Installation and operation manual solid fuel fireplace insert
GB
ALICANTE, VALENCIA
tested according to the standard EN 13229
1. Installation manual
1.1 General
Fireplace insert for solid fuel is a single-shaft heating device which replaces the existing heating for short periods between seasons or
supports it in the cold seasons. Fireplace insert is designed for local heating. Fireplace insert can be installed in a normal environment.
This fireplace insert has been tested according the standard EN 13229 with fuels: wood and brown-coal briquettes. This fireplace
insert met the requirements of this standard.
All local regulations, including regulations relating to national and European standards have to be followed when installing the fireplace
insert.
Before mounting the fireplace insert, you have to inform the competent master chimney sweep who will inspect as expert the proper
connection of fireplace insert to the chimney. Fireplace insert must be installed on floorings that have corresponding loading capacity.
By installation, it is necessary to ensure sufficient space for cleaning of fire insert, flue and chimney. The fire insert must be closed
during operation, but also when not in operation, because otherwise it might significantly affect other devices connected to the
chimney.
Combustion chamber is enclosed by sheet metal plate filled from inside with vermiculittes. In the bottom part of the combustion
chamber, there is the bed with cast-iron grate. There is an ash box under the grate. Stokers door are sealed with gasket. The door may
be opened only to add fuel. The stokers door are paned with highly heat-resistant glass-ceramic.
The smallest size of the front opening in the lining of fireplace insert is: width 600 mm and height 750 mm. Surface temperatures of the
lining can reach, depending on thermal resistance coefficient of the used construction material and its thickness, within the range
between 30 and 80°C.
NOTE: when claiming or ordering spare parts always quote the name, type and serial number given on the data card.
1.2 Specifications
Nominal capacity: 8,0 kW
Nominal heating capacity efficiency: wood = 82,3 %, lignite briquettes = 70,5 %
Operating chimney draft: 10 Pa
Height with legs 825 mm
Width
588 mm
Depth ALICANTE = 392 mm, VALENCIA =423 mm
Draught shaft diameter: Ø150 mm
Weight ALICANTE = 63 kg, VALENCIA = 64 kg
Recommended fuel:
- dry hard wood - approximate heating value 15 MJ.kg
-1
- lignite briquettes - approximate heating capacity 20 ÷ 23 MJkg
-1
Approximate consumption of recommended fuel at nominal capacity:
- wood: 2.2 kg.hod.
-1
- lignite briquettes: 1.7 kg.hod.
-1
Heating capacity:
- favourable type of construction: 190 m³
- less favourable type of construction: 145 m³
- unfavourable type of construction: 98
Applicable standards: EN 13229
1.3 Connection to the chimney
At installation comply with all corresponding project, safety and hygienic regulations.
Data to calculate the chimney (at the nominal thermal power):
Fuel Brown-coal briquettes Wood
Flue gas flow [g/s] 10,0 6,1
Max. flue gas temperature behind exhaust throat [°C] 377 312
Min. blast draught at nominal thermal power [Pa] 10 10
The fireplace insert can be used to connect a multi-occupied chimney, which means that to the chimney with the fire insert connected,
we can connect more devices.
Before connecting the fireplace insert, make sure there is sufficient blast in the chimney. Flame of a burning paper or candle should be
sucked into the chimney opening. The fireplace insert should be attached to the chimney flue in the shortest direction.
The fireplace insert should be attached to the chimney flue always with the consent of competent chimney sweeper office in
compliance with STN 73 4210 and STN 73 4201.
If the fireplace insert cannot be attached to the chimney flue directly, the flue involved should be the shortest possible and ascend
towards the chimney. Flues can be of maximum 1,5 m length. In any case, it is necessary to ensure smoke tubes and bends, mounted
on exhaust throat, against getting loose by a pin. Smoke tubes and bends must be attached firm and tight to the fireplace insert and
plugged into each other by minimum 40 mm length in the direction of chimney blast. The chimney opening must be fitted with a sheet
metal case with a diameter corresponding to the diameter of used smoke tubes.
