Be wise, plug in.
Stealth installaon
Stealth installaon guide
Also applicable to: Stealth+, Stealth M, Stealth M+
Be aware:
The Stealth is specically designed
to be built in to an appliance/lighng
xture or as a permanently connected
device in the electrical installaon of
a building. Installaon should always
be executed by a registered installer
in compliance with the local electrical
code (e.g. BS 7671 or NEC).
It is required to include an overcurrent protecve device (circuit breaker),
that support a maximum rang of 16A (depending on your localisaon). Be
sure to switch o the circuit before installing the Stealth!
The product should be installed in a closed ame retardant casing with a
proper strain-relief mechanism.
Use the L↑ labelled clamp to connect the phase wire to the appliance and
connect the neutral wire to one of the ‘N’ labelled clamps. Then connect
the incoming phase wire to the clamp labelled ‘L’ and the neutral wire to
the free ‘N’ connecon.
For double phase 230V networks the second phase can be connected to the ‘N’ poles
(it will not be switched).
Informaon for the installer
Technical details
Voltage: 100-240 V~ Frequency: 50 / 60 Hz Total max. current: 16 A*
If a normal Stealth with relay is used, these addional maximum rangs apply:
• Inducve load: 4A
• Capacive load: 1A
Exceeding these rangs will adversely aect the service life of the relay!
Dimensions:
57.1 x 39 x 21 mm
ZigBee Dynamic MESH
2.4 GHz
E: helpdesk@plugwise.com T: +31(0) 252 43 30 70 W: www.plugwise.com
* Total max. current Stealth M and M+ : 20A.
All specicaons without prejudice.
See www.plugwise.com for detailed informaon.