FOREWORD
This manual is for use by qualifi ed personnel and contains information and tips to use and keep your coffee maker as effi ciently as possible. Please read
all instructions very carefully before you actually use your machine to make sure the machine works properly and to ensure a long working life. Instruc-
tions are part of the product. Please keep this document. This booklet refers to the following models:
Model – CAPRI DELUXE SAP
Semiautomatic with continuous dispensing and solenoid valve controlled by rocker switch located on the control panel. Available in 1, 2 group versions.
Model – CAPRI DELUXE SED
Microprocessor-controlled electronic model with programmable dosing through a keypad with indicator lights. Available in 1, 2 group versions.
SPECIFICATIONS
GROUPS 1 2
Width (X) mm 430 600
Depth (Y) mm 485 485
Height (Z) mm 535 535
Capacity litres 4,5 10
Net weight Kg 38 49
Gross weight Kg 41 53
Voltage V 120/230/400 120/230/400
Heating element input kW 1,95/2,4 2,7/4,5
Electric pump input kW 0,15 0,15
Power absorbed by the external electric pump kW 0,15 0,15
Solenoid valve input kW 0,0135 0,0225
Automatic level controller input kW 0,01 0,01
Boiler design pressure (2 Bar) MPa 0,2 0,2
Boiler working pressure (0,8-1 Bar) MPa 0,08:0,1 0,08:0,1
Safety valve calibration pressure (1,8 Bar) MPa 0,18 0,18
Exchanger design pressure (20 Bar) MPa 2 2
Exchanger safety valve calibration pressure (12 Bar) MPa 1,2 1,2
Mains water pressure (max) (6 Bar) MPa 0,6 0,6
Coffee dispensing pressure (8-9 Bar) MPa 0,8/0,9 0,8/0,9
The weighted sound pressure level A of the coffee machine is less than 70dB.
For correct appliance operation and trouble-free maintenance, please read this booklet carefully and comply with the instructions and rules, also referring
to the diagrams given in it.
INSTALLATION
Before installing the appliance ensure that the mains voltage and power correspond to the data given in the specifi cations table. Take the appliance out of
the packaging and put it in its fi nal place of installation ensuring that it is stable and safe and that there is the necessary space for using it.
Place the machine in a way that the distance between the grid and the fl oor is wider than 1,5 mt. To clean the internal circuit more effi ciently, you are
recommended to empty and fi ll the boiler a number of times and deliver simple water and coffee to be thrown away.
ENGLISH