Læs gratis den danske manual til Velleman DVM6013 (13 sider) i kategorien Multimeter. Denne vejledning er vurderet som hjælpsom af 21 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 11 anmeldelser. Har du et spørgsmål om Velleman DVM6013, eller vil du spørge andre brugere om produktet?

Side 1/13
DVM6013 VELLEMAN 1
DVM6013 – DIGITAL CAPACITANCE METER
1. General
a) Introduction
Thank you for buying the DVM6013. This digital capacitance meter gives a direct reading of capacitance on a 3 ½-
digit LCD display. Nine ranges provide precise readings from 0.1pF to 20mF, which includes virtually all capacitors
used in maintenance services, schools, etc. The DVM6013’s limited weight and small size make it a user-friendly
device.
b) Features
LCD display with character height 21mm, 1999 counts.
9 ranges from 200pF to 20mF
very accurate measurements
external zero adjuster : ±20pF
dual-slope integration A/D converter
overload indication : “1
safe test probes
dimensions : 31.5 x 91 x 189mm (H x W x L)
weight : 240g (battery included)
2. Specifications
Maximum accuracy is achieved during a one-year period after calibration. Ideal circumstances require an operating
temperature of 18 to 28°C (64 to 82°F).
Power Supply 9V-battery NEDA1604 or 6F22 006P
Battery-Low Indication the “ ” symbol is displayed
Fuse 200mA/250V
Excitation Voltage 2.8V peak MAX
Operating Temperature 0 to +40°C (+32 to +10F)
Storage Temperature -10 to +50°C (+14 to +122°F)
Range Resolution Accuracy Test Frequency
200pF 0.1pF ± 0.5% of full scale ± 1 digit 800Hz
2nF 1pF ± 0.5% of full scale ± 1 digit 800Hz
20nF 10pF ± 0.5% of full scale ± 1 digit 800Hz
200nF 100pF ± 0.5% of full scale ± 1 digit 800Hz
2 F µ1000pF ± 0.5% of full scale ± 1 digit 800Hz
20 F µ0.01µ F ± 0.5% of full scale ± 1 digit 80Hz
200 F µ0. F ± 0.5% of full scale ± 1 digit 8Hz
2000 F µ1µF ± 1.0% of full scale ± 1 digit 8Hz
20mF 10µ F ± 2.0% of full scale ± 2 digits 8Hz
DVM6013 VELLEMAN 2
3. Front Panel Description
1. LCD display
2. rotary switch
3. zero adjuster
4. input jacks
4. Operating Instructions
WARNING
Make sure that the battery is correctly inserted into the battery compartment and connected to the battery snaps.
Observe the polarity indications when connecting polarised capacitors. Discharge all capacitors fully.
Do not apply any voltage to the test jacks because serious damage may ensue.
Do not short the test leads together as this will increase the battery’s power consumption drastically. The LCD will
display an overrange indication for all ranges.
OPERATION
If no capacitance value is displayed : start with the 200pF-range and select the next range until the overrange
indication is replaced by an actual measured value.
A shorted capacitor generates an overrange indication on all ranges. A capacitor with a low leakage voltage will
generate either an overrange indication or an unusually high measured value. With an open capacitor, the display
will read “0” for every range (possibly just a few pF for the 200pF-range).
Measure very low capacitances using very short leads or the capacitor-measuring socket above the input jacks on
the front panel. This will allow you to avoid introducing any stray capacitance.
When using the optional test leads to measure small values, you should keep in mind that the leads may
introduce a small capacitive charge. Connect the leads and check the display. Subtract the displayed value from
the eventual measuring result. Obviously, it would be easier to use the zero adjuster on the front panel…
Capacitors, and electrolytic capacitors in particular, are notorious for their great tolerance. You should not be
surprised, therefore, if the measured value is higher than the value on the capacitor, unless when using a
capacitor with low tolerance. However, only on the rarest of occasions will the measured value be much lower
than the rated value.
You can locate a leaking capacity if the value changes considerably when you select a different scale. The effect
of the internal leakage resistance is limited in the lower ranges.


Produkt Specifikationer

Mærke: Velleman
Kategori: Multimeter
Model: DVM6013

Har du brug for hjælp?

Hvis du har brug for hjælp til Velleman DVM6013 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Multimeter Velleman Manualer

Velleman

Velleman VTTEST11N Manual

4 December 2024
Velleman

Velleman DVM852 Manual

5 Oktober 2024
Velleman

Velleman DVM840 Manual

4 Oktober 2024
Velleman

Velleman DVM831 Manual

22 September 2024
Velleman

Velleman DVM870 Manual

2 September 2024
Velleman

Velleman VTTEST23 Manual

27 August 2024
Velleman

Velleman EMDIN03 Manual

22 August 2024
Velleman

Velleman DVM821 Manual

8 August 2024
Velleman

Velleman DVM894 Manual

8 August 2024
Velleman

Velleman DVM68 Manual

7 August 2024

Multimeter Manualer

Nyeste Multimeter Manualer

Draper

Draper 52320 Manual

8 Juni 2025
VOREL

VOREL 81780 Manual

7 Juni 2025
Brymen

Brymen BM878 Manual

7 Juni 2025
Brymen

Brymen BM789 Manual

6 Juni 2025
Draper

Draper 16232 Manual

6 Juni 2025
Draper

Draper 41822 Manual

6 Juni 2025
Draper

Draper 41820 Manual

6 Juni 2025
Brymen

Brymen BM805s Manual

6 Juni 2025
Brymen

Brymen BM785 Manual

6 Juni 2025
Brymen

Brymen BM239R Manual

3 Juni 2025