C t d i t ti f fi l i
t t th hi i di l d i Fi 1
ALICANTE / VALENCIA
Incorrect Correct
Figure 1
To ensure a failure-free operation, the chimney blast must be kept at 10 Pa (measured inside of smoke tube behind the fireplace
insert). As the chimney blast can be affected by changeable factors, as the outside air temperature, combustion temperature, chimney
lining, wind power, etc., it varies during the year. Therefore it is recommended to install a damper inside of the chimney.
The fireplace insert can reach the specified performance and efficiency as long as it is connected to a chimney with sufficient blast
draught. The chimney´s cross section must be 150x150 mm, and minimum height 5 meters.
1.4 Space venting
The fireplace insert operation requires sufficient space venting, meaning incoming flow of outside air into the space where the fireplace
insert is operated. That can be done through an open window or open external door. However, it is safer, if together with the installation
of fireplace insert a special opening is made in the external wall, in the area where fireplace insert is mounted, in order to ensure
sufficient incoming air flow for combustion. Adjustable ventilation grille, opened and closed from inside, should be embedded in the
opening. The fireplace insert needs for wood combustion up to 20 m
3
of fresh air per hour.
Insufficient air flow runs counter to proper operation of fireplace inserts and is a threat to your safety!
Let the installation of your fireplace insert, its connection to chimney and venting be tested by a competent chimney sweep in
your area!
1.5 Fire safety
It is obligatory to strictly adhere to the rules of fire safety covered by STN 92 0300.
In case of nearby flammable building material or objects with combustibility degree B, C1 and C2 according to STN 73 0823, place the
fireplace insert with appropriate flue at safe distance which is at minimum 400 mm from these objects.
Safe distance should be doubled if the fireplace insert with flue was standing close to material with the combustibility degree C3. The
same applies if the degree of combustibility for the material cannot be proved.
Safe distance can be decreased to half in case of using a nonflammable, heat-insulating shading board, min. 5 mm thick, placed in
such a way there is 25 mm gap left between the board and the protected flammable object.
If the flooring is made of flammable material, place the fireplace insert on nonflammable, heat-insulating pad with dimensions
exceeding the contour of fireplace insert by 300 mm in the front and by 100 mm on all other sides. The smallest dimensions of the pad
and the location method are displayed in Figure 2. Shading board placed on the protected object must exceed the contour of fireplace
insert, including the smoke tubes, by at least 150 mm on each side and at least 300 mm above the upper area.
In case of fire in chimney follow the fire safety rules.
Safe distance between the outer skin of fireplace insert (on sides and behind) and the internal wall of backing must be at least 10 cm.
Minimum dimensions of air intake of interior air are 20x20 cm.
Minimum dimensions of exhaust outlet of heated air are double the size of air intake.
The fireplace insert lining must be of fireproof material.
2. Operation manual
2.1 Important safety instructions
In case of conditions leading to danger of temporarily present flammable gases or when there is a danger of fire or explosion (e.g.
bonding of floor coverings), the fireplace insert must be shut off before the danger arises.
The fireplace insert must be operated according to this manual. It can be only operated by adult persons; it is unacceptable to leave
children close to the fireplace insert in operation.
No flammable liquids can be used to heat up.
IT IS FORBIDDEN TO INCREASE THE NOMINAL THERMAL POWER OF THE FIREPLACE INSERT USING FLAMMABLE
LIQUIDS.
The fireplace insert cannot be operated with stoker door open.
Ash has to be disposed of carefully, and placed in nonflammable containers with cover; hot ash cannot be placed in ash bins or kept in
open air.
Damaged or nonoperational fireplace insert cannot be used. The user must provide its professional repair before using it again.
Ash accumulation in smoke tubes and bends must be checked at least once a month and cleaning provided when required.
During operation, all air supplies to fireplace insert must not be closed.