POWEREX MH-C940 Manual


Læs gratis den danske manual til POWEREX MH-C940 (2 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 35 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 18 anmeldelser. Har du et spørgsmål om POWEREX MH-C940, eller vil du spørge andre brugere om produktet?

Side 1/2
PRINTED IN TAIWAN A03-3713510-000
Thank you for purchasing the Powerex MH-C9 Charger-40
Analyzer. Read these instructions carefully before
operating this unit.
GET STARTED VIDEO
Learn how to use the MH-C940 Charger-Analyzer
YouTube Video Link: https://youtu.be/oQFK8UqIxjQ
Or Scan the QR Code with your phone
GENERAL PRECAUTIONS
Do not charge battery cells other than NiMH or NiCD. AA
batteries must be able to accept a 1000mA (Turbo Mode)
/ 500mA (Default M charge current. AAA Batteries ode)
must be able to accept a 500mA (Turbo Mode) / 250mA
(Default Mode) charge current.
Do not use the T Mode on AA batteries rated 2 hour urbo
under 2000mAh and AAA batteries under 700mAh. To
charge them, use the Default Mode (refer to “Default
Mode”).
Do not expose the unit to rain or moisture due to the risk
of re.
Do not operate the charger if it appears damaged in any
way.
Always place the battery cells with positive tip facing the
top. Incorrect polarity may cause re or explosion.
Observe polarity diagrams located on the charger.
Do not allow the unit to be exposed to direct sunlight.
Operate in well-ventilated area.
Do not allow the battery terminals to become shorted.
To reduce the risk of damage to the power cord, always
pull by connector rather than the cord.
FEATURES & SPECIFICATIONS
Charges 1-8 AA or AAA NiMH rechargeable batteries
independent ly
2 Charging Speeds: Default Soft Mode and Turbo Mode
Deep Battery Conditioning System to rejuvenate older
batteries with capacity readout
Backlit LCD display with On/O option
Ultra quiet fanless operation with thermal protection
Turbo Charge Current:
1000mA (AA), 500mA (AAA)
Default Charge Current:
500mA (AA), 250mA (AAA)
Microprocessor:
Ninth-Generation MH-
NM7108 Powerex Precision
Microprocessor
Charge Time*:
120 Minutes (Turbo), 240
Minutes (Default)
Input Voltage:
AC 100-240V 50-60Hz
* Charge time based on 2000mAh capacity batteries. Charge
time will vary depending upon the brand, capacity, and
condition of batteries being charged.
MODES
This section explains various charging modes and when to use
them. To enable each mode, refer to the “Operation” section.
Default Mode
Soft charge to maximize battery life and
performance. Recharging time is approximately 4-6
hours.
NOTE: Time may vary depending on battery
capacity and how much charge is remaining in the
battery.
Suitable for most NiMH or NiCD batteries.
Recommended if recharging time is not critical.
Turbo Mode
Faster recharging time. Charges twice as fast as the
Default Mode, approximately 2-3 hours.
Recommended for AA NiMH batteries with capacity
of at least 2000mAh and AAA NiMH with capacity of
at least 700mAh.
Conditioning Mode
Rescues degraded batteries and exercise
infrequently used batteries.
Rejuvenates and cycles the batteries. It applies a
special conditioning cycle which restores battery
performance. Requires up to 48 hours to complete
the cycle.
Actual capacity will be displayed at the end of the
conditioning cycle.
Recommended every 6 months or once a year to
ensure battery performance.
OPERATION
Default Mode
1. Plug the power connector to the charger rst then plug
the AC adapter into the wall outlet.
2. Insert AA and/or AAA batteries. For best performance,
insert the batteries from the left to right.
3. Once the battery is inserted, charging will commence for
that slot. Each slot number will start flashing indicating it’s
charging.
The displayed mAh value represents the amount of
energy that was charged into the battery. It is NOT
the actual capacity of the battery.
4. Charging time will take approximately 4-6 hours.
Once a battery is done charging, the slot number will stop
ashing and remain solid. The charger will display DONE
for each channel that is done charging. The charged
battery may be removed for use.
The displayed mAh value represents the amount of
