Relay switch insert 2-channel
Light Management
Relay switch insert 2-channel
Art.-No.: 1202 URE
Operationsmanual
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Failure to observe the instructions may cause damage to the device and result in fire and
other hazards.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. At the same time, take into account all circuit breakers that supply dangerous
voltage to the device or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage.
Danger of electric shock on the SELV/PELV installation. Not suitable for switching SELV/
PELV voltages.
Danger of electric shock. Do not operate the insert without a cover.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
picture 1
(1) Flush-mounted insert
(2) Frame
(3) Pushbutton cover
(4) Adjuster for run-on time of output HLK
(5) Connection terminals for mains voltage and output Kanal 1
(6) Connection terminals for output for HVAC HLK
3 Function
Intended use
- Output for switching light Kanal 1
- Output for switching light, fans, air conditioners, thermostats and motors HLK
1/6
32541323
J:0082541323 30.07.2010
- Operation with suitable cover
- Installation in appliance box to DIN 49073 acc.
Product characteristics
- Output with potential-free NO contact for switching a second electric circuit, not SELV HLK
or PELV
- Switch-on delay of output can be switched off HLK
- Run-on time of output adjustable HLK
- Connection of extensions possible
Function with motion detector or presence detector cover
Output Kanal 1
- Output is switched on if motions are detected and the brightness is below the threshold set
on the cover.
- Output remains switched on as long as motions are detected.
- Output is switched off if no more motions are detected and the run-on time set on the cover
has elapsed.
Output HLK
- Switch-on delay switched on: output is switched on independently of the brightness after
3 minutes if additional motions are detected approx. 2.5 to 3 minutes after the initial
detection.
- Switch-on delay switched off: output is switched on independently of brightness if motion is
detected.
- Output remains switched on as long as motions are detected.
- Output is switched off if no more motions are detected and the run-on time set on the insert
has elapsed.
Behaviour after a mains voltage failure
- Less than 0.2 seconds: switching state is retained
- longer than 0.2 seconds: both channels switch off. The behaviour after mains voltage
return depends on the cover used (see instructions for the cover).
4 Operation
Switching on with pushbutton cover (see Accessories)
Operation on the main device, 2-wire extension or on the installation button is identical.
i Extension operation is only possible if there is a cover fitted on the main device.
Outputs are switched off.
o Press the button.
Output switches on. Kanal 1
When the switch-on delay for output is switched off, output switches on directly. HLK HLK
When the switch-on delay for output is switched on, output switches on with a HLK HLK
time delay, if output is switched on for longer than 3 minutes. Kanal 1
Switching off with pushbutton cover (see Accessories)
Outputs are switched on.
o Press the button.
Output switches off. Kanal 1
Output switches off after the run-on time set on the insert elapses. The run-on time HLK
begins as soon as output has switched off. Kanal 1
Switching on in combination with motion detector or presence detector
Operation is performed with a 2-wire extension or an installation button. Only an overview of the
behaviour is provided here. For additional information, please refer to the instructions for the
cover in question. Operation with an extension is only possible is there is a cover fitted on the
main device.
Outputs are switched off.
2/6
32541323
J:0082541323 30.07.2010
Light Management
Relay switch insert 2-channel


Produkt Specifikationer

Mærke: JUNG
Kategori: Skifte
Model: 1202URE

Har du brug for hjælp?

Hvis du har brug for hjælp til JUNG 1202URE stil et spørgsmål nedenfor, og andre brugere vil svare dig




Skifte JUNG Manualer

JUNG

JUNG W8180 Manual

10 December 2024
JUNG

JUNG 201TE Manual

10 December 2024
JUNG

JUNG ASLS1280-1 Manual

20 September 2024
JUNG

JUNG ME5201DTU Manual

2 September 2024
JUNG

JUNG SL1180 Manual

28 August 2024
JUNG

JUNG AS5544.03VWW Manual

28 August 2024
JUNG

JUNG ES5201DTU Manual

28 August 2024
JUNG

JUNG SL1180-1 Manual

28 August 2024
JUNG

JUNG CD5024WW Manual

28 August 2024
JUNG

JUNG A1180-1 Manual

23 August 2024

Skifte Manualer

Nyeste Skifte Manualer