Satco S18412 Manual

Satco overvåge S18412

Læs gratis den danske manual til Satco S18412 (4 sider) i kategorien overvåge. Denne vejledning er vurderet som hjælpsom af 13 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 7 anmeldelser. Har du et spørgsmål om Satco S18412, eller vil du spørge andre brugere om produktet?

Side 1/4
1
LED T8 U-BEND LAMPS
Model: S18412
INSTALLATION AND SAFETY INSTRUCTIONS
IMPORTANT: Read before installing xture. Retain for future reference.
Item Number-Description Overall Dimensions (mm) Operating Temperature CCT Volts
S18412-13T8 /U3/L ED/CCT/BP 92 x 562.1 x 572.3 20ºC ~ 45ºC 30K, 40K, 50K 120V277V
WARNING
DANGER: Risk of shock-disconnect power before
WARNING: Risk of re or electric shock. The
electrical rating of these products are 120-277Vac,
the installer must determine whether they have
120-277Vac at the luminaire before installation.
WARNING: Risk of re or electric shock.
LED Retrot Kit installation requires knowledge of
luminaire electrical systems. If not qualied, do not
attempt installation. Contact a qualied electrician.
WARNING: Product must be installed in
accordance with the national electrical code or
your local electrical code. If you are not familiar with
these codes and requirements, contact a qualied
electrician.
WARNING: Install this kit only in luminaries that
have the construction features and dimensions
shown in the photographs and/or drawing and
where the input rating of the retrot kit does not
exceed the input rating of the luminaire.
WARNING: To prevent wiring damage or abrasion,
do not expose wiring to edges of sheet metal or
other sharp objects.
WARNING: To avoid potential re or shock hazard,
do not use this retrot kit in luminaries employing
shunted bi-pin lampholders. NOTE: Shunted lamp
holders are found only in uorescent luminaries
with instant-start ballasts. Instant-start ballasts can
be identied by the words “Instant Start” or “I.S.
marked on the ballast. This designation may be in
the form of a statement pertaining to the ballast
itself, or may be combined with the marking for
the lamps with which the ballast is intended to be
used, for example F40T 12/IS, for more information
contact the LED luminaire retrot kit manufacturer.
Do not make or alter any open holes in an
enclosure of wiring or electrical components during
kit installation.
Installers should not disconnect the existing wire
from lampholder terminals to make new connections
at lampholder terminals. Instead installers should cut
existing lampholder leads away from the lampholder
and make new electrical connections to lampholder
lead wires by employing applicable connectors.
WARNING: Luminaire wiring and electrical
parts may be damages when installing retrot
kit hardware. Check for enclosed wiring and
components.
WARNING: Check the existing wiring for damage
before installing upgrade kit. Do not install if existing
wires are damaged.
This retrot kit is accepted as a component of a
luminaire where the suitability of the combination
shall be determined by authorities having
jurisdiction.
Type B Lamp – this LED tube is intended to replace
uorescent tube lamps with ANSI designation.
Do not use with dimmers.
Suitable for damp locations.
Not for emergency lighting.
Satco Products, Inc.
Brentwood, NY 11717© Copyright 2023 Satco Products, Inc. 1/23 v1.2
2
INSTALLATION: BYPASSING MAGNETIC/ELECTRONIC BALLAST
Magnetic Ballast
STEP 1: Turn OFF power before installation.
STEP 2: Remove the existing ballast and existing starter (if present) from the xture.
CAUTION: Use only non-shunted lampholders for Single-Ended wiring installations. Do not perform Single-Ended
wiring installation of product in a xture with shunted lampholders (found in all xtures using instant start ballasts).
If the existing lampholders are shunted and Single-Ended wiring is desired, remove and replace them with non-
shunted lampholders (or remove the external shunt if applicable). Make new connections directly to lampholder
terminals as shown in Figure 1 below. After wiring modication is completed, attach the replacement cautionary
label onto a visible place on the xture and remove any pre-existing labels.
Electronic Ballast
The wiring can be single end or double end.
The connection method refers to Step 3.
Single-end: Leads 1 connected to L;
Leads 2 connected to N; Leads 1 and 2
at the end of the lampholder with LN.
Double-end: Leads 1 or 2 connected to L;
Leads 3 or 4 connected to N.
STEP 3: Rewire the xture to be one certain single end/double end power.
STEP 4: Install the LED U-bend.
STEP 5: Turn ON the power. Installation is complete.
Single End Double End
If it is a non-shunted
socket, it can work in
both single end and
double end.
If it is a shunted socket,
it is double end only,
Figure 1 Figure 2


Produkt Specifikationer

Mærke: Satco
Kategori: overvåge
Model: S18412

Har du brug for hjælp?

Hvis du har brug for hjælp til Satco S18412 stil et spørgsmål nedenfor, og andre brugere vil svare dig




overvåge Satco Manualer

Satco

Satco S13165 Manual

30 Marts 2025
Satco

Satco S16434 Manual

30 Marts 2025
Satco

Satco S23165 Manual

30 Marts 2025
Satco

Satco S23168 Manual

30 Marts 2025
Satco

Satco S16503 Manual

30 Marts 2025
Satco

Satco S23167 Manual

30 Marts 2025
Satco

Satco S13167 Manual

30 Marts 2025
Satco

Satco S11969 Manual

30 Marts 2025
Satco

Satco S13163 Manual

30 Marts 2025
Satco

Satco S16438 Manual

30 Marts 2025

overvåge Manualer

Nyeste overvåge Manualer