Kyoritsu KEW 8031 Manual

Kyoritsu Måling KEW 8031

Læs gratis den danske manual til Kyoritsu KEW 8031 (2 sider) i kategorien Måling. Denne vejledning er vurderet som hjælpsom af 4 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 2.5 anmeldelser. Har du et spørgsmål om Kyoritsu KEW 8031, eller vil du spørge andre brugere om produktet?

Side 1/2
1. Safety Warnings
This instrument has been designed and tested according to IEC
Publication 61010: Safety Requirements for Electronic Measuring
Apparatus. This instruction manual contains warnings and safety
rules which must be observed by the user to ensure safe operation of
the instrument and retain it in safe condition. Therefore, read through
these operating instructions before starting using the instrument.
# WARNING
●Read through and understand instructions contained in this
●Save and keep themanual handyto enablequick reference
whenever necessary.
●Theinstrumentistobeusedonlyinitsintendedapplications.
●Understand and follow all the safety instructions contained in
the manual. Failure to follow the instructions may cause injury,
instrument damage and/or damage to equipment under test.
Kyoritsu is by no means liable for any damage resulting from
the instrument in contradiction to this cautionary note.
The symbol indicated on the instrument means that the user #
must refer to related parts in the manual for safe operation of the
instrument. Be sure to carefully read the instructions following
each symbol in this manual.
# DANGERisreservedforconditionsandactionsthatarelikely
to cause serious or fatal injury.
# WARNING is reserved for conditions and actions that can
cause serious or fatal injury.
# CAUTION is reserved for conditions and actions that can
cause minor injury or instrument damage.
Thefollowingsymbolsareusedandmarked on the instrument and
in the instruction manual. Please carefullycheckbeforestartingto
use the instrument.
#
Must refer to the Instruction Manual to protect humans and devices.
Instrument with double or reinforced insulation.
AC
Thisinstrumentsatisfies themarkingrequirement defined
in the WEEE Directive (2002/96/EC). This symbol indicates
separate collection for electrical and electronic equipment.
# DANGER
●Never make measurementon a circuitin which the earth
potentialexceeds600Vtoavoidelectricalshocks.
Do not makemeasurement when thunderis rumbling.Ifthe
instrument is in use, stop the measurement immediately and
remove the instrument from the measured object.
●Put insulated protectivegears when there isa danger of
electricalshockhazard.
●
Do not attempt to make measurement in thepresenceof
flammable gasses, fumes, vapor or dust. Otherwise, the use of the
instrumentmaycausesparking,whichcanleadtoanexplosion.
●
Neverattempttousetheinstrumentifitssurfaceoryourhandiswet.
●Theinstrumentshouldbeusedonlyinitsintendedapplications
or conditions. Otherwise, safety functions equipped with the
instrument do not work, and instrument damage or serious
personal injury may be caused.
# WARNING
●Neverattempttomakeanymeasurement,iftheinstrumenthas
anystructural abnormality suchas cracked caseand exposed
metal part.
●First,connecttheTestertoThree-phasesystemandthenpress
the push switch button.
●If thecables are accidentallydisconnected, release yourhand
from the push switch button and stop measurement.
●Dont touchthe disconnected cables while thepush switch
button is being pressed down.
●Stopusingthetestleadiftheouterjacketisdamagedand the
innermetalorcolorjacketisexposed.
●Do notinstall substitute parts ormake any modification tothe
instrument. Return the instrument to Kyoritsu or your distributor
forrepairorre-calibration.
INSTRUCTION MANUAL
PHASE INDICATOR
KEW 8031
1-22 92-2430
A tor C p setlliga li
RED
WHITE
BLUE
DISTRIBUTOR
Kyoritsu reserves the rights to change specifications or designs
described in this manual without notice and without obligations.
3. Specifications
Nominalsystem Un voltage AC230V
