Læs gratis den danske manual til Intermatic T30604R (4 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 11 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 6 anmeldelser. Har du et spørgsmål om Intermatic T30604R, eller vil du spørge andre brugere om produktet?

Side 1/4
Many of today’s energy efficient pools and spas utilize the benefits of the two stage water circulation
principal. For example, while the daily cleaning process requires high pressure and fast turnover of
a large amount of water in the morning, the heating,
either by the sun or a heater, is more energy efficient
on a slower flow rate during the day. Also, some of
the new water sanitation techniques require longer
dispensing time of ozone or chemicals.
The most economical way to operate a pool or spa
is by the use of a two speed filter pump, together
with this reliable, simple to install, simple to operate
Two Speed Pump Control.
This Control is designed to automatically operate
a two speed pump on a daily schedule. The
all-weather enclosure contains two heavy duty,
industrial grade time switches. In addition, the
enclosure has a provision to install switches or a
GFCI receptacle on the side as well as inside the
enclosure. The time switch on the right is intended
for starting and stopping the pump and the time
switch on the left is for changing the speed (RPM)
of the pump while it is running. The mechanism on
the right can also accommodate an optional heater
control (Fireman) switch.
Model: T30604R
TIME CONTROL FOR TWO SPEED POOL/SPA FILTER PUMPS FOR INDOOR/OUTDOOR USE
ELECTRICAL RATING: 5 H.P. Max. - 240 Volt - 60 Hz.
Maximum running load not to exceed 28 Amperes.
Suitable for Pool Equipment Control and for Direct Conduit Connection to a
Wet-Niche or No-Niche Underwater Luminaire
DANGER! TO AVOID RISK OF INJURY:
...do not permit children to operate the Control Unit or use the Pool/Spa unless they are closely supervised at all times.
...test GROUND FAULT protection regularly. If it fails to reset, DO NOT USE THE POOL or SPA!
Contact a qualified service technician.
...always disconnect electricity before servicing this control or the equipment connected to it. THIS CONTROL IS NOT TO BE
USED AS A POWER DISCONNECT.
READ, FOLLOW AND SAVE THIS INSTRUCTION MANUAL
GENERAL INFORMATION
IMPORTANT SAFETY INSTRUCTIONS
When installing and operating this electrical control and other associated equipment, basic safety precautions should always be followed,
including the following:
1. Read and follow all instructions.
2. This Control must be installed by a qualified electrician, according to National and Local Electrical Codes.
3. Install this control not less than 5 feet (3 meters in Canada) from inside edge of pool. USE COPPER CONDUCTORS ONLY.
4. Do not exceed the maximum ratings of individual components, wiring devices, and current carrying capacity of conductors.
5. For grounding and bonding this Control and the installation, refer to Article 680 of the National Electrical Code.
6. The Control should not operate any equipment which would cause bodily injury or property damage should it be activated unexpectedly.
READ, FOLLOW AND SAVE THIS INSTRUCTION MANUAL
1
T30604R SERIES
POOL/SPA EQUIPMENT CONTROLS
INSTALLATION
OPERATION &
SERVICE MANUAL
INSTALLATION
1. Remove the four #10 hex head screws from the
back of the enclosure and attach mounting brackets
to enclosure.
2. Select the proper location for the Control and hang
enclosure on a flat vertical surface or other support,
using hardware suitable for the purpose.
3. Prepare the necessary conduit runs, terminate them
at both ends and pull-in the conductors as specified
by the installation layout.
*If this control is used for direct conduit connection
to a wet niche or no niche luminaire, order one of
the following: 156PA13713A for a 1/2” non-metallic
kit, 156PA13714A for a 3/4” non-metallic kit,
156PA13715A for a 1” non-metallic kit, or
156PA14336A for a 1/2” metallic kit.
4. Refer to Figure 1 below. Note that this enclosure
contains two independent time switches. The one on
the left is a , a Single Pole DoubleModel T106M
 Throw(SPDT)switch,andit’sfunctionistochange
the speed (RPM) of the pump motor. The time
switch on the right is a , a DoubleModel T104M
 PoleSingleThrow(DPST)switch,andit’s
function is to the start/stop
pump motor. To wire the
two switches, follow wiring
diagram on page 4 of this
manual. Make sure that
connections to time switch terminals are tight
(25 lb. - in. minimum) and insulation clears the
pressure plate - see illustration.
a. Remove clock motor leads from Terminals A and 3 of
T106M .and connect to Terminals 1 and 3 of T104M
Connect LINE 1 to and L to Terminal 1 INE 2 Terminal 3
of T104M.
b. Install jumpers between Terminals 1 and 4 of T106M
and between and Terminal 2 of T104M Terminal 1 of
T106M.
c. Connect COMMON of Two Speed Pump to Terminal 4
of T104M Terminal 2 of T106M, LOW to and HIGH to
Terminal 3 of T106M.
d. Connect green grounding conductors to the Equipment
Grounding Terminal at bottom of enclosure.
5. If required by the heater manufacturer, install
fireman switch kit 156T4042A (not furnished) on
Time Switch Plate and make the fireman switch
connections.
Use at least #18
AWG wiring with
insulation rated
300 Volt or higher.
Place heater
ON/OFF switch
on heater to ON.
6. To install additional wiring devices inside the
enclosure, first remove rectangular knock-out(s) in
dead front. Next, remove hex head screws in back of
enclosure and install stand-offs* in place of screws.
Attach wiring device to stand-offs.
Stand-offs are not furnished. Order 21T156A for a set of
four (4) stand-offs and mounting hardware.
7. If external bonding is required, install bonding lug(s)
on bottom of enclosure (156T11047A may be
ordered) and bond installation according to code
requirements.
8. Testing of the installation is optional and
recommended only if pump is securely in place
and will not be damaged by the following test:
a. Turn the manual level of the time switches to OFF.
b. Turn ON power at breaker panel.
c. Move the manual lever of T104M to the right (ON).
Pump should start and run on low speed.
d. Move the manual lever of T106M to the right (ON).
Pump should now be running on high speed.
e. Move the manual lever of T104M to the left (OFF).
Pump should stop running.
In case of unsatisfactory results, turn OFF power,
check your wiring, refer to Troubleshooting on Page 4.
9. Install front panel over wiring compartment.
The control is now ready for programming,
Keep door closed at all times.
2
Figure 1
PRESSURE PLATE
TERMINAL SCREW
MAKE SURE INSULATION
CLEARS PRESSURE PLATE
WARNING: Do not disconnect high limit or pressure switches.


Produkt Specifikationer

Mærke: Intermatic
Kategori: Ikke kategoriseret
Model: T30604R

Har du brug for hjælp?

Hvis du har brug for hjælp til Intermatic T30604R stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Intermatic Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Hozelock

Hozelock 5102 Manual

2 August 2025
ART

ART 310 Manual

2 August 2025
Navman

Navman MY450LMT Manual

2 August 2025
Navman

Navman MiVue 745 Manual

1 August 2025
Hitachi

Hitachi WR22SE Manual

1 August 2025
Synology

Synology M2D20 Manual

1 August 2025
Buffalo

Buffalo GC882 Manual

1 August 2025