Læs gratis den danske manual til Rane RPM 26v (24 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 2 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 1.5 anmeldelser. Har du et spørgsmål om Rane RPM 26v, eller vil du spørge andre brugere om produktet?

Side 1/24
Manual-1
OPERATORS MANUAL RPM 26v
DSP MULTIPROCESSOR
Windows
is a registered trademark of Microsoft Corporation; RaneWare is a registered trademark of Rane Corporation.
SYSTEM REQUIREMENTS
RaneWare works under Microsoft Windows
®
, on a PC or
laptop with an unused serial port.
RW 232, RaneWare’s protocol, uses a DB-9 cable less
than 50 feet long, connecting from the serial port of a com-
puter to the RPM 26v communications Input port. No
interface boxes are required; just a cable and your computer.
RaneWare can be fully demonstrated and used without an
actual RPM 26v attached. Simply select the OFFLINE
RPM 26v or any other OFFLINE unit under Select in the
Device menu.
A RaneWare CD comes with each unit. Installation is
simple. The latest version is downloadable 24 hours a day
from Rane’s Internet site: http://www.rane.com.
QUICK START
If you don’t read all of this document, you risk setting up your system improperly. But at least read this section and the
Input Trim section on page Manual-13. Paying careful attention to your system’s gain structure and setting the RPM’s
Input Trim properly are essential in maximizing the noise performance of your entire system. (See the enclosed RaneNote
“Setting Sound System Level Controls”.) Once you’re done reading and memorizing the manual, please recycle the paper it
is printed on by reconing an old speaker. If RaneWare has not yet been installed on your computer, refer to STEP BY
STEP RANEWARE INSTALLATION on page Manual-2 first.
Leave the audio connections on the RPM 26v until last. Connect the RW 232 INPUT jack on the unit’s rear to a serial
(COM) port on a PC-compatible computer using a standard 9-pin RS-232 cable. A short one is supplied with the unit,
which is intended to connect between units in a rack. The cable and adapter must not be a null-modem type.
Locate the RW 232 DEVICE ADDRESS switch on the rear panel. If this unit is to be used by itself, set the switch to
1’ by setting all switches off (down), except switch one (labeled ‘1’ on the chassis, the right-most switch when viewed
from the rear). If there is more than one unit, refer to Device Address Calculator in the software’s Help system or run
the included Device Address Calculator software and set a unique address for each unit.
Apply power by connecting the RS 3 remote supply’s 5-pin DIN jack to the rear of the unit, then connect the IEC end
to a powered AC outlet. CAUTION: Do not connect anything but an approved Rane power supply to this jack. The unit
does ground the chassis through the power cord. If the RS 3 and the RPM 26v are getting power, the yellow front panel
POWER indicator will be on.
Start your computer, run Windows
®
, and launch RaneWare by double-clicking on the RaneWare™ umbrella icon.
(See the next page for software installation instructions.) The Help file’s Software License Agreement appears the first
time RaneWare is run — read it all and close it. Then the System Setup window may appear. If it doesn’t, select
System Setup from the System menu. Be careful to select the COM port which is physically connected to the RPM 26v.
Click OK. Now, the Device Selection window may appear. If it doesn’t, choose Select from the Device menu. Click on
Poll and the Devices Found: displays the units found. Click the Stop button to stop Polling. Select the unit from the
Device Selection window and click OK. If no unit was found, please refer to the TROUBLESHOOTING section at the
end of this manual or in the software’s Help system.
Several clues indicate communication between the computer and the RPM 26v. The yellow COM (communications)
indicator on the front of the unit flashes or stays on. The Memory numbers (1-16) near the top of the computer screen will
be black rather than gray. The Active indicator at the bottom left of the computer screen will be green.
Important Note: The RPM 26v contains many insightful, preprogrammed DSP Programs. Each “fixed” DSP Program
can be thought of as a unique “system setup,” i.e., 2-way crossover system, 3-way system, 2 x 6 splitter, etc. Each of the 16
Memories can contain a different DSP Program. Before connecting the RPM 26v to the other audio components in your
system, it is wise to choose and store the appropriate DSP Program for your system in all 16 Memories. This avoids the
problem of accidentally recalling a Memory that restores an undesired DSP Program, such as the case where you recall
from a 3-way DSP Program to a splitter: this sends full-range audio to all Outputs!
Once the proper DSP Program is stored in the RPM’s Memories, audio connections can be made. Turn the amplifier(s)
off until all connections are complete. Connect balanced audio INPUTS and OUTPUTS to the Euroblocks on the rear.
Note: If you have previously
installed an older version of RaneWare
and you just received a new RPM 26v
