Læs gratis den danske manual til Regency Greenfire GF1500L (76 sider) i kategorien Varmeapparat. Denne vejledning er vurderet som hjælpsom af 19 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 10 anmeldelser. Har du et spørgsmål om Regency Greenfire GF1500L, eller vil du spørge andre brugere om produktet?

Side 1/76
920-353b
Greenfire
®
GF1500L
Gas Fireplace
03.01.22
www.regency-fire.com.au
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
LISTINGS AND CODE APPROVALS
These gas appliances were tested in accordance
with AS/NZS 5263.0 & AS/NZS 5263.1.3/ and
certified by the Australian Gas Association for
installation and operation as described in these
instructions. Must be installed as per AS/NZS
5601.
Your unit should be serviced annually by an
authorised service person.
Owners &
Installation Manual
MODELS: GF1500NG Natural Gas GF1500LLP-2 GF1500LULPG-2 Propane
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch: do not use any phone in your building. Leave the building immediately.
Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Warning
Fire or explosion Hazard
failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
owner's information
To the New Owner:
Congratulations!
You are the owner of a state-of-the-art gas fireplace by REGENCY
®
. The GF1500L has been designed to provide you with all
the warmth and charm of a wood fireplace at the flick of a switch. The GF1500L was approved by AGA for both safety and
efficiency. As it also bears our own mark, it will provide you with economy, comfort, and security for many trouble-free years to
come. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency
®
Fireplace.
PAIRING YOUR REMOTE CONTROL
The control box will only learn the Remote ID codes during the first 30 seconds after power is applied
and will ignore this special command from the Remote after the first 30 seconds.
To match the control box to the remote, follow the steps below :
1. Remove a battery from the remote handset.
2. Remove main power to the control box by turning off the isolation switch or switch on the GPO to
the heater.
3. Wait 30 seconds (approx.).
4. Reconnect main power to the control box.
5. Immediately put the battery back in the remote & point the remote in the direction of the heater.
6. Press and hold the PROG and FAN buttons simultaneously. The
letters “LC” will appear on the display indicating the ID codes have
been transmitted.
7. Release both buttons.
8. The display will revert back to the normal off mode display. The
heater should light spark, burner, etc even though the remote
screen says the heater is off.
9. Press the Off button on the remote. The heater should turn off.
10. Wait approx. 30 seconds turn the on again & check all the functions
work fan speed can be adjusted, flame height can be adjusted, etc.
Note: To view a step-by-step pairing video please visit
regency-fire.com.au/Customer-Care/Fireplace-Care-Videos
Note: The Remote Control Handset has a set of unique ID codes that is
pre-programmed into its memory. This set of ID codes helps to differen-
tiate one Remote Control Handset from another so that only the control
box with a matching ID code will respond to the appropriate Remote
Control Handset.
regency.com.au
Pairing Your Remote Control
The control box will only learn the remote ID codes during the first 30 seconds after power is
applied. After the first 30 seconds, the control box will ignore this special command.
The remote control handset has a set of unique ID codes that are pre-programmed into its
memory. This set of ID codes helps differentiate one remote control handset from another.
Only the control box with a matching ID code will respond to the appropriate remote control
handset.
To match the control box, follow these steps:
1. Ensure the remote is siwtched off.
2. Remove the main power to the control box.
3. Reconnect the main power to the control box.
4. Press and hold the PROG and FAN buttons simultaneously. The temperature display will
show the letters "LC", indicating the ID codes were transmitted, then revert to the normal
off mode display.
5. Release the PROG and FAN buttons.
The control box will only learn the remote ID codes during the first 30 seconds after power is
applied and will ignore this special command from the remote afterward.
Fan Operation
The fan must be on while the unit is in operation. This model offers a two-speed fan.
NOTES
The heater turns off when the room temperature reaches 1 C over the set temperature and turns
back on when the room temperature reaches 0.50 C under the set temperature when in AUTO mode.
The pairing process can be carried out by anyone.
Please visit www.regency-fire.com.au to see the pairing video.