PACKAGE CONTENTS
FRONT BACK
Control Panel
Front Panel
Air Outlet
Vent
Handle
Power Plug
(1) Pre-Filter
(1) Washable AOC™ Carbon Filter
(1) True HEPA Filter
Unit User Manual
WHERE TO USE
MODEL PART DIAGRAM
12~18 in
12~18 in
Allow 12 ~ 18 in. of space between TVs, radios, and other electronics
Electromagnetic interference from certain electronics may cause
product malfunction.
Place indoors away from direct sunlight
Direct exposure may cause product malfunction or failure.
Only place on hard, flat surfaces
Flimsy or slanted surfaces may result in abnormal noise and vibrations.
Allow 12 ~ 18 in. from walls for maximum air flow
01. Auto Mode Indicator
The LED "Auto" light will indicate when Auto Mode is
activated.
02. Air Quality Indicator
Color coded LED light indicates one of three levels of
Air Quality: Red (poor), Amber (fair), and Blue (good).
03. Fan Speed Indicator
Indicates the current fan speed.
Auto Mode Low Medium
High Turbo
04. PlasmaWave
®
Indicator
Indicates whether PlasmaWave
®
is enabled or
disabled.
05. Sleep Mode Indicator
When Sleep Mode is activated, the Air Quality
Indicator LED light is disabled.
Fan speed will automatically set to minimum speed
(lower than 'Low') which will be nearly silent.
When Sleep Mode is active, PlasmaWave
®
will be
disabled, but it can be turned back on.
06. Filter Replacement Indicator
LED light indicates when it is time to change the filter.
CONTROL PANEL
07. Filter Reset Button
After replacing the True HEPA Filter, use a small object
such as a paper clip, to press and hold the Filter
Reset Button for at least 5 seconds until the Filter
Replacement Indicator turns off.
08. Smart Sensor
Detects the amount of odorous gas in the
environment. When in Auto mode, the fan speed
adjusts according to the detected amount of gas.
09. Power Button
Turns the unit on or off. During the first 30 seconds
of powering up, the Air Quality Indicator will cycle
through Blue, Amber and Red colors.
6PDUW6HQVRUWDNHVDSSUR[LPDWHO\bPLQXWHVWR
detect the air quality in the environment before
normal operation begins.
10. Mode Button
Press to cycle through to set the mode of operation
(Auto, Sleep). The unit will default to Auto with
PlasmaWave
®
enabled when first powered on.
Auto Mode:
Auto Mode automatically adjusts fan speeds
according to your indoor air quality. The fan speed
will adjust to low when air quality is good, medium
when fair, and to high when poor.
Sleep Mode:
When Sleep Mode is activated, the Air Quality
Indicator LED light is disabled.
Fan speed will automatically set to minimum speed
(lower than 'Low') which will be nearly silent.
When Sleep Mode is active, PlasmaWave
®
will be
disabled, but it can be turned back on.
11. PlasmaWave
®
Button
Press the Plasmawave
®
button when the unit is on to
enable or disable this feature. By default,
PlasmaWave
®
is enabled whenever the unit is
powered on.
"When the unit is running, you may hear a chirping
or buzzing sound. The sound is from large particles
passing through PlasmaWave
®
, it is normal and does
not signify product failure."
12. Light Sensor
Detects the amount of ambient light in the
environment. When in Auto Mode, the Light Sensor
detects when to put the unit into Sleep Mode.
When to Replace Filters
Filter Indicator Light When to Service When to Replace
Pre-Filter
none Clean once every 14 days Permanent
Washable AOC™
Carbon Filter
none
* Clean once every
3 months
Lasts Approx. 12 months
True HEPA Filter
Can NOT be WASHED
When the Check Filter Indicator LED is on, it is time to replace the True HEPA Filter and Washable AOC™ Carbon Filter.
Intervals between filter replacement may vary depending on environment.
