Læs gratis den danske manual til Liberty Pumps PRG101A (12 sider) i kategorien Pumpe. Denne vejledning er vurderet som hjælpsom af 27 personer og har en gennemsnitlig bedømmelse på 4.7 stjerner ud af 14 anmeldelser. Har du et spørgsmål om Liberty Pumps PRG101A, eller vil du spørge andre brugere om produktet?

Side 1/12
Installer: Manual must
remain with owner/operator.
Prior to installation, record information
from pump nameplate for future reference:
Model:
7000 Apple Tree Avenue
Bergen, NY 14416
ph: 800-543-2550
fax: 585-494-1839
www.LibertyPumps.com
Keep this manual handy for future reference.
For replacement manual, visit LibertyPumps.com,
or contact Liberty Pumps at 800-543-2550.
Retain dated sales receipt for warranty.
Serial:
Mfg Date:
Install Date:
Installation Manual 2399000D
Copyright © Liberty Pumps, Inc. 2020
All rights reserved.
ProVore® 1 HP Residential Grinder Pumps
PRG-Series
Models
PRG101-Series
115 Volts
PRG102-Series
230 Volts
2 | EN Copyright © Liberty Pumps, Inc. 2020
All rights reserved. 2399000D
Contents
Safety Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 | EN
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . 4 | EN
Operating Constraints . . . . . . . . . . . . . . . . . . . . . . . . . 4 | EN
Inspection and Storage . . . . . . . . . . . . . . . . . . . . . . . . . 4 | EN
Model Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 | EN
Pump Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 | EN
Pump System Components . . . . . . . . . . . . . . . . . . . . . 5 | EN
Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 | EN
Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 | EN
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 | EN
Maintenance and Troubleshooting . . . . . . . . . . . . . . . 9 | EN
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 | EN
Safety Guidelines
Safety Precautions
Accidental contact with electrically live parts, items, fluid, or
water can cause serious injury or death.
Always disconnect pump(s) from power source(s) before
handling or making any adjustments to either the pump(s),
the pump system, or the control panel.
All installation and maintenance of pumps, controls,
protection devices, and general wiring shall be done by
qualified personnel.
All electrical and safety practices shall be in accordance with
the National Electrical Code®, the Occupational Safety and
Health Administration, or applicable local codes and
ordinances.
Do not remove cord and strain relief, and do not connect
conduit to pump.
Pump shall be properly grounded using its supplied
grounding conductor. Do not bypass grounding wires or
remove ground prong from attachment plugs. Failure to
properly ground the pump system can cause all metal
portions of the pump and its surroundings to become
energized.
Do not handle or unplug the pump with wet hands, when
standing on damp surface, or in water unless wearing
Personal Protective Equipment.
Always wear dielectric rubber boots and other applicable
Personal Protective Equipment (PPE) when water is on the
floor and an energized pump system must be serviced, as
submerged electrical connections can energize the water. Do
not enter the water if the water level is higher than the PPE
protection or if the PPE is not watertight.
Do not lift or carry a pump or a float assembly by its power
cord. This will damage the power cord, and could expose the
electrically live wires inside the power cord.
The electrical power supply shall be located within the length
limitations of the pump power cord, and for below grade
installations it shall be at least 4 ft (1.22 m) above floor level.
Do not use this product in applications where human contact
with the pumped fluid is common (such as swimming pools,
fountains, marine areas, etc.).
Protect the power and control cords from the environment.
Unprotected power and control (switch) cords can allow water
to wick through ends into pump or switch housings, causing
surroundings to become energized.
Single-phase 208/230V pumps shall only be operated without
the float switch by using the circuit breaker or panel
disconnect.
Some products may have internal capacitors that could cause
shock. Avoid contact with plug ends after removing from
energy source.
Do not use metal or any other electrical conducting material
to raise the float or contact anything inside an electrically live
sump pit.
This safety alert symbol is used in the manual
and on the pump to alert of potential risk for
serious injury or death.
This safety alert symbol identifies risk of
electric shock. It is accompanied with an
instruction intended to minimize potential
risk of electric shock.
This safety alert symbol identifies risk of fire.
It is accompanied with an instruction
intended to minimize potential risk of fire.
This safety alert symbol identifies risk of
serious injury or death. It is accompanied
with an instruction intended to minimize
potential risk of injury or death.
Warns of hazards which, if not avoided, will
result in serious injury or death.
Warns of hazards which, if not avoided, could
result in serious injury or death.
Warns of hazards which, if not avoided, could
result in minor or moderate injury.
Signals an important instruction related to
the pump. Failure to follow these instructions
could result in pump failure or property
damage.
Read every supplied manual before using
pump system. Follow all the safety instructions
in manual(s) and on the pump. Failure to do
so could result in serious injury or death.
RISK OF ELECTRIC SHOCK