Model 8112 Instruction Manual
1. Safety precautions
This instrument has been designed and tested according to IEC Publication 61010:
Safety Requirements for Electronic Measuring Apparatus. This instruction manual
contains warnings and safety rules which must be observed by the user to ensure safe
operating instructions before starting to e the instrument. us
The symbol indicated on the instrument means that the user must refer to the
related part in the manual for safe operation of the instrument. Be sure to carefully read
the instructions following each symbol in this m a anu l.
Measurement categories(Over-voltage categories)
To ensure safe operation of measuring instruments, IEC 61010 establishes safety
standards for various electrical environments, categorized as CAT O to CAT IV and
called measurement categories.
Higher-numbered categories correspond to electrical environments with greater
momentary energy, so a measuring instrument designed for CAT III environments can
endure greater momentary energy than one designed for CAT II.
CAT Primary electrical circuits of equipment connected to an AC electrical outlet by II :
a power cord.
2. Features
MODEL 8112 is a clamp type AC current / voltage conversion probe which can
measure 0.1 mA to 120 A AC by connecting and using with a digital ltimeter. mu
It is simple to operate, measurement range is selectable among mA, 2 A, and 200 and
20 A .
3. Specications
Range
switch
position
Measuring
range
Output
Accuracy
Frequency
Range
200mA /
200mV
(1mA / mV)
0 to 500 mA AC
0 to 500 mV AC
±1.5%rdg ±0.2 mA
50 Hz to 1 kHz
0 to 1000 mA AC
0 to 1000 mV AC
±3.0%rdg ±0.4 mA
40 Hz to 10 kHz
2A / 200mV
(10mA / mV)
0 to 20 A AC
0 to 2000 mV AC
±1.0%rdg ±1 mA
40 Hz to 1 kHz
±1.5%rdg ±2 mA
1 kHz to 10 kHz
20A / 200mV
(100mA /
mV)
0 to 20 A AC
0 to 200 mV AC
±1.0%rdg ±0.01 A
40 Hz to 1 kHz
20 to 60 A AC
200 mV to 600 mV AC
±2.5%rdg
50 Hz to 10 kHz
60 to 120 A AC
600 mV to 1200 mV AC
±2.5%rdg
100 Hz to 10 kHz
Frequency characteristics : Within ±3dB at 30 Hz to 100 kHz
Output impedance : Approx. 2 k Ω
Guaranteed temperature : ºC±5ºC, relative humidity or less (no condensation) 23 85%
and humidity range
Operating temperature - ºC to 50ºC, relative humidity 85% or less (no condensation) : 10
and humidity range
Storage temperature - ºC to ºC, relative humidity 80% or less (no condensation) and : 20 60
humidity range
Location for use : Indoor use, Altitude up to 2000m
Complied standards IEC 61010-1 CAT II 100V, Pollution degree 2, IEC 61010-2- : 32
Environmental standard : EU RoHS directive compliant
Withstand voltage V : 500 AC/ 1 min etween electrical circuit and enclosure) . (b
Insulation resistance V etween electrical circuit and : 10MΩ or greater at 500 DC (b
enclosure)
Conductor size : Approx. 8 (max.) mm
Output cord : Insulated ield wire (3.9 in diametersh mm , approx. 1.5 m
long, and ana plug with barrier) ban
Dimension and weight mm(W) x 152.5 mm(L) x 23 mm(D) : 18
Approx. 100 g (including output cord)
Accessories : Carrying case MODEL 9095 and instruction manual
4. Instruction layout
Jaw Current detection CT
Barrier Provid protection against electrical shock and ensures the es
minimum required air and creepage distances.
Slide switch O s and closes pen Jaw.
Range switch Selects measurement range.
Banana plug To be connected to a digital multimeter.
Polarity mark Indicates the direction of current to display positive value on a
connected multimeter: when current ows along the direction of is th
mark, the output will be positive.
5. Operating instructions
(1) Connect Banana plug with barrier to a digital multimeter (range on the multimeter
should be ACV ).
(2) Sli Slide switch to open Jaw to clamp the de
conductor to be measured.
(3) When current ows along the direction of the polarity
mark on Jaw, measured value displayed on
the multimeter will be positive value.
(4) Slide Range switch to select an appropriate range
depending on the current magnitude owing through
the conductor.
(5) How to read current value:
Output voltages are as follows.
- When measuring 200 mA on 2 mA range of M-8112, 00
the multimeter indicates 200 mV.
- When measuring 2 A on 2A range of M-8112, the multimeter
indicates 200 mV.
- When measuring 20 A on 20A range of M-8112, the multimeter
indicates 200 mV.
The followings are the examples of how to take r dings. ea
- When 500 mA is measured by M-8112 setting to 200mA range, the connected
multimeter setting to 2V ra reads 0 V. nge .500
- When 10 A is measured by M-8112 setting to 2A range, the connected multimeter
setting to 2V ra reads 1.000 V. nge
- When 60 A is measured by M-8112 setting to A range, the connected multimeter 20
reads 0.6 V. 00
8-22 92-1807C
Kyoritsu reserves the rights to change specifications or designs described in this
manual without notice and without obligations.
WARNING
Read through and understand instructions contained in this manual before starting
to the instrument. use
Save and keep the manual at to enable quick reference whenever necessary. hand
The instrument is to be used only in its intended applications.
Understand and follow all the safety instructions contained in the manual.
Failure to follow the instructions may cause injury, instrument damage and/or
damage to the equipment under test. Kyoritsu is by no means liable for any damage
resulting from the instrument in contradiction to these cautionary notes.
DANGER : is reserved for conditions and actions that are likely to cause serious or
fatal injury.
WARNING : is reserved for condition and actions that can cause serious or fatal s
injury.
CAUTION : is reserved for conditions and actions that can cause minor injury or
instrument damage.
DANGER
Never make measurement on a circuit above 100 V AC (CAT II).
Do not attempt to make measurement i a presence of ammable gasses, fumes, n
vapor or dust. Otherwise, use of the instrument may cause sparking, which can
lead to an explosion.
Never attempt to use the instrument if its surface or your hand is wet.
Never attempt to make any measureme the instrument has any mechanical nt if
abnormality such as cracked case or damaged output cable metal part.
The instrument should be used only in its intended applications or conditions;
otherwise, safety features provided by the instrument don t work, and instrument
damage or serious personal injury may be caused.
Keep your ngers and hands behind the barrier during measurement.
WARNING
Do not install substitute parts or make any modification to the instrument. Return the
instrument to Kyoritsu or ur local KYORITSU distributor for repair or re-calibration. yo
CAUTION
M sure that the range switch is set to an appropriate position before making ake
measurement.
Do not expose the instrument to direct s light, extreme temperature, or dew fall. un
Use a damp cloth and detergent for cleaning the instrument. Do not use abrasives or
solvents.
J aw
Barrier
Slide switch
Range switch
Banana plug
Polarity mark


