Læs gratis den danske manual til Noritz EZ2FVK-1 (24 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 18 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 9.5 anmeldelser. Har du et spørgsmål om Noritz EZ2FVK-1, eller vil du spørge andre brugere om produktet?

Side 1/24
1
Installation Manual NORITZ AMERICA
CORPORATION
Potential dangers from accidents during installation and use are divided into the following three categories.
Closely observe these warnings, they are critical to your safety.
DANGER indicates an imminently hazardous situation which, if not avoided,
will result in death or serious injury.
WARNING indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury.
CAUTION indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury.
Installation must conform with local codes, or in the absence of local codes, the National Fuel Gas Code, ANSI Z223.1
/NFPA54-latest edition.
Noritz America reserves the right to discontinue, or change at any time, the designs and/or specifications of its
products without notice.
DANGER
Never use this Vent Kit other than for the Applicable Model (including the model manufactured by others)
designated in this manual.
WARNING
If the information in this manual is not followed exactly, a fire or explosion may result causing property
damage, personal injury or death.
Do not install only with the EZTR Start-up Guide. Read this manual also before installation.
Requests to Installers
This manual is for the vent components for the designated tankless water heater. For the installation
of the Tankless Water Heater itself, read the installation manual packed with it.
In order to install this vent kit correctly, read this installation manual carefully, and follow the installation instructions.
Failures and damage caused by erroneous work or work not as instructed in this manual are not covered by the warranty.
Check that the installation was done properly in accordance with this installation manual upon completion.
After completing installation, place this installation manual in a plastic pouch and attach it to the side of the
water heater, or hand it to the customer to retain for future reference.
Vent Kit for Condensing Tankless Gas Water Heater
EZ2FVK-1-LT
Rev. 01/17
SBB80TX
[Applicable Model]
[EZTR40] NRC663-FSV
[EZTR50] EZ98DV (GQ-C2859WX-FF US)
[EZTR75] EZ111DV (GQ-C3259WX-FF US)
Model: EZ2FVK-1
(Flex Vent 2" Kit 25 feet)
DANGER
WARNING
CAUTION
CAUTION
Prohibited Be sure to do
2
1.General Information
Property damage, personal injury or death can result if these instructions are not followed. They are a guide for
professional installers generally familiar with the installation and maintenance of heating equipment and related vent
systems.
Flex Vent 2" Kit is designed only for the installation inside of B-Vent as sleeve.
Do not use it for other installation method. Also do not use it outdoor.
Do not use for anything other than designated Tankless Water Heater (including the model manufactured by
others).
Flex Vent 2" Kit can be installed at zero clearance to combustible materials.
Appliances can be started up immediately after Flex Vent 2" Kit is installed and inspected.
Flex Vent 2" Kit vent systems expand and contract slightly during heating cycles and
must be installed following included instructions.
 ℃ Keep Flex vent greater than 40 F(5 ) during installation.
Damage will occur if handled or installed at lower temperatures.
Information regarding certification of "Flexible vent pipe and connections".
Standard(s) ULC-S636-08 Standards for type BH Gas Venting Systems
Product
25Feet-Flex Pipe 2"-LE , Flex Vent 2" Rigid 45 Elbow Set - LE
Brand name Living Engineering Co., Ltd.
40°F