energy that was charged into the battery. It is NOT
the actual capacity of the battery.
MH-C940
Charger-Analyzer
PRINTED IN TAIWAN A03-3713510-000
5. The charger will go into standby mode once all batteries
are done charging. To completely turn o the unit, unplug
the unit from the wall.
Turbo Mode
Turbo Mode is activated for all battery slots simultaneously
and cannot be activated for each individual battery. It cannot
be used together with the Conditioning Mode.
NOTE: If charging has started in the Default Mode, you can no
longer change it to a dierent mode. You must reset the
charger to start over.
1. Remove all batteries from the charger, if any.
2. Insert battery in the rst left slot. ONE
3. Within ve seconds, press the TURBO button. T Turbo he
symbol will be displayed on the LCD screen.
4. Insert the remaining batteries.
The displayed mAh value represents the amount of
energy that was charged into the battery. It is NOT
the actual capacity of the battery.
5. Charging time will take approximately 2-3 hours.
6. Once a battery is done charging, the slot number will stop
ashing and remain solid. The charger will display DONE
for each channel that is done charging. The charged
battery may be removed for use.
7. The charger will go into standby mode once all batteries
are done charging. To completely turn o the unit, unplug
the unit from the wall.
NOTE: Turbo Mode will remain activated even if charging
is completed. The charger will reset to the Default M ode
when all batteries are removed (Turbo symbol
disappears) .
Conditioning Mode
Conditioning Mode is activated for all battery slots
simultaneously and cannot be activated for each individual
battery. It cannot be used together with the Turbo Mode. The
Conditioning Mode is recommended every 6 months or once a
year to ensure battery performance.
1. Remove all batteries from the charger, if any.
2. Insert battery in the rst left slot. ONE
3. Within ve seconds, press the CONDITION button. The
Condition symbol will be displayed on the LCD screen.
4. Insert the remaining batteries.
5. The Conditioning Mode can take up to hours to 48
complete.
6. The conditioning cycle has ve steps:
Step 1: C r will charge all batteries. harge
Step 2: Charger will rest for approximately 1 . hour
Step 3: Charger will condition all the batteries.
Step 4 Charger will charge all batteries. : re
Step 5 Charger will display D when the batteries are : one
fully charged. The displayed mAh capacity represents the
available capacity of the battery.
7. The charger will go into standby mode once all batteries
are done charging. To completely turn o unit, unplug the
unit from the wall.
Additional Selections
Scroll Left and Right to see battery process:
Press the CONDITION button. To scroll Left:
To scroll Right: Press the TURBO button.
The screen will remain lit for 30 seconds from your
last button press.
To permanently turn backlit screen On/O while in use:
Press and hold both the CONDITION and Turn On:
TURBO buttons simultaneously until the screen is lit.
Press and hold both the CONDITION Turn O: and
TURBO buttons simultaneously until the screen light
turns o to reset into Default Mode.
The backlit screen will go back into Default Mode
once the charger has been unplugged.
TROUBLESHOOT
= Battery Fault
Please remove batteries from the charger.
= Caution! Batteries may be hot to touch
Note which slot number has theashing number and
triangle (battery fault).
Unplug the charger.
Allow the batteries to cool down for minutes. 30
Remove the faulty battery from the slot.
WARRANTY
The MH- Charger-Analyzer has a 3-Year Limited C940
Warranty.
See website www.mahaenergy.com for more details.
Manufactured By:
MAHA ENERGY CORP.
Tel: 1- - -9992800 376
www.mahaenergy.com
Copyrighted ® 1993- Maha Energy Corp.2023


Produkt Specifikationer

Mærke: POWEREX
Kategori: Ikke kategoriseret
Model: MH-C940

Har du brug for hjælp?

Hvis du har brug for hjælp til POWEREX MH-C940 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret POWEREX Manualer

POWEREX

POWEREX MH-C940 Manual

14 Marts 2025

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer