Paxton Touchlock K38 Manual


Læs gratis den danske manual til Paxton Touchlock K38 (4 sider) i kategorien Sikkerhed adgangskontrolsystem. Denne vejledning er vurderet som hjælpsom af 20 personer og har en gennemsnitlig bedømmelse på 4.2 stjerner ud af 10.5 anmeldelser. Har du et spørgsmål om Paxton Touchlock K38, eller vil du spørge andre brugere om produktet?

Side 1/4
Ins-30077 - TOUCHLOCK K and KP series
Fitting
28/11/2011
Technical Support
Technical help is available: Monday - Friday from 07:00 - 19:00 (GMT)
Saturday from 09:00 - 13:00 (GMT)
01273 811011 support@paxton.co.uk
K75 Screw connector option
The unit should be mounted in conjunction with
an electrical backbox to achieve the required
clearance for the connector.
If an adaptor plate (310-750) is tted, the
mountings on the backbox can also be used.
Documentation on all Paxton products can be found on our website - http://www.paxton.co.uk/
Cable extensions
Readers can be extended using Belden CR9540 10-core overall screened cable to a maximum of 100 metres.
Illustrations in this instruction show the standard keypad.
The Stainless Steel version installs and operates in exactly the same manner.
Indoor use only
Paxton
Switch2 controllers with WHITE labels are incompatible with these products. The keypads in the K and KP series,
can only be used with Switch2 controllers tted with YELLOW wiring labels.
When using this keypad style with Net2, the software version used must be v3.21 or later.
WHITE labelled Net2 control units provide 5V at the Red terminal. The Red power wire
for the reader should therefore be directly connected to the 12V ACU terminal.
Wiring
The reader port module is designed to convert the
standard reader ports on Switch2 and Net2 controllers
to accept one or two RJ45 connections. Pull off the
screw terminal block from the reader port and simply
replace it with this module.
This module can be used to provide a
connection point for the reader RJ45 plug.
The terminals on the module are then wired
colour for colour to the controller.
Alternatively, the reader can be wired directly
into the screw terminals of the control unit by
rst cutting off the RJ45 plug and stripping
back the wires in the cable.
Reader port module (325-030)
This module may be purchased separately to speed up
the installation and replacement of readers.
Connection modules
Further information on how to purchase Installer Tools is available at:
http://paxton.info/841
Reader junction box (325-020)
1 2 3
4 5 6
7 8 9
0 #
*
Connection to a control unit reader port


Produkt Specifikationer

Mærke: Paxton
Kategori: Sikkerhed adgangskontrolsystem
Model: Touchlock K38
Produktfarve: Rustfrit stål
Driftstemperatur (T-T): -20 - 55 °C
Dimensioner (BxDxH): 38 x 12.5 x 78 mm
Certificering: FCC\n
Effektkrav: 12V
Trådløs forbindelse: Ingen
Strømforbrug: 1000 mA
Sikkerhed: IPX7

Har du brug for hjælp?

Hvis du har brug for hjælp til Paxton Touchlock K38 stil et spørgsmål nedenfor, og andre brugere vil svare dig