* Filter performance may decrease after each wash and depending on contamination level prior to washing.
MAINTENANCE
3
True HEPA Filter
2
Washable AOC™
Carbon Filter
4
PlasmaWave
®
Pre-Filter
1
4-STAGE AIR PURIFICATION
01. Pre-Filter
Designed to catch larger airborne particles found
indoors.
03. True HEPA Filter
Winix True HEPA captures 99.99%* of airborne allergens
including pollen, dust, smoke, pet dander, and other
ultrafine particles as small as 0.003 microns. *Based on
independent laboratory tests conducted on inanimate
particles as small as 0.003 microns.
02. Washable AOC™ Carbon Filter
Reduces VOCs and household odors from cooking,
pets, and smoke.
04. PlasmaWave
®
Winix PlasmaWave
®
Technology may help to reduce
airborne contaminants*.
*Tested by an independent third-party laboratory.
Visit www.winixamerica.com for more details.
INITIAL OPERATION
Latch
1. Remove the front panel by grasping its upper
edge and gently pulling forward.
2. Remove the Pre-Filter, then the bag of filters
behind it.
3. Remove filters from protective plastic bag.
4. Install the filters until they fit securely in place.
03. True HEPA Filter (back)
02. Washable AOC™ Carbon Filter (middle)
01. Pre-Filter (front)
Latch
5. After filters are installed, close the front panel.
6. Insert the power cord into an electrical outlet.
Resetting Filter Life:
After replacing your True HEPA Filter, place
the Pre-Filter back in and close the Front
Panel. While the unit is on, use a small, thin
object (such as a paperclip) to hold the Filter
Reset Button for at least 5 seconds until
you hear the beep. After the beep, the Filter
Replacement Indicator will disappear.
Your Winix True HEPA is now reset.
REPLACING FILTERS
CLEANING CARE
Cleaning the Filters:
Use a vacuum cleaner or soft brush to clean the Pre-
Filter
If it is excessively soiled, rinse in room temperature water.
Do not use detergent or soap.
Allow the filter to dry for 24 hours or more before using.
Intervals between filter cleaning may vary depending
on the air quality in the environment.
To clean the Washable AOC™ Carbon Filter, remove
from unit and rinse under lightly running room
temperature water.
Do not use detergent or soap.
Allow the filter to dry for 24 hours or mote before using.
Do not use hot water over 104
o
F.
NOTICE
Do not use benzene, alcohol, or other volatile fluids,
which may cause damage or discoloration.
Cleaning the Exterior & Interior:
Wipe with a soft damp cloth using room temperature
water.
Afterwards, wipe it down with a clean, dry cloth.
Open the front panel and clean the interior with a
vacuum cleaner.
)RURSWLPDOSHUIRUPDQFHFOHDQHYHU\bbPRQWKV
NOTICE
When cleaning the unit, always unplug the power cord
first and then wait until the unit has cooled down.
Never disassemble, repair, or modify this unit
yourself.
Do not use flammable sprays or liquid detergents.
Do not allow children to clean or maintain the unit.
Before cleaning or maintaining, ensure unit is
unplugged.


Produkt Specifikationer

Mærke: Winix
Kategori: Luftrenser
Model: AM80

Har du brug for hjælp?

Hvis du har brug for hjælp til Winix AM80 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Luftrenser Winix Manualer

Winix

Winix WACP300 Manual

23 September 2025
Winix

Winix P300 Manual

22 September 2025
Winix

Winix AUS-1250A850 Manual

22 September 2025
Winix

Winix HR1000 Manual

22 September 2025
Winix

Winix P150 Manual

22 September 2025
Winix

Winix 5300-2 Manual

22 September 2025
Winix

Winix Zero N Manual

21 September 2025
Winix

Winix AM80 Manual

21 September 2025
Winix

Winix 9800 Manual

21 September 2025

Luftrenser Manualer

Nyeste Luftrenser Manualer