Produkt Specifikationer

Mærke: Kyoritsu
Kategori: Måling
Model: 8112

Har du brug for hjælp?

Hvis du har brug for hjælp til Kyoritsu 8112 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Måling Kyoritsu Manualer

Kyoritsu

Kyoritsu KEW3128 Manual

3 August 2025
Kyoritsu

Kyoritsu KEW3123A Manual

3 August 2025
Kyoritsu

Kyoritsu KEW 8122 Manual

3 August 2025
Kyoritsu

Kyoritsu 8125 Manual

2 August 2025
Kyoritsu

Kyoritsu KEW 8135 Manual

2 August 2025
Kyoritsu

Kyoritsu 3005A Manual

2 August 2025
Kyoritsu

Kyoritsu 8127 Manual

2 August 2025
Kyoritsu

Kyoritsu 3165 Manual

2 August 2025
Kyoritsu

Kyoritsu KEW 8161 Manual

2 August 2025

Måling Manualer

Nyeste Måling Manualer

Sauermann

Sauermann VT 110 Manual

13 August 2025
Sauermann

Sauermann GP 500-2 Manual

13 August 2025
Sauermann

Sauermann HD 50 Manual

13 August 2025
Sauermann

Sauermann Si-VV3 Manual

13 August 2025
Sauermann

Sauermann MP 112 Manual

13 August 2025
Sauermann

Sauermann MP 115 Manual

13 August 2025
Sauermann

Sauermann KH 120 Manual

13 August 2025
Sauermann

Sauermann DBM 620 Manual

13 August 2025
Sauermann

Sauermann AQ 110 Manual

13 August 2025