Prestige APSSEC Manual


Læs gratis den danske manual til Prestige APSSEC (25 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 7 personer og har en gennemsnitlig bedømmelse på 5.0 stjerner ud af 4 anmeldelser. Har du et spørgsmål om Prestige APSSEC, eller vil du spørge andre brugere om produktet?

Side 1/25
Installaon and Reference Guide
2020 Voxx Electronics Corporaon. All rights reserved. APSSEC_RevC_07/20
2 Wire Harness Colors and Funcons
2 Power / Nocaon Connector
3 Input / Output Connector
6 External Components
6 Shock Sensor
6 RF Antenna Kit
6 Data Bus Interface (DBI)
6 Telemacs
7 Setup Opons
7 Remote Programming
8 Security Control
12 Negave Output Control (NOC)
14 AUX Output Control
15 PIC Input Control
16 System Operaon
16 Remote Operaon
APSSEC
Vehicle Security / Keyless Entry System
17 System Programming
17 Programming Mode Entry / Exit
18 Feature Bank Opons
18 Data Port Protocol Selecon
19 Dome Light
19 Silent Arm and Disarm
19 User Selectable LED
19 System Diagnoscs
19 Troubleshoong Trigger Zones
19 Adjusng Shock Sensor
20 Alarm Override Procedures
21 Wiring Diagrams
21 Door Lock Connecons
24 Starter Kill Relay
25 Full System Connecons
Thank you for trusng Presge products! If you are a consumer, please note:
Professional installaon is strongly recommended.
This manual assumes the installer has adequate knowledge of the following experse. Therefore, it does not
cover these topics in detail:
12-volt electronics
Tesng and verifying circuits
Making safe and lasng wiring connecons
Factory ignion, power, lighng, data bus and sensing systems
Factory systems and components to avoid
Safe wire roung, circuit protecon and product placement
Access to vehicle-specic technical informaon
In addion, this manual assumes the installer has the proper tools, skill and facilies to perform a professional installaon.
Performing an improper installaon could result in damage to the vehicle or its components, improper system funcon,
unsafe vehicle operaon or physical injury. Such instances would not be covered by the vehicle manufacturer's warranty,
nor by Voxx Electronics, Inc.
Detailed Descripons Quick Reference
APSSEC_RevC_07/20
2
Detailed Descripons: Wire Harness Colors and Funcons
4. YELLOW – Ignion Input (+)
The YELLOW wire connects to the vehicle's primary ignion wire. This wire will be used for system programming and
override.
Vericaon: This ignion wire registers 12-Volt (+) when the key is in the accessory, ignion, and start posions.
Note: Before making this connecon, remove all module fuses unl the system is completely connected.
6. RED – 12-Volt Input (+)
The RED wire connects to the vehicle’s primary 12-Volt (+) wire to power the system.
Vericaon: The power wire registers 12-Volt (+) at all mes.
Note: Before making this connecon, remove all module fuses unl the system is completely connected.
1 3 5
2 4 6
Power / Nocaon Connector (6-pin connector) See page 25 for the full system diagram.
These wires are listed in order of their placement in the harness connector.
3. WHITE/RED – Parking Light Relay Input (Internal Relay Pin 87)
The WHITE/RED connects to vehicle 12-Volt (+) or Ground (-) to supply the relay output (WHITE wire).
Vericaon for default seng:
If the vehicle parking light wire registers 12-Volt (+) when the park lights are on, connect the WHITE/RED wire to a
constant 12-Volt (+) vehicle wire.
If the vehicle parking light wire registers Ground (-) when the park lights are on, connect the WHITE/RED wire to a
reliable vehicle ground source.
Note: This wire can be programmed to perform the Trunk Release Output funcon by changing its opons. Refer to
Bank 2, Feature 14 on page 8.
1. WHITE – Parking Light Relay Output (Internal Relay Pin 30)
At its default seng, the WHITE wire supplies 12-Volt (+) or Ground (-) to the vehicle's park light wire based on the
connecon of the relay input (WHITE/RED wire).
Vericaon: The vehicle parking light wire registers 12-Volt (+) or Ground (-) when the park lights are turned on.
Note: This wire can be programmed to perform the Trunk Release Output funcon by changing its opons. Refer to
Bank 2, Feature 14 on page 8.
2. BLACK – Ground Input (-)
The BLACK wire connects to a reliable vehicle ground (-) source to power the system.
Vericaon: The vehicle ground (-) source wire registers ground (-) at all mes.
Note: Before making this connecon, remove all module fuses unl the system is completely connected.
5. WHITE/BLACK – Siren Output (+)
The WHITE/BLACK wire supplies 12-Volt (+) to power the siren. Aer mounng the siren, connect its BLACK wire to a
reliable ground source, and connect the BROWN wire to the siren’s RED wire.


Produkt Specifikationer

Mærke: Prestige
Kategori: Ikke kategoriseret
Model: APSSEC

Har du brug for hjælp?

Hvis du har brug for hjælp til Prestige APSSEC stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Prestige Manualer

Prestige

Prestige APSSEC Manual

5 August 2025
Prestige

Prestige APSRS Manual

5 August 2025
Prestige

Prestige APSSECRS Manual

5 August 2025

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer