Læs gratis den danske manual til Jablotron JA-63K (8 sider) i kategorien Sikkerhed. Denne vejledning er vurderet som hjælpsom af 10 personer og har en gennemsnitlig bedømmelse på 4.9 stjerner ud af 5.5 anmeldelser. Har du et spørgsmål om Jablotron JA-63K, eller vil du spørge andre brugere om produktet?

Side 1/8
Alarm system JA-63 „Profi“ - 8 - MGK51503
2.9 Subsystem arming
In a large building a sub control panel can be enrolled to the JA-63. The
subsystem reports all alarms and failures to the main system.
The installer can program if the systems will be armed and disarmed separately
(by their own codes and remote controls) or if the main control panel will rule the
sub control panel. Ask your installer for explanation on how to operate your
system if a sub control is panel installed.
2.10 Appliance control
The system can be used to control an electrical appliance (light, heating,
ventilation etc.). In such a case users can operate the device:
Locally with keypad* – entering F81 (ON) or F80 (OFF).
Remotely by phone keypad or by SMS messages – the control panel
must be equipped with GSM communicator for this feature
* Installer can program that this feature will work only when the entry is followed by a user code.
3 User’s settings
Following section is designated for the system supervisor, who knows the
master code.
All programming sequences can be terminated before completed (by N key).
3.1 New master code
The master code is used by the supervisor. The factory default master code is
1234 and you should program your own four digits code. Code programming is only
possible when the system is disarmed.
To change an existing master code enter:
F 5 xxxx yyyy yyyy
where xxxx is the existing and yyyy is the new master code (new code must be
entered twice to avoid an error).
Example:
Existing code 1234 will change to 6723 entering: F 5 1234 6723 6723
Alarm system JA-63 „Profi“ - 9 - MGK51503
3.2 User codes setting
There can be up to 14 different user codes for individual users. The system stores
to its memory which code was used for what event and when. This data can go to a
Central monitoring station as well and can also be viewed by a PC with Comlink
software.
All user codes are empty as a factory default and the supervisor should program
them entering:
F 6 xxxx yy zzzz
where xxxx is the master code, yy is the user code index (from 01 to 14) and
zzzz is the new user code.
Example:
If the master code is 1234 and the user 3 new code should be 5277 enter:
F 6 1234 03 5277
To delete a particular user code, enter 0000 as the new code (combination
0000 can not be used as a valid code).
Example:
If the master code is 1234 the user 3 code can be deleted by:
F 6 1234 03 0000
Notes:
You can program new codes only when the system is disarmed.
The supervisor should record the codes to the table on last page of this
manual (it should be kept hidden in a safe place).
If the system is split, the supervisor can change the user codes, but can
not change to which section the particular code belongs (only the installer
can change this).
3.3 Internal clock setting
The control panel has a built in real time clock. All events are stored to the event
memory including the time & date. The clock should be set after installation, but
the supervisor can set the clock while in the user mode.
To switch the control panel to the user mode enter F 0 master code. User
mode will be indicated by a U on the keypad. To set the clock enter:
4 hh mm DD MM YY
where: hh = hours; mm = minutes; DD = day; MM = month and YY = year
Example: at 21:30 on March 19. 2005 enter: 4 21 30 19 03 04
To exit user mode press N.
Alarm system JA-63 „Profi“ - 10 - MGK51503
Actions' table
a no splitting split
0 no action no action
1 arm all arm all
2 disarm disarm all
3 partial arming arm A
4 partial arming arm B
5 disarm disarm A
6 disarm disarm B
3.4 Automatic arming / disarming
The system can automatically arm and disarm for a requested period of a day.
While in the user more, up to ten instructions (time & action) can be programmed
in the period of one day.
To switch the control panel to the user mode enter F 0 master code. User
mode will be indicated by a U on the keypad. To program automatic arming enter:
64 n a hh mm
where: n = instruction number from 0 to 9
a = action (see the actions' table)
hh = hours (from 00 to 23)
mm = minutes (from 00 to 59)
Example: to program an automatic complete
arming of the system at 21:15 everyday
enter: 64 0 1 21 15
Notes:
If any automatic action is selected, it will be preformed everyday at the
programmed time, following the internal control panel clock.
The automatic arming and disarming can be overridden manually anytime
(by a user code or a remote control)
If the control panel is in the requested arming mode before the action
time, the programmed action will not change the arming
Factory default setting - all instructions are set for no action
To exit user mode, press the N key.
3.5 Bypass
The supervisor can bypass (switch off) particular zones (potential sources of
alarms) while in the user mode. If a zone is bypassed, it can’t trigger an alarm.
To switch the control panel to the user mode enter F 0 master code. User
mode will be indicated by a U on the keypad.
To set up bypass:
1. Press key 1 to open the bypass menu.
2. With key 1 and 7 you can scroll all potential alarm sources (wireless
detectors are distinguished with the symbol ).
3. Select the source (detector, wired input…) which you want to bypass and:
a. either press key 2 for 2 seconds to bypass the source for the next
arming period (confirmed by flashing Battery LED);
b. or press key 3 for 2 seconds to bypass the source permanently
(confirmed by the Battery LED being permanently lit);
Alarm system JA-63 „Profi“ - 7 - MGK51503
2.5 Home arming
The installer can program particular detectors so that they will be automatically
bypassed in the so called “Home” partial arming. This allows for people to stay in
the particular part of the house after arming. To arm partially:
On the keypad press home arming button
H will indicate the Home partial arming on the keypad.
To disarm a partially armed system - enter your user code or press the or
button on the remote control.
2.6 Door opening
An electrical door lock (if installed) can be controlled via the alarm system.
Press the door opening button on the keypad to release the
lock.
2.7 Alarm memory reading
All events (arming, disarming, alarms, failures…) are recorded into the control
panel’s memory along with the time and date. The complete system history can be
viewed using a PC with Comlink software. Alarms and failures can also be viewed
on the keypad by entering:
F 4 - will show the last recorded alarm or failure. Press key 4 multiple
times to go deeper in to the memory.
2.8 Split system arming
The system can be split by the installer into two independent sections (A,B) and
a shared section (corridors, stairs, a main door…). This allows for a particular user
to arm and disarm only a particular section of the house with his/her code or
remote control (exactly as in a non split system). Arming of sections A and B is
indicated by I I symbols on the keypad. The shared section will be armed
automatically when A and B sections are both armed.
With the master code the supervisor can arm and disarm both sections. If the
master code is entered, the system will arm (if completely disarmed) or disarm (if
any section is armed).
Entering F1 master code will control only section A and F2 master code only
section B (this is true only when fast arming is disabled by the installer).
Note: partial Home arming is not possible if the system is split.