Læs gratis den danske manual til Intermatic IG3240RC3 (6 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 18 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 9.5 anmeldelser. Har du et spørgsmål om Intermatic IG3240RC3, eller vil du spørge andre brugere om produktet?

Side 1/6
Main Breaker
2-Pole, 20 A circuit
breaker shown
A=Black (Line)
B=Black (Line)
C=Neutral (White)
D=Green (Ground)
Line
Line
Neutral
GREEN
WHITE
BLACK
BLACK
120 V
120 V
120 V
240 V
120 V
Figure 1
Type 1 Installation
Figure 2
Type 2 Installation
Type 1 installation:
A typical installation of a Type 1 SPD will be connected between the secondary of the service transformer and the line side of the service
panel. This installation is intended to be installed without overcurrent protection to the SPD.
1. Determine location:
Ensure conductor lengths are as short and straight as possible for best performance. Do not coil excess wire. The SPD functions
best if all bends in wires are rounded, ideally to a 4” radius. Hard 90 degree bend will reduce efficiency. Cut all leads to the correct
length. Do not coil excess leads.
Install appropriate weatherproof fittings if the unit is to be mounted outside.
2. Connect wires as shown in figure 1.
3. Ensure all mounting and connections are correct and secure. Once energized the green indicator LED will be ON and visible through
the cover of the SPD.
Type 2 installation:
A typical installation of a Type 2 SPD will be connected to the load side of the service panel and is intended to be installed with overcurrent
protection to the SPD.
1. Determining location:
Ensure conductor lengths are as short and straight as possible for best performance. Do not coil excess wire. The SPD functions
best if all bends in wires are rounded, ideally to a 4” radius. Hard 90 degree bend will reduce efficiency. Cut all leads to the correct
length. Do not coil excess leads.
Install appropriate weatherproof fittings if the unit is to be mounted outside.
IG3240FMP33 is also available for flush mount applications.
2. Connect the green wire from the SPD to the ground bus in the panel.
Connection may also be made to the neutral/ground bus bar if panel does not have a separate ground bus bar.
3. Connect the white wire from the SPD to the neutral bus bar in the panel as shown in figure 2.
4. Connect the two black wires to a circuit breaker as shown in figure 2. For best performance from SPD, the maximum recommended
circuit breaker size of 240 V, 20 A, 2-pole should be used.
5. Ensure all mounting and electrical connections are correct and securely fastened. Once energized, the green indicator LED will be ON
and visible through the cover of the SPD.
Maintenance:
AC Voltage SPD:
Periodically check SPD to ensure green indicator LED is ON. If green LED is OFF, protection has diminished and the SPD should be
replaced immediately.
INSTALLATION INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS • SAVE THESE INSTRUCTIONS
Model IG3240RC3
Type 1 or Type 2 Surge Protection Device (SPD)
For Indoor/Outdoor use.
Disconnect power at the circuit breaker(s) or disconnect switch(es) before installing or servicing.
Installation and/or wiring must be in accordance with national and local electrical code requirements.
Installation and service to be performed by a qualied licensed technician or electrician.
Suitable for use on a circuit capable of delivering not more than 50,000 rms symmetrical amperes.
For outdoor locations or wet locations (rain-tight), conduit hubs that comply with requirements of the UL514B (standard for tting
conduit and outlet boxes) are to be used.
WARNING
Risk of Fire or Electric Shock
NOTICE
NOTICE
NOTICE
NOTICENOTICE
Thoroughly read instructions before installing SPD Unit. This unit contains no serviceable parts.
This product does not protect against direct lightning strikes.
Page 1


Produkt Specifikationer

Mærke: Intermatic
Kategori: Ikke kategoriseret
Model: IG3240RC3

Har du brug for hjælp?

Hvis du har brug for hjælp til Intermatic IG3240RC3 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Intermatic Manualer

Intermatic

Intermatic EK4536 Manual

12 November 2025
Intermatic

Intermatic LC4521C Manual

11 November 2025
Intermatic

Intermatic OP2GY24 Manual

8 November 2025
Intermatic

Intermatic OP2BK24 Manual

6 November 2025
Intermatic

Intermatic WP1250MXD Manual

5 November 2025
Intermatic

Intermatic OP2BK18 Manual

4 November 2025
Intermatic

Intermatic WP1030MXD Manual

4 November 2025
Intermatic

Intermatic OP5BK24 Manual

4 November 2025
Intermatic

Intermatic OP5GY24 Manual

4 November 2025

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Topping

Topping DX5 Manual

4 December 2025
CyberPower

CyberPower GX150C2 Manual

4 December 2025
SPT

SPT SM-1024K Manual

4 December 2025
Novy

Novy 990037 Manual

4 December 2025
D&R

D&R Hybrid-2 Manual

4 December 2025
Iogear

Iogear GHDSW4K3 Manual

4 December 2025
Vevor

Vevor WK320016-1 Manual

4 December 2025
ELO

ELO E426554 Manual

4 December 2025