Sussex RFMCTSXFMMIK Manual

Sussex Vandhane RFMCTSXFMMIK

Læs gratis den danske manual til Sussex RFMCTSXFMMIK (6 sider) i kategorien Vandhane. Denne vejledning er vurderet som hjælpsom af 3 personer og har en gennemsnitlig bedømmelse på 4.9 stjerner ud af 2 anmeldelser. Har du et spørgsmål om Sussex RFMCTSXFMMIK, eller vil du spørge andre brugere om produktet?

Side 1/6
Tapware is to be installed by a Licensed Plumber in accordance with AS/NZS 3500:2003
Recommended working water pressure 300-500 kpa. Maximum water temperature is 65 deg.c
Copyright © Sussex Taps.
Product code
Circa
Floormount mixer Fixing distances
RFMCT Floormount mixer
RFMBMCT Floormount basin mixer
RFMBMCT-V Floormount basin mixer - Vertex
RFMHT Floormount mixer with hand shower
RFMHT-V Floormount mixer with hand shower - Vertex
sussextaps.com.au
Tapware is to be installed by a Licensed Plumber in accordance with AS/NZS 3500:2003
Recommended working water pressure 300-500 kpa. Maximum water temperature is 65 deg.c
Copyright © Sussex Taps.
Floormount mixer Concrete floor Rough-in
HO T/ COLD
FE E
D CH AN
NEL
Ap p ro x.
400m m
Ap pro x.
400m m
CONCRETE RECES REQUIREMENTS
FIXED AND CONNECTED VALVE BACK FILLED RECESS
FIXINF AND CONNECTIONS
(FIXING VALVE)
Circa
Fixing and connections (Fig. 2 & 3)
Back-filled recess (Fig. 4)
Existing concrete floor
New concrete floor (pre-pour)
*To install the Floormount Fixing Valve a 50mm step down (recess) is required in the concrete surface where
the floormount is to be located.
- The recess area is to be a minimum of 200 x 300mm to allow enough room for the fixing valve to be fitted.
NOTE: This can be a larger area if unsure of exact mounting position.
Important: the recess area is required to be 50mm deep and must be flat and level.
- Connect 1/2” elbows (or male/female nipples) to Fixing Valve in preparation for the hot/cold water lines.
- Postion fixing valve into concreted recess area.
NOTE: Align “Front” to face bath or wash vessel.
- Mark and drill for 8mm “dyna bolt” or other appropriate anchoring bolts (not supplied).
- Fix Floormount Fixing Valve and complete hot and cold water line connections.
- Ensure the valve is level and well anchored.
- Tighten “end caps” and perform water testing, and ensure there are no water leaks.
- Leave end caps, pressure plate and fixing bolts in the valve to protect the threads until final fit-off.
- Once all water connections are made and tested, fill in the recessed area and channelling up to the
Fixing Valve with a mortar mix.
- After mortar has set, seal the area between mortar and the Fixing Valve.
- Cut 400 x 400mm section through concrete slab where the floormount mixer is to be located (Fig. 1).
- Remove cut section and drill for the appropriate concrete ‘tie-rods’ into side walls of cavity.
- Fit ‘tie-rods’ and pour concrete to create a 50mm step down (recess) from the original concrete
floor surface (Fig. 1).
NOTE: Recess area must be flat and level.
- Hot and cold lines can be chased into the recessed area by cutting a minimum 50 x 50mm channel (Fig. 1).
*To install this floormount fixing valve, a 50mm step down (recess) is required in the concrete slab. The floormount fixing
valve is supplied with end caps, pressure plate and fixing bolts. Leave intact until final fit off with the floormount mixer.
sussextaps.com.au


Produkt Specifikationer

Mærke: Sussex
Kategori: Vandhane
Model: RFMCTSXFMMIK

Har du brug for hjælp?

Hvis du har brug for hjælp til Sussex RFMCTSXFMMIK stil et spørgsmål nedenfor, og andre brugere vil svare dig