Intermatic PF1202T Manual


Læs gratis den danske manual til Intermatic PF1202T (4 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 31 personer og har en gennemsnitlig bedømmelse på 4.9 stjerner ud af 16 anmeldelser. Har du et spørgsmål om Intermatic PF1202T, eller vil du spørge andre brugere om produktet?

Side 1/4
FREEZE PROTECTION
FOR POOLS, SPAS
AND TER FEATURESWA
By
FREEZE PROTECTION FOR POOLS AND SPAS
By ®
INSTALLATION
OPERATION &
SERVICE MANUAL
MODEL: PF1202T
TWO CIRCUIT POOL EQUIPMENT CONTROL
WITH FREEZE PROTECTION IN RAINPROOF ENCLOSURE
ELECTRICAL RATING: 3 HP MAX. - 240 VOLT, 60 HZ.
SUITABLE FOR POOL/SPA EQUIPMENT CONTROL
DANGER! To Reduce the Risk of Injury:
...do not permit children to operate the Control Unit or use the Pool/Spa unless they are closely supervised at all times.
...test GROUND FAULT protection regularly. If it fails to reset, DO NOT USE THE POOL or SPA! Contact a qualified
service technician.
...always disconnect electricity before servicing this control or the equipment(s) connected to it. THIS CONTROL IS NOT
TO BE USED AS A POWER DISCONNECT.
READ, FOLLOW & SAVE THIS INSTRUCTION MANUAL
GENERAL INFORMATION
This Pool Equipment Control is designed to automatically operate the Filter Pump, Cleaner Pump
and also to provide freeze protection for the pool equipment. Nevertheless this product is not
intended to be a substitute for insulation, coverings, or maintenance.
THE FILTER PUMP TIME SWITCH is located in the upper left side of the enclosure and operates
the Filter Pump, as set by the trippers on the yellow dial, on a 24 hour schedule. For setting the
schedule, refer to page 3 of this Manual.
THE CLEANER PUMP TIME SWITCH is located in the upper right side of the enclosure and
operates the Cleaner Pump (Booster Pump). The trippers of this
Time Switch should be set so that the operation of the
Cleaner Pump falls within the operation of the
Filter Pump. To avoid equipment damage, the two
Time Switches are interlocked and the Cleaner
Pump would not operate unless the Filter Pump
is already operating.
THE FREEZE PROTECTION THERMOSTAT is
located in the lower left side of the enclosure
and turns ON the Filter Pump when the air
temperature (where the Control Panel is located)
drops below the temperature set by the dial
(between 32˚F and 45˚F).


Produkt Specifikationer

Mærke: Intermatic
Kategori: Ikke kategoriseret
Model: PF1202T

Har du brug for hjælp?

Hvis du har brug for hjælp til Intermatic PF1202T stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Intermatic Manualer

Intermatic

Intermatic EK4536 Manual

12 November 2025
Intermatic

Intermatic LC4521C Manual

11 November 2025
Intermatic

Intermatic OP2GY24 Manual

8 November 2025
Intermatic

Intermatic OP2BK24 Manual

6 November 2025
Intermatic

Intermatic WP1250MXD Manual

5 November 2025
Intermatic

Intermatic OP2BK18 Manual

4 November 2025
Intermatic

Intermatic WP1030MXD Manual

4 November 2025
Intermatic

Intermatic OP5BK24 Manual

4 November 2025
Intermatic

Intermatic OP5GY24 Manual

4 November 2025

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Topping

Topping DX5 Manual

4 December 2025
CyberPower

CyberPower GX150C2 Manual

4 December 2025
SPT

SPT SM-1024K Manual

4 December 2025
Novy

Novy 990037 Manual

4 December 2025
D&R

D&R Hybrid-2 Manual

4 December 2025
Iogear

Iogear GHDSW4K3 Manual

4 December 2025
Vevor

Vevor WK320016-1 Manual

4 December 2025
ELO

ELO E426554 Manual

4 December 2025