Satco S16434 Manual

Satco overvåge S16434

Læs gratis den danske manual til Satco S16434 (4 sider) i kategorien overvåge. Denne vejledning er vurderet som hjælpsom af 2 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 1.5 anmeldelser. Har du et spørgsmål om Satco S16434, eller vil du spørge andre brugere om produktet?

Side 1/4
1
of the lamp is powered, and securely connected to the
powered R17d lamp holders (120V-277V).
STEP 9: Make sure all sockets are wired according to the
appropriate wiring diagram (Figures 1/1a – 4/4a).
STEP 10: Reinstall the ballast cover to hide all wires.
STEP 11: Install your new single and double ended LED T8
replacement lamps.
STEP 12: Apply
visible location inside
the xture.
STEP 13: Reinstall lens
or diffusion cover on the
light xture.
STEP 14: Turn power
ON at the breaker box.
STEP 15: Turn on the lights.
OMNI
-
DIRECTIONAL LED T8 TUBES
Models: S16430, S16431, S16432, S16433, S16434, S16435, S16436,
S16437, S16438, S16439, S16440, S16441, S16442, S16443
Satco Products, Inc.
Brentwood, NY 11717© Copyright 2023 Satco Products, Inc. 3/23 v1.2
WARNING:
DANGER: Risk of shock-disconnect power before
installation.
WARNING: Risk of re or electric shock. LED Retrot
Kit installation requires knowledge of luminaire electrical
systems. If not qualied, do not attempt installation.
Contact a qualied electrician.
WARNING: Product must be installed in accordance with
the national electrical code or your local electrical code.
If you are not familiar with these codes and requirements,
contact a qualied electrician.
WARNING: Install this kit only in luminaries that have
the construction features and dimensions shown in the
photographs and/or drawing and where the input rating
of the retrot kit does not exceed the input rating of the
luminaire.
WARNING: To prevent wiring damage or abrasion, do
not expose wiring to edges of sheet metal or other sharp
objects. Do not make or alter any open holes in any
enclosure of wiring or electrical components during kit
installation.
WARNING: To avoid potential re or shock hazard, please
confirm the type of lamp holder before installation. If it is a
shunted lamp holder, refer to double-ended wiring.
NOTE: Shunted lamp holders are found only in
uorescent luminaries with instant-start ballasts. Instant-
start ballasts can be identied by the words “Instant
Start” or “I.S.” marked on the ballast. This designation
may be in the form of a statement pertaining to the
ballast itself, or may be combined with the marking for
the lamps with which the ballast is intended to be used,
for example F40T 12/IS, for more information contact the
LED luminaire retrot kit manufacturer.
If it is non-shunted lamp holder, refer to single or
double-ended wiring.
Installers should not disconnect the existing wire from
lampholder terminals to make new connections at
lampholder terminals. Instead installers should cut
existing lampholder leads away from the lampholder and
make new electrical connections to lampholder lead wires
by employing applicable connectors.
WARNING: Luminaire wiring and electrical parts may be
damages when installing retrot kit hardware. Check for
enclosed wiring and components.
WARNING: Check the existing wiring for damage before
installing upgrade kit. Do not install if existing wires are
damaged. This retrot kit is accepted as a component of
a luminaire where the suitability of the combination shall
be determined by authorities having jurisdiction.
“This luminaire has been modied and can no longer
operate the originally intended lamp,” shall be marked
on the retrot luminaire where readily visible by the user
during normal maintenance including lamping.
Do not use with dimmers.
Suitable for damp locations. Suitable for use in enclosed
luminaries.
This device is not intended for use with emergency exits.
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received,
including interference that may cause undesired
operation.
INSTALLATION AND SAFETY INSTRUCTIONS
IMPORTANT: Read before installing xture. Retain for future reference.
INSTALLATION: (See diagrams on back)
STEP 1: Make sure the circuit breaker that
supplies the power to the xture is turned OFF.
STEP 2: Before installation, select your preferred CCT
by moving the switches on both ends of the lamp to
either 4000K, 5000K or 6500K.
STEP 3: Remove lens or diffuser cover (if applicable).
STEP 4: Open/Remove ballast wiring compartment cover.
STEP 5: Identify the Line and Neutral wires running power
is OFF using a voltmeter.
STEP 6: Cut all wires connected to the ballast, and
remove ballast (and starter if present). Dispose of ballast
and uorescent lamps in accordance with government
regulations in your area.
STEP 7: Ensure that the xture contains R17d lamp holders.
STEP 8: These T8 LED lamps are designed for single
ended wiring (Figure 1) and double-ended wiring
(Figure 1a). When installing, conrm only the input end
2
Figure 2: Retrot with TWO Lamps
Figure 4: Retrot with THREE/FOUR Lamps +
TWO Ballasts
Figure 3: Retrot with THREE/FOUR Lamps
Figure 1: Retrot with ONE Lamp
Single-ended connection (non-shunted sockets)
Double-ended connection (shunted or non-shunted sockets)
Figure 2a: Retrot with TWO Lamps
Figure 4a: Retrot with THREE/FOUR Lamps +
TWO Ballasts
Figure 3a: Retrot with THREE/FOUR Lamps
Figure 1a: Retrot with ONE Lamp


Produkt Specifikationer

Mærke: Satco
Kategori: overvåge
Model: S16434

Har du brug for hjælp?

Hvis du har brug for hjælp til Satco S16434 stil et spørgsmål nedenfor, og andre brugere vil svare dig




overvåge Satco Manualer

Satco

Satco S13165 Manual

30 Marts 2025
Satco

Satco S16434 Manual

30 Marts 2025
Satco

Satco S23165 Manual

30 Marts 2025
Satco

Satco S23168 Manual

30 Marts 2025
Satco

Satco S16503 Manual

30 Marts 2025
Satco

Satco S23167 Manual

30 Marts 2025
Satco

Satco S13167 Manual

30 Marts 2025
Satco

Satco S11969 Manual

30 Marts 2025
Satco

Satco S13163 Manual

30 Marts 2025
Satco

Satco S16438 Manual

30 Marts 2025

overvåge Manualer

Nyeste overvåge Manualer