Photo studio
1. Test button
2. Photocell
3. ‘Ready’ indicator
4. Mains ON/OFF
5. Fuse
6. Modeling lamp switch ON/OFF
7. Sync cord
8. Flash power control
Flash Energy 150 W
Typical recycle time 2 Seconds
Stepless flash power control Full to 1/8
Recommended modeling lamp E14 bulb 75 W
Flash colour temperature Approx. 5500 K
Flash trigger Light, sync cord, manual infrared, radio.
Trigger voltage 12 V
Operating voltage 180-230 V
Output precision Within 1%
Operation:
Switch the unit ON and set the “Flash power control” and “Modeling lamp switch” as required. When the unit
has charged to the required level, the red “Ready” indicator will light. The “Test button” should be pressed to
ensure that the flash is of the required power. Plug in the “Sync cord” and connect to the camera shutter at “X”
synchronization. Alternatively, use the built-in “Photocell” or plug in the “Radio remote control receiver”.
Power supply connections
220 V AC 50 Hz. Use the main lead supplied to connect to the main supply.
Main ON/OFF switch
Set the red illuminated On/Off switch to “ ” to turn the unit ON.
Flash power selection
The unit can offer stepless power variation from full to 1/8, rotate the power control to adjust the power you
need.
Charge
When first switched to “ ”, the red illuminated ON/OFF switch will light up. When the unit has charged to the
level set by the flash power selector, the red “Ready” Indicator will light up again. Your flash light is now ready.
1 2 3
4
5
6
7
8