Install a dedicated water control valve with
1/4" (6.35mm) compression fitting (not included).
At the end of the 1/4" (6.35mm) tube, copper
slide the brass nut and ferrule, provided with the
control valve, over the tube.
Insert the copper tube into the 1/4" (6.35mm)
compression fitting and tighten.
Without Filter System
A
NOTICE
1/4 "
(6.35mm)
Copper
Tube
Brass
Nut Ferrule


Produkt Specifikationer

Mærke: InSinkErator
Kategori: Vanddispenser
Model: C1300

Har du brug for hjælp?

Hvis du har brug for hjælp til InSinkErator C1300 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Vanddispenser InSinkErator Manualer

InSinkErator

InSinkErator C1300 Manual

16 August 2024

Vanddispenser Manualer

Nyeste Vanddispenser Manualer