SHW610X2 - SHW910X2
1. SAFETY INFORMATION
For your safety and correct
operation of the appliance,
read this manual carefully before
installation and use. Always keep
these instructions with the appli-
ance even if you move or sell it.
Users must fully know the oper-
ation and safety features of the
appliance.
The wire connection has to
be done by specialized tech-
nician.
The manufacturer will not be
held liable for any damages
resulting from incorrect or
improper installation.
The minimum safety distance
between the cooker top and
the extractor hood is 650 mm
(some models can be installed
at a lower height, please refer
to the paragraphs on working
dimensions and installation).
If the instructions for installation
for the gas hob specify a
greater distance, this must be
respected.
Check that the mains voltage
corresponds to that indicated
on the rating plate xed to the
inside of the hood.
Means for disconnection must
be incorporated in the xed
wiring in accordance with the
wiring rules.
For Class I appliances, check
that the domestic power supply
guarantees adequate earthing.
Connect the extractor to the
exhaust ue through a pipe of
minimum diameter 120 mm.
The route of the ue must be
as short as possible.
Regulations concerning the
discharge of air have to be
fullled.
Do not connect the extractor
hood to exhaust ducts carrying
combustion fumes (boilers,
replaces, etc.).
If the extractor is used in
conjunction with non-electrical
appliances (e.g. gas burning
appliances), a sufcient degree
of aeration must be guaranteed
in the room in order to prevent
the backow of exhaust gas.
When the cooker hood is used
in conjunction with appliances
supplied with energy other than
electric, the negative pressure
in the room must not exceed
0,04 mbar to prevent fumes
being drawn back into the room
by the cooker hood.
The air must not be discharged
into a ue that is used for
exhausting fumes from
appliances burning gas or
other fuels.
If the supply cord is damaged,
it must be replaced from the
manufacturer or its service
agent.
Connect the plug to a socket
complying with current
regulations, located in an
accessible place.
EN
2


Produkt Specifikationer

Mærke: Smeg
Kategori: Emhætte
Model: SHW910X2

Har du brug for hjælp?

Hvis du har brug for hjælp til Smeg SHW910X2 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Emhætte Smeg Manualer

Smeg

Smeg KBTU30X Manual

18 Juni 2025
Smeg

Smeg KBTU36X Manual

18 Juni 2025
Smeg

Smeg KPRU24X Manual

17 Juni 2025
Smeg

Smeg KBTU48X Manual

17 Juni 2025
Smeg

Smeg KPRU36X Manual

17 Juni 2025
Smeg

Smeg SH670LSS1 Manual

8 Juni 2025
Smeg

Smeg PUM610X Manual

8 Juni 2025
Smeg

Smeg KSEC61XE3 Manual

6 Marts 2025
Smeg

Smeg KSED95MBL Manual

21 Februar 2025
Smeg

Smeg KSET86LX3 Manual

3 Februar 2025

Emhætte Manualer

Nyeste Emhætte Manualer