Sauermann PE-5200 Manual

Sauermann Pomp PE-5200

Læs gratis den danske manual til Sauermann PE-5200 (36 sider) i kategorien Pomp. Denne vejledning er vurderet som hjælpsom af 19 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 10 anmeldelser. Har du et spørgsmål om Sauermann PE-5200, eller vil du spørge andre brugere om produktet?

Side 1/36
PE 5000 PE 5100 - - PE 5200
Cod. 0000136282
Instruction Manual
Manuel D’Instruction
Manuale Istruzioni
Manual de Instrucciones
Handbuch
руководство по эксплуатации
Parc d'Activités de l'Orée de Chevry - Route de Férolles - 77173 CHEVRY-COSSIGNY
Tel: (+33) 01 60 62 06 06 - fax: (+33) 01 60 62 09 09
http://www.sauermann.fr - e.mail: info@sauermann.fr
0000136282_ 110117rev.2.3_
English
The PE range of Peristaltic pumps are designed to remove condensate water. They are particularly adapted
for use in Air Conditioning, Evaporator & Refrigerated cabinet applications.
Characteristics:
ùFlow 6 l/h
ùMax Discharge Head.: 12 m
ùMax Suction Height: 2 m
ùPower Supply: 230 V~ - 50/60 Hz
ùMotor Power Level: 11 W
ùIP 65
ùMax Design Ambient Temperature: 5 C
0. SECURITY
0.1 In any case PE series peristaltic pumps have not to run continuously
0.2 Sauermann recommends to use a security system (Floating alarm ACC00601 NO/NC 10 Amp 230
Vac (optional; see fig.8) or similar) allowing to stop the unit and prevent the overflowing whenever
an excessive amount of condensate is produced. The PE 5200 pump is equipped with a NC 8 Amp
250 V contact allowing this function.
0.3 Sauermann does not accept any responsibility in case of not respect of these recommendation
1. INSTALLATION
Warning: Before carrying out any operation on the pump, make sure the installation is disconnected from
the power supply.
We recommend the pump be positioned with the suction & discharge spigots pointing downward.
Ø Installation with Mounting Bracket supplied (fig. 1)
- Fasten the Mounting Bracket with the screw & rawlplug supplied.
- Slide the pump body onto the bracket.
2. POWER SUPPLY (fig. 2 and 4)
2.1 Connection to power supply
Connect the pump to the power supply using a circuit breaker (not included) to standard IEC 345
on live & neutral.
2.2 Connection for model PE 5000 (Cooling only, compressor signal) (fig. 2)


Produkt Specifikationer

Mærke: Sauermann
Kategori: Pomp
Model: PE-5200

Har du brug for hjælp?

Hvis du har brug for hjælp til Sauermann PE-5200 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Pomp Sauermann Manualer

Sauermann

Sauermann Delta Manual

1 Januar 2025
Sauermann

Sauermann Omega Manual

1 Januar 2025
Sauermann

Sauermann Si-10 Manual

23 August 2024
Sauermann

Sauermann SI-30 Manual

21 August 2024
Sauermann

Sauermann SI-20 Manual

21 August 2024
Sauermann

Sauermann SI-83 Manual

21 August 2024
Sauermann

Sauermann SI-1830 Manual

21 August 2024
Sauermann

Sauermann PE-5200 Manual

21 August 2024

Pomp Manualer

Nyeste Pomp Manualer