Voltage ranges AC110V to 600V
Rated frequency 50Hz/60Hz
Continuous operation time Continuous up to AC280V
40minutesorlessfromAC281VtoAC300V
20minutesorlessfromAC301VtoAC400V
10minutesorlessfromAC401VtoAC500V
5 minutes or less from AC501V to AC600V
Standards IEC60529(IP30)
Environmental standards IEC50581(EURoHS)
Location for use
Altitude 2000m or less, Indoor use
Withstand Voltage AC6300V(rms)for5seconds
Dimensions
106(L)x75(W)x40(D)mm(Body)
1.3m(Testlead)
Weight Approx.350g
Accessories Instruction manual
Carrying Case
4. Operating instructions
# WARNING
●First,connecttheTestertoThree-phasesystemandthenpress
the push switch button.
●Ifthecables are accidentallydisconnected, releaseyour hand
from the push switch button and stop measurement.
●Dont touchthedisconnected cables whilethepushswitch
button is being pressed down.
# CAUTION
●Evenifallmissingphaseindicatorsareoff,onephasemightbe
live:careshouldbetakentoavoidgettingelectricshock.
●Max continuous measurement time differs depending on
voltages. Please refer to continuous measurement time written
in this document and measure each voltage within each limited
time.
# CAUTION
●Evenifallmissingphaseindicatorsareoff,onephasemightbe
live:careshouldbetakentoavoidgettingelectricshock.
●Max continuous measurement time differs depending on
voltages. Please refer to continuous measurement time written
in this document and measure each voltage within each limited
time.
●Do not expose the instrument to the direct sun, extreme
temperatures or dew fall.
●Useadampclothanddetergentforcleaningtheinstrument.Do
not use abrasives or solvents.
●Thisinstrumentisn'tdust&waterproofed.Keepawayfromdust
and water.
●Choose anduse the testleads andcaps that are suitablefor
the measurement category. When the instrument and the test
lead are combined and used together, whichever lower category
either of them belongs to will be applied.
●Keepyourfingersandhandsbehindtheprotectivefingerguard
during measurement.
2. Features
●TwoFunctionsinOneUnit
KEW8031 is designed to check phase sequence. Lamps
provided on the unit will also tell you if a phase is open.
●HighlyReliable
Can check a wide range of 3-phase powersource from 110V
to 600V. Sealed against dust, the unit ensures trouble-free
performance.
●FunctionalDesign
Small, Lightweight and portable. Designed for maximum ease of
operation and ruggedness.
●Safety Design
No exposed metal parts. Safety features are incorporated
including the instant push button switch operation.
(1) Connect colour coded alligator clips or prods to the terminals
ofa3-phasepowersourcewherearotatingelectricalmachine
such as a motor will be connected or input to a building.
(2) Press the push switch button located on top of the unit. Keep
this button pressed during phase sequence or open phase
check.Whenthepushswitchbuttonisreleaseditimmediately
goes off.
(3)Makesurethatallofthethreelampsforphasecheckareon.If
so,thereisnoopenphase.WhenanyofthethreelampsisNot
on there is open phase.
Openphasecheck → Openphaseonterminal
Lamp "L1" is not on where Red alligator clip
is connected.
Openphasecheck → Openphaseonterminal
Lamp "L2" is not on where Whight alligator clip
is connected.
Openphasecheck → Openphaseonterminal
Lamp"L3"isnoton whereBluealligatorclip
is connected.
Whentheopenphasechecklampsarenotontherotatingdisc
does not turn.
(4)Checktherotating directionof the inside discthrough the
phase sequence indication window.
When the rotating disc turns counter-clockwise alternate the
connection of the two of the three alligator clips. Then, the
rotatingdiscwillturnclockwise.
WhentherotatingdiscturnsclockwisephasesequenceisL1,L2
andL3inorderof thepowersource terminalswhere theRed,
Whight and Blue alligator clips are connected.
Wiring diagram


Produkt Specifikationer

Mærke: Kyoritsu
Kategori: Måling
Model: KEW 8031

Har du brug for hjælp?

Hvis du har brug for hjælp til Kyoritsu KEW 8031 stil et spørgsmål nedenfor, og andre brugere vil svare dig