Irritrol RS1000 Manual


Læs gratis den danske manual til Irritrol RS1000 (12 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 15 personer og har en gennemsnitlig bedømmelse på 4.0 stjerner ud af 8 anmeldelser. Har du et spørgsmål om Irritrol RS1000, eller vil du spørge andre brugere om produktet?

Side 1/12
Wireless RainSensor User’s Guide 1
Table of Contents
Component Overview 2
Quick Start Installation Instructions 3
Detailed Installation Instructions
Mounting the Receiver
Wiring the Receiver
Control Wire Connection
Power Wire Connection
Initial Receiver Testing
4
4
4
4
6
6
Installing the Sensor / Transmitter
Testing the Signal Strength
Installation
Freeze Sensor Installation
7
7
7
7
Wireless RainSensor Operation
Normal Operation
Smart Bypass
Power Down
Receiver Learn Mode
Attention Required
8
8
8
8
8
8
Sensor Adjustment
Battery Replacement
9
9
Changing Sensor/Transmitter Code 9
Troubleshooting 10
Specications 11
Electromagnetic Compatibility 12
Technical Support Numbers 12
Congratulations on your purchase of the Irritrol Systems Wireless RainSensor. The
Wireless RainSensor components are designed for easy installation, so your sensor
controlled irrigation system will be up and running in minutes.
Before attempting the installation, please read through these instructions in their
entirety, and refer the installation instructions for your irrigation system controller/timer
in regards to connecting a rain sensor or rain switch. The Wireless RainSensor is
designed to work with either Normally Open or Normally Closed sensor circuits.
: Please note the following information regarding installation and use of Important
the Wireless RainSensor components:
The RainSensor Receiver Module is designed to operate with 24 VAC power
only. Connecting the receiver wiring to 120/240 VAC power may result in severe
equipment damage.
Installation methods must comply with all applicable national and local building
codes. If you are unsure about proper wiring practices, have a qualied contractor
perform the installation for you.
The Receiver cover should always be used when the Receiver is installed outdoors.
The Sensor/Transmitter should never be submerged in water or installed inside a
rain gutter.
Introduction
Wireless RainSensorTM
Models RS1000 & RFS1000 (+Freeze)
User’s Guide
RS1000
SENSOR STATUS
SIGNAL
POWER
Blinking Bypass ON
Blinking Attn. Reqd.
SENSOR STATUS
PRESS
Receiver
Sensor/Transmitter
2 Wireless RainSensor User’s Guide
Receiver (Figure 1)
1 - Weather-resistant Cover:
Slides upward to remove. Protects
the receiver module when located
outdoors. Keep the cover installed
at all times other than when
manually operating the receiver.
2 - Sensor Status Indicator:
Steady light - Sensor is active
(either rain or freeze).
Blinking light - Indicates receiver
has been bypassed for one rain
cycle. Smart Bypass™ button
pressed once. Press again to exit
bypass mode.
3 - Smart Bypass™ Button:
Press to temporarily override the
sensor when active.
Press and hold for 5–7 seconds to
turn o󰀨 the receiver.
4 - Power Indicator:
Steady light - 24 VAC power is connected.
Blinking light - Sensor/Transmitter battery power low, or other communication
problem.
No light - Unit is o󰀨 or is disconnected from 24 VAC.
5 - Signal Indicator: Indicates quality of last received signal.
Steady light - good signal.
Blinking light - fair signal.
No light - poor signal (relocate Sensor Transmitter).
6 - Multi-wire Cable - 20” (50 cm) color-coded wires provided for controller
connections.
Sensor/Transmitter (Figure 2)
1- Spindle - Press down and hold to
manually test transmitter operation.
2- Rainfall Adjustment Cap - Adjusts
the Sensor/Transmitter to signal
the receiver when the accumulated
rainfall reaches 1/8” (3 mm), 1/4” (6
mm), 1/2” (13 mm), 3/4” (19 mm) or
1” (26 mm).
3 - Vent Ring: Adjust “dry-out” rate.
4- Universal Mounting Bracket
with Quick-Clip™ - Simplies
installation on rain gutter, or
roof eaves, fences, etc. Sensor/
Transmitter adjusts easily to the
vertical position.
5 - Conduit Adapter: Alternate
mounting option for conduit mount.
6- Antenna Wire - Straighten downward
for maximum range.
Component Overview
1
2
3
4
Figure 2
5
6
RS1000
SENSOR STATUS
SIGNAL
POWER
Blinking Bypass ON
Blinking Attn. Reqd.
SENSOR STATUS
PRESS
1
2
3
45
6
Figure 1


Produkt Specifikationer

Mærke: Irritrol
Kategori: Ikke kategoriseret
Model: RS1000

Har du brug for hjælp?

Hvis du har brug for hjælp til Irritrol RS1000 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Irritrol Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer