Læs gratis den danske manual til Kathrein ESO 124 H (4 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 25 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 13 anmeldelser. Har du et spørgsmål om Kathrein ESO 124 H, eller vil du spørge andre brugere om produktet?

Side 1/4
1 / 4
ESO 90 H 237500001
ESO 120 H 237500002
ESO 124 H 237500003
ESO 124 HL 237500005
Reflector Heating System for CAS 90, CAS 120 and CAS 124
Features
Flexible special heating mat with integrated thermal insulation
and PTFE-insulated heating elements
Good heat distribution due to an optimal fit of the heating mat
on the reflector
Element carrier of aluminium foil, self-adhesive foil strips at
the front
Thermal insulation made of bubble wrap with reflective layer,
4 mm
Built-in sensor to additionally define the heating temperature
via a control
About These Instructions
This document is part of the product. These instructions
describe how to install and connect the reflector heating
systems ESO 90 H, ESO 120 H, ESO 124 H and ESO 124 HL.
Do not install or use the device until you have read and
understood this document.
Keep this document for reference throughout the service life
of the device. Pass this document on to any new owner or
user.
The current version of this document can be found at
www.kathrein-ds.com
Scope of Supply
1 x heating mat with 3 m cable (H05RNF) and heating tempe-
rature sensor
Mesh reinforced aluminium foil, 0.05 x 5 m
Adhesive film (white) for covering the aluminium foil,
0.075 x 5 m
5 x cable ties, 360 mm
Transport and Storage
If possible, transport and store the heating mat in its original packaging.
Protect the heating mat against moisture and mechanical damage.
Transport and store the heating mat only in the permitted temperature range between -40 and +80°C. Make sure there is no
condensation build-up.
Functional Description
The electric heating system prevents snow and ice formation on the antenna reflector surface which may lead to interruptions in
satellite reception. The heating for the antenna consists of a special heating mat with an integrated thermal insulation and PTFE-insu-
lated heating elements. The installed heating mat fits optimally on the reflector and guarantees good heat distribution. The heating
mat has an integrated temperature switch that turns o the heating at 80°C so that the system can be operated at 230 V/50Hz. To
ensure ecient operation, we recommend the use of a control unit, which can be operated with or without the built-in sensor.
Possible system components:
Operation without temperature
sensor
Operation with temperature sensor Operation without control possible
ESO 90/120/124 H ESO 005, ESO 96, ESO 97 ESO 97 SL Yes
ESO 124 HL - ESO 99 + ESO 101, ESO 97 SL No
ESO 90 H
1 x heating mat with 3 m cable (H05RNF) and heating tempe-
rature sensor
Mesh reinforced aluminium foil, 0.05 x 8 m
Adhesive film (white) for covering the aluminium foil,
0.075 x 8 m
5 segments (ESO 120 H) or 4 segments (ESO 124 H/HL) of
white adhesive foil for covering the outer contours of the
heating mats
5 x cable ties, 360 mm
ESO 120 H, ESO 124 H, ESO 124 HL
ESO 90 H ESO 120 H
ESO 124 H/HL
ESO 124 HL:
For exposed locations, with
double the heating power
compared to ESO 124 H
(L = increased performance).
2 / 4
DANGER!
Danger to life from electric shock when touching electrical installations!
Disconnect all devices and units from the power supply during installation.
In order to comply with the regulations for outdoor installation according to DIN VDE 0100 Part 610, it is recom-
mended to have a residual current circuit breaker with a residual current of 0.03 A installed.
Make sure that installation and connection are only carried out by qualified personnel.
Make sure that modifications to electrical installations are only carried out by a specialist. Do not make any unautho-
rised changes yourself.
Installation and Safety Instructions
WARNING!
Risk of severe injuries during installation due to falling from or through the roof or falling parts!
Wear sturdy shoes with non-slip soles.
Use a working platform.
Make sure that the person carrying out the installation or repair has a secure position to stand and hold on whilst
working.
Make sure that the person carrying out the installation or repair does not suer from vertigo and can move around
safely on the roof or installation site.
Make sure that the vehicle roof is suciently strong and stable.
Make sure that there is nobody underneath the antenna during installation/dismantling.
Installing the Reflector Heating
Required tools and equipment
Knife
Scissors
Installing the heating mat
Processing temperature
The most favourable processing temperatures (object temperature and ambient temperature) are between +15°C and +30°C. Proces-
sing below these temperatures is not recommended. Below the recommended temperatures, the adhesive may become too hard and
thus not achieve the desired adhesion.
The build-up of condensation must be avoided in any case. Condensation may build up when the adhesive tape and/or the surfaces
to be bonded are moved from a cold to a warmer environment. If this is the case, sucient time must be allowed after transport and
before bonding, so that all joining parts have the same temperature in the range indicated above.
Intended Use
The ESO 90 H, ESO 120 H, ESO 124 H and ESO 124 HL are reflector heating systems for the antennas CAS 90, CAS 120 and CAS 124.
They are used to prevent snow and ice formation on the antenna reflector surface which could lead to interruptions in the satellite
reception. Any other use, or failure to comply with these instructions or documentation and instructions enclosed with the devices,
will result in voiding of warranty or guarantee. The following circumstances result in the loss of all warranty and liability claims
towards the manufacturer:
Improper installation
Use of non-specified mounting materials, which cannot guarantee the mechanical reliability of the antenna system
Structural changes or interference with the components and mounting accessories in the kit, which could endanger both the
mechanical and functional reliability
Failure to observe installation and safety instructions in these instructions
1. Clean and degrease the antenna back panel.
The surface to be bonded must always be dry, free from dust, grease, oil, oxides, separating agents and other contaminants.
Isopropanol, ethanol, acetone, ethyl acetate, toluene or petrol can be used to remove dust, grease, oil, separating agents and
other contaminants. Other standard cleaning agents that do not leave any residues are also suitable. Please observe the respec-
tive safety regulations of the manufacturers of the solvents and cleaning agents.


Produkt Specifikationer

Mærke: Kathrein
Kategori: Ikke kategoriseret
Model: ESO 124 H

Har du brug for hjælp?

Hvis du har brug for hjælp til Kathrein ESO 124 H stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Kathrein Manualer

Kathrein

Kathrein UFX 12 Manual

5 Februar 2025
Kathrein

Kathrein UFX 14 Manual

5 Februar 2025
Kathrein

Kathrein FMK 100b Manual

15 Januar 2025
Kathrein

Kathrein UFO 83 Manual

28 September 2024
Kathrein

Kathrein UFO 80 Manual

19 September 2024
Kathrein

Kathrein ZAS 41XS Manual

10 September 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer