Læs gratis den danske manual til J.P. Instruments EDM-930 (52 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 28 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 14.5 anmeldelser. Har du et spørgsmål om J.P. Instruments EDM-930, eller vil du spørge andre brugere om produktet?

Side 1/52
FAA Approved Installation Manual for the Report No 908
EDM-900 and EDM- 930 Page 1 of K52 Rev
Primary Engine Data Management System Date 5-02- 17
TABLE OF CONTENTS
Section Page
1. Revisions 2______________________________________________________________________________________
2. _________________________________________________________________________________ Read This First 2
3. Instrument Labeling ______________________________________________________________________________ 5
4. Primary TSO Label ______________________________________________________________________________ 5
5. Operation and Abbreviations ______________________________________________________________________ 6
6. Remote Alarm Light EDM 900 7_____________________________________________________________________
7. Locating and Installing the Indicator and Remote Alarm Display (RAD and Alert Light) _______________________ 10
8. EDM-900/930 Key information installation __________________________________________________________ 12
9. Routing the Wiring Harnesses _____________________________________________________________________ 13
10. Pressurized Aircraft wire Routing __________________________________________________________________ 13
11. Power Connection ______________________________________________________________________________ 14
12. Probe Wiring __________________________________________________________________________________ 14
13. Exhaust Gas Temperature Probe (EGT) Installation ___________________________________________________ 15
14. Cylinder Head Temperature (CHT) Probe Installation __________________________________________________ 16
15. Radial Engine CHT (spark plug gasket) _____________________________________________________________ 16
16. Outside Air Temperature (OAT) Probe Installation ____________________________________________________ 16
17. Oil Temperature Probe Installation ________________________________________________________________ 17
18. Oil Pressure Sensor Installation ___________________________________________________________________ 17
19. Fuel Pressure Sensor Installation using combination sensor _____________________________________________ 18
20. Ammeter Shunt Installation _______________________________________________________________________ 19
21. General Fuel Flow Transducer Installation __________________________________________________________ 20
22. ___________________________________________________________________ 22 Fuel Level Sender Wiring Types
23. _______________________________________________________________ 28 Fuel Flow Totalizer, Refuel Question
24. GPS Interface _________________________________________________________________________________ 28
25. Manifold Pressure (MAP) Sensor __________________________________________________________________ 28
26. RPM Sensor installation _________________________________________________________________________ 29
27. EDM-900/930 Specifications and Limitations _________________________________________________________ 31
28. EMI Radio Test and functional check:_______________________________________________________________ 32
29. Component Parts _______________________________________________________________________________ 33
30. Weight and Balance Data ________________________________________________________________________ 35
31. Pilot Programming _____________________________________________________________________________ 35
32. Programming the HP Constant ____________________________________________________________________ 36
33. Programming the MAP __________________________________________________________________________ 36
34. Selecting Fuel Pressure Type (EDM-900 only) ________________________________________________________ 36
35. Customizing Non Primary Data (EDM900 only)- ______________________________________________________ 37
36. K Factor ______________________________________________________________________________________ 37
37. Fine tuning the K Factor _________________________________________________________________________ 38
38. Adjusting the K Factor___________________________________________________________________________ 39
39. Programming Accumulate Trip Total _______________________________________________________________ 39
40. Trouble Shooting _______________________________________________________________________________ 40
41. GPS Interface Diagnostics _______________________________________________________________________ 41
42. _______________________________________________ 42 Connector Pin Assignments on EDM, J1 through J5
43. Connector Pin Assignments on EDM, J1 through J5 ___________________________________________________ 43
44. J3 RPM, MP, Oil-P _____________________________________________________________________________ 46
45. Appendix A onnector Pin Assignments on EDM, J1 J2 Only with ARINC 429C- _____________________________ 50
46. Appendix B ICA _______________________________________________________________________________ 51
The Owner of the EDM-900/930 must keep this manual
J.P. INSTRUMENTS
PO BOX 7033
HUNTINGTON BEACH CA
Last printed 5/1/2017 3:28:00 PM
FAA Approved Installation Manual for the Report No 908
EDM-900 and EDM- 930 Page 2 of K 52 Rev
Primary Engine Data Management System Date 5-02-17
1. Revisions
REV
Description
Date
Approval
G
Added new pictures of 900 and 930, page 6. Abbreviations page 4. Revised how the
JPI data base functions Added revision box. Page 2. Added fuel level , page 3.
calibration, page 22. Renumbered all pages.
9- - 28 2011
JFP
H
Revised to include new trouble shooting section for ICA and renumber pages. Updated
pressure sensors to i2s
12 02 2011- -
JFP
I
Revised TSO Label to show lighting change and added ARINC 429 wire chart
1- - 18 2013
JFP
J
Updated Part Numbers and Added new ICA and Pressure bulkhead paragraph
5- - 24 2014
JFP
K
Updated for new features adding digital fuel gauges with fuel flow monitoring per the
“Flight manual”
4- - 08 2016
JFP
2. Read This First
The following notes apply to a new installation. Read this section before proceeding.
The JPI warranty found in the back of the pilots guide clearly states that JPI will replace defective parts under
warranty, but does NOT cover labor to remove or install any parts.
The most common cause of probe problems is poor terminal crimps. Crimp ring terminals with AMP tool or
equivalent. Fold back the wire double before crimping terminals.
- - Do not use aluminum fittings or Teflon tape or pipe sealant with the FXT 201 or FXT 231 fuel flow transducer.
-Write down the K factor engraved on the side of the fuel flow transducer here _______. Once the transducer is
installed and covered with the fire sleeve, you will not be able to access this K factor.
Determine the locations of all holes before drilling to ensure that nothing interferes with the probe, clamp, clamp
screw or wire.
Provide service loops at the instrument so that it can be moved for maintenance or troubleshooting.
Thermocouple wire length is not critical. Trim to required length, allowing for service loops at the engine so that
probes can be swapped with probes on adjacent cylinders for troubleshooting purposes.
Dress all wires away from high temperature components such as exhaust stacks.
-Never splice thermocouple wire using copper wire. Use only K type thermocouple wire. Solder using zinc
chloride flux such as Nokorode brand rosin flux alone will not work.
Observe correct polarity on all probe wires. Connect like colors together (red to red, yellow to yellow).
The instrument must be grounded at the engine, not at the avionics ground.
- - Record the installation of the EDM 900 or EDM 930 on a FAA form 337. Make an entry in the aircraft logbook.
Note: Removal of probes, sensors and the instrument is the reverse of the installation procedure.


Produkt Specifikationer

Mærke: J.P. Instruments
Kategori: Ikke kategoriseret
Model: EDM-930

Har du brug for hjælp?

Hvis du har brug for hjælp til J.P. Instruments EDM-930 stil et spørgsmål nedenfor, og andre brugere vil svare dig