unit, you must reinstall the new version
of RaneWare that was shipped with
your unit. Use of an old version will
not work.
WEAR PARTS: This product contains no wear parts.
Manual-2
FRONT PANEL DESCRIPTION
Signal/Overload multi-color LEDs indicate the presence of a significant audio Signal (green) or Overload conditions (red).
Both Input and Output indicators are provided for signal flow verification without a computer. The Inputs’ Signal indicators
are driven from an analog comparator circuit prior to the input level control. All other indicators are controlled from the
microprocessor.
The Output indicators cycle yellow from left to right during power up and when the unit is loading a new DSP Program.
All outputs are muted during DSP Program changes.
If Output 1 or 2 is flashing, something has gone wrong. See TROUBLESHOOTING on page Manual-22.
COM (yellow, communications) flashes when a message for the unit is successfully received. This indicator flashes often
when communicating with the computer, since metering messages are continually requested by the computer. The COM
indicator may flash so often it may appear to be constantly on. There is also a brief flash whenever the Memory Recall Port
is used.
POWER indicates that the unit is connected to a powered RS 3 remote supply.
RPM 26v CONNECTION
When connecting the RPM 26v in your system, leave its
power supply and the amplifiers for last. This gives you a
chance to correct mistakes before damage is done to your
amps, speakers, ears, etc. Also, be sure to read the Important
Note in the QUICK START section on page Manual-1.
The RPM 26v has balanced Inputs and Outputs, with
shields connected to the chassis through three #4 serrated
screws on the rear. Keep these screws tight for the best
possible shield-to-chassis connections. The RS-232 cable
shields connect to the chassis through the four nuts and star
washers that the cable screws into. Be sure to screw down
RS-232 cables to guarantee good shield connections. The
chassis and the audio signal ground are connected together
internally at only one point. The RPM 26v chassis connects
through the RS 3 power supply cables to the earth ground (3
rd
pin) of the 100 and 120 VAC line cords. A 6-32 screw and
star washer are also provided on the unit’s rear if a technical
ground connection is needed. This chassis connection is also
recommended for 230V operation. Connect the non-inverting
(positive) audio lines to the ‘+’ terminals, and the inverting
(negative) lines to the ‘’ terminals. Connect the cable shields
to the center terminal on the Euroblock. For those installa-
tions where the RPM 26v internal shield-to-chassis connec-
tion causes interference, connect the shields directly to the
chassis PEM nuts directly above each shield terminal. Be sure
to bite through the paint with the star washer and keep the
shields wrapped around the audio conductors as much as
possible. For the “theoretical” best ElectroMagnetic Interfer-
ence (EMI) immunity, connect the shields at both ends of the
cables. (For more information on System Connections, see
RaneNote 110, “Sound System Interconnection” later in this
manual or on Rane’s web site at www.rane.com.)
For those systems where Murphy and his EMI pests have
arisen or for those who wish not to tempt fate, the RPM 26v
accepts optional line level input isolation transformers (Rane
part #00961). Call your Rane dealer for more information on
the optional transformers.
To control the unit from a computer, use 9-pin RS-232
cables which are 50 feet or shorter. The cable and adapter
must not be a null-modem type. A short cable is supplied for
connecting adjacent units. Daisy-chain up to 16 units at a
time by connecting the computer COM port to the RW 232
INPUT connector on the first unit. Then connect the unit’s
RW 232 OUTPUT connector to the next unit’s RW 232
INPUT.
The DEVICE ADDRESS switch identifies each unit with
an ‘address’, and must be set uniquely for each unit. The
switches form a binary code from 0 through 255. Only the
numbers 1 through 250 may be used. The place values of
each switch are marked on the rear panel. The switch itself
may have numbers printed on it; these should be ignored. To
set a specific address, refer to the SETTING THE DEVICE
ADDRESS section on page Manual-24 or run the Address
Calculator software included with RaneWare.
Refer to page Manual-23 for information regarding switch
connections to the Memory Recall Port (MRP).


Produkt Specifikationer

Mærke: Rane
Kategori: Ikke kategoriseret
Model: RPM 26v

Har du brug for hjælp?

Hvis du har brug for hjælp til Rane RPM 26v stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Rane Manualer

Rane

Rane AD 22 Manual

20 Juni 2025
Rane

Rane MS 1 Manual

20 Juni 2025
Rane

Rane FAC 24 Manual

19 Juni 2025
Rane

Rane DC 24 Manual

19 Juni 2025
Rane

Rane MLM 42 Manual

19 Juni 2025
Rane

Rane RPS 4 Manual

19 Juni 2025
Rane

Rane Via 10 Manual

19 Juni 2025
Rane

Rane BB 44X Manual

19 Juni 2025
Rane

Rane THX 22 Manual

19 Juni 2025
Rane

Rane TTM 57SL Manual

19 Juni 2025

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer