MODEL: CP024
AC/DC CLAMP CURRENT PROBE
1
INTRODUCTION
The is a mini size clamp current probe. It can convert the test current into a
voltage output. As an adapter of the oscilloscope, it is very convenient to use
this probe to test AC or DC current in any conductor.All ranges are selected by
toggle switch, easy to operate.It is an ideal tester for maintenance and
inspection work on all types of electrical equipment.
2
SAFETY INTRODUCTIONS
Please according to the method of using this manual before operating
equipment, in case the instrument damage.
To maintain the instrument use safety, please do not test beyond the
prescribed current.
Do not use a broken probe signal output line.
When testing working voltage higher than 60 VDC or 30 vac line, please be
careful to use.
Operating environment condition:
1. Secondary safety insulation
2. Secondary pollution
3. Suitable for indoor use
4. Relative humidity below 70%RH
5. Operating temperature: 0C to 40C
Maintenance Essentials:The inspection and maintenance detailed in this
manual shall be handled by professionally qualified maintenance personnel.
Essentials of cleaning:Clean with dry cloth, do not use stain remover, solvent
clean this probe.
Safety symbols description:
Caution, risk of danger (refer to this manual for
specific Warning or Caution information)
Equipment protected throughout by double
insulation or reinforced insulation
Conforms to European Union directives
3
Specification
3.1 GENERAL Specification
RANGE
4A40A400A
Minimum resolution
10mA
Band wide up to 200KHz-3dB
Error by earth magnetic: ± 30mA max
Remanence(±100A
0A)
± 30mA max
Jaw size: 23mm (Max)
Auto Zero at power on
Low battery/return to zero indicator: When the battery voltage is lower
than the operating voltage, the indicator lights up; When press
the return to zero key, the output automatically return to zero, at
the same time the indicator light on, after the end of the return to
zero yellow and green indicator light automatically out.
Power Supply: 9V 6F22 Battery
Power Consumption:280mW (typical)
Operating temperature and humidity:
0C to 40C ,relative humidity below 70%RH
Store temperature and humidity:
-10C to 60C ,relative humidity below 70%RH
Size: 180mm(L)x 44mm(W)x 30mm(H)
Weight: Approx. 200g
Accessories: Manual,Battery
3.2ELECTRICAL SPECIFICATIONS
Accuracy are (%rdg + Number of current) at 23C5C below 70%RH;
DC CURRENT:
Range
Accuracy
Sensitivity
4A
±1.5%rdg±5d
1 mV/10 m A
40A
±1.5%rdg±5d
1 mV/ 0.1A
300A
±1.5%rdg±5d
1 mV/ 1A
300A~400A
±3.5%rdg±5d
1 mV/ 1A
AC CURRENT:


Produkt Specifikationer

Mærke: Owon
Kategori: Måleudstyr
Model: CP024

Har du brug for hjælp?

Hvis du har brug for hjælp til Owon CP024 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Måleudstyr Owon Manualer

Owon

Owon ORF5060 Manual

5 September 2024
Owon

Owon HSA015 Manual

5 September 2024
Owon

Owon HSA1016 Manual

2 September 2024
Owon

Owon DGE3000 Manual

2 September 2024
Owon

Owon CP024 Manual

2 September 2024
Owon

Owon XDS3000 Manual

2 September 2024
Owon

Owon HDS200 Manual

2 September 2024
Owon

Owon AS201 Manual

2 September 2024
Owon

Owon SDS1102 Manual

1 September 2024
Owon

Owon XDM1241 Manual

1 September 2024

Måleudstyr Manualer

Nyeste Måleudstyr Manualer

Uni-T

Uni-T UT220 Manual

3 April 2025
Uni-T

Uni-T UT681C Manual

3 April 2025
Uni-T

Uni-T UT216C Manual

3 April 2025
Uni-T

Uni-T UT611 Manual

3 April 2025
Uni-T

Uni-T UT210D Manual

3 April 2025
Uni-T

Uni-T UT210C Manual

3 April 2025
Uni-T

Uni-T UT210B Manual

3 April 2025
Uni-T

Uni-T UT682 Manual

3 April 2025
Uni-T

Uni-T UT275 Manual

3 April 2025
Uni-T

Uni-T UT08A Manual

3 April 2025