T710 Access Point
Quick Setup Guide
This Mounting Guide provides step-by-step instructions on how to 
field-install the Ruckus Wireless T710 access point (AP).
For detailed information on planning the installation, performing a site 
survey, and operating the T710, refer to the ZoneFlex Outdoor Access 
Point User Guide, available at https://support.ruckuswireless.com
.
WARNING: Only trained and qualified personnel should be allowed to 
install, replace, or service this equipment. 
WARNING: Installation of this equipment must comply with local and 
national electrical codes. 
CAUTION: Make sure that you form a 80mm - 130mm (3”-5”) drip 
loop in any cable that is attached to the AP or the building. This will 
prevent water from running along the cable and entering the AP or the 
building where the cable terminates. 
CAUTION: Be sure that grounding is available and that it meets local 
and national electrical codes. For additional lightning protection, use 
lightning rods and lightning arrestors. 
CAUTION: Make sure that proper lightning surge protection 
precautions are taken according to local electrical code. 
WARNING: Ruckus Wireless strongly recommends that you wear eye 
protection before mounting the T710.
THIS GUIDE IN OTHER LANGUAGES
请从以下网站获得该指南的简体中文版 
https://support.ruckuswireless.com
.
Vous trouverez la version française de ce guide à l'adresse suivante 
https://support.ruckuswireless.com
.
こ の ガ イ ド の⽇本語版は https://support.ruckuswireless.com
 
でご覧く ださい。
이 가이드의 한국어 버전은 웹 사이트
(https://support.ruckuswireless.com
) 에서 확인하시기 바랍니다 .
Veja a versão em português (Brasil) deste guia em 
https://support.ruckuswireless.com.
Puede ver la versión en español (América Latina) de esta guía en 
https://support.ruckuswireless.com.
BEFORE YOU BEGIN
Before deploying your Ruckus Wireless T710, verify that all items listed 
in Package Contents
 are included in the package. If any item is 
damaged or missing, notify your authorized Ruckus Wireless sales 
representative. Also, make sure that you have the required hardware 
and tools. 
REQUIRED HARDWARE AND TOOLS
• Customer-supplied outdoor-rated three-wire (1-2mm
2
 or 14-
18AWG) AC cable
• 1/2” (13mm) flat-blade screwdriver or equivalent
• No. 2 Phillips screwdriver
• Small flat-blade screwdriver
• Torque wrench or torque screwdriver with sockets
• Long-nose pliers
• Electrical wire stripping and terminal crimping pliers
• Pipe or pole --OR-- a sturdy flat surface
• Electric drill with drill bits and customer-supplied wall anchors, flat 
washers, and hex nuts for flat-surface mount
• Four factory-supplied 1/2” (12.7mm) wide stainless steel 
adjustable clamps, 2.5” (63.5mm) diameter, for main mounting 
bracket on smaller poles
•Ruler
PACKAGE CONTENTS
A complete T710 field installation package includes all of the items 
listed below (see Figure 1for illustrations):
• T710 Access Point (A)
• M25 data cable gland extender (B)
• Three M25 data cable glands (C)
• Outdoor AP Mounting Bracket (D), consists of:
• Mounting bracket
•U-joint bracket
• Linkage bracket
•AP bracket
• AC Power Cable End Connector (E)
• Cable Gland Extender Flat Gasket (F)
• Safety cable kit (G)
• One ground wire with lug (H)
• Service Level Agreement/Limited Warranty Statement
• Regulatory Statement
• Ruckus Wireless AP Getting Started Guide
• Declaration of Conformity
•This Quick Setup Guide
Figure 1: Package Contents
STEP 1: CONNECTING AND SEALING THE RJ-45 
C
ABLES
The T710 may use zero, or one or two RJ-45 cables, one for Ethernet 
when configured as a Root AP (RAP), and another when the T710 is 
supplying PoE out to a peripheral device, such as a small cell or micro 
cell radio. When the T710 uses RJ-45 cables, connect and seal the 
cables using the M25 data cable glands as shown in Figure 3.
WARNING: Do not use any PoE injector not tested and approved by 
Ruckus Wireless to power the T710 Access Point. 
WARNING: Do not plug PoE IN power into the PoE OUT port. See 
Figure 2.
WARNING: If using PoE OUT, it is MANDATORY to use the custom 
Ruckus supplied 60W PoE injector (part #902-0180-XX00), or to use 
AC power.
WARNING: If using a PoE switch to supply power to the T710, 30W 
MUST be reserved for the T710 on the switch. Failure to ensure a 
30W supply may result in unpredictable operation of the access point. 
Additionally, if using a PoE switch, the T710’s PoE OUT port cannot be 
used to power additional devices. 
Figure 2: PoE IN and PoE OUT ports 
1 Feed the end of the cable through the sealing nut, rubber O-ring, 
clamping ring assembly and cable gland base as shown in Figure 
3.
CAUTION! The minimum software revision for the T710 
is ZoneFlex (ZF) 9.13 or later, or SmartZone (SZ) 3.4 or 
later. 
DO NOT CONNECT THE T710 TO A RUCKUS 
WIRELESS ZONEDIRECTOR RUNNING 9.12.2 OR 
EARLIER.