Power Tap Installation Guide
Intermatic KPT Series
SAFETY SECTION
Warning
Risk of Fire or Electric Shock
• Disconnect power at the circuit breaker(s) or disconnect switch before installing or servicing.
• Thoroughly read instructions before installing unit.
• The line voltage to the receptacle must be 120 VAC as indicated on the label of the Power Tap.
• Installation and/or wiring must be in accordance with national and local electrical code requirements
• Unused wire leads must be capped before installation.
• A photocontrol or shorting cap must be installed to ensure water does not enter Power Tap.
• Power Tap does not provide a ground connection. If device requires grounding, other provisions must be made to ensure proper grounding.
• Power Tap contains no serviceable parts.
PRODUCT DESCRIPTION
KPT0170 Power Tap
The Intermatic Model KPT0170 Power Tap is a receptacle that is used to tap into the electric power feed of a lighting fixture
through its ANSI C136.10 (3-pin) or C136.41 (7-pin) style receptacle. The Power Tap meets all applicable requirements of
ANSI C136.10 and C136.41. It taps into the electrical power feed without disturbing the function of the light fixture’s control
device. The Power Tap comes with a 16 AWG flush cut cable end. The Power Tap contains no serviceable parts and is
intended for outdoor use.
Ratings:
• 120 VAC
• 15 A max total, 5 A max on line out
• 5 A from -40 °C to 50 °C, derate at 0.1 A/°C above 50 °C up to 70 °C max
• 50/60 Hz
POWER TAP INSTALLATION
Connect and Install an External Device
1. Connect the power feed cable from the Power Tap to the device per the manufacturer’s instructions for the device.
Note: The Power Tap does not provide a ground connection. If the device requires grounding, other provisions must be
made to ensure proper grounding.
2. Install the external device on the light pole or light pole arm as directed by the manufacturer of the device or by using the
device installation guidelines.

2
Power Tap Installation Guide
Install the Power Tap
1. Disconnect power at the circuit breaker(s) or disconnect the switch(es) before installing.
2. If present, remove the photocontrol or control node from the existing receptacle.
3. Insert the Power Tap into the receptacle by aligning the prongs on the Power Tap with the openings in the receptacle.
Push down on the Power Tap and twist clockwise to lock. The Power Tap must be locked in place.
4. Re-install the photocontrol, shorting cap, or control node device onto the Power Tap top receptacle.
5. Fasten the Power Tap cable to the light pole or light pole arm (per the regulations appropriate for your application) to
ensure the cable is secure and that no undue stress is placed on the receptacle and light fixture.
6. Reconnect power at the circuit breaker(s), or reconnect the switch(es).
Photocontrol
KPT0170 Power pTa
Receptacle
Grounding
Wire
Properly secure cable
from Power pTa
Device
FIG. 1. Install Power Tap
LIMITED WARRANTY
Warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased or (b) completing a warranty claim online
at www.intermatic.com. This warranty is made by: Intermatic Incorporated, Customer Service 1950 Innovation Way, Suite 300, Libertyville, IL 60048. For
warranty service go to: http://www.Intermatic.com or call 815-675-7000.
158--02200REF
Produkt Specifikationer
Mærke: | Intermatic |
Kategori: | Ikke kategoriseret |
Model: | KPT0170 |
Har du brug for hjælp?
Hvis du har brug for hjælp til Intermatic KPT0170 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Ikke kategoriseret Intermatic Manualer

8 Juni 2025

8 Juni 2025

8 Juni 2025

7 Juni 2025

7 Juni 2025

7 Juni 2025

7 Juni 2025

28 Januar 2025

5 Januar 2025

5 Januar 2025
Ikke kategoriseret Manualer
- Ikke kategoriseret Tams Elektronik
- Ikke kategoriseret RCA
- Ikke kategoriseret Wampler
- Ikke kategoriseret Dunlop
- Ikke kategoriseret Spypoint
- Ikke kategoriseret Maul
- Ikke kategoriseret OJ ELECTRONICS
- Ikke kategoriseret Cavius
- Ikke kategoriseret Warwick
- Ikke kategoriseret Mr Steam
- Ikke kategoriseret Wago
- Ikke kategoriseret Step2
- Ikke kategoriseret Bang And Olufsen
- Ikke kategoriseret Metalux
- Ikke kategoriseret Chimera
Nyeste Ikke kategoriseret Manualer

8 Juni 2025

8 Juni 2025

8 Juni 2025

8 Juni 2025

8 Juni 2025

8 Juni 2025

8 Juni 2025

8 Juni 2025

8 Juni 2025

8 